25 research outputs found

    Feasibility of ex vivo fluorescence imaging of angiogenesis in (non-) culprit human carotid atherosclerotic plaques using bevacizumab-800CW

    Get PDF
    Vascular endothelial growth factor-A (VEGF-A) is assumed to play a crucial role in the development and rupture of vulnerable plaques in the atherosclerotic process. We used a VEGF-A targeted fluorescent antibody (bevacizumab-IRDye800CW [bevacizumab-800CW]) to image and visualize the distribution of VEGF-A in (non-)culprit carotid plaques ex vivo. Freshly endarterectomized human plaques (n = 15) were incubated in bevacizumab-800CW ex vivo. Subsequent NIRF imaging showed a more intense fluorescent signal in the culprit plaques (n = 11) than in the non-culprit plaques (n = 3). A plaque received from an asymptomatic patient showed pathologic features similar to the culprit plaques. Cross-correlation with VEGF-A immunohistochemistry showed co-localization of VEGF-A over-expression in 91% of the fluorescent culprit plaques, while no VEGF-A expression was found in the non-culprit plaques (p < 0.0001). VEGF-A expression was co-localized with CD34, a marker for angiogenesis (p < 0.001). Ex vivo near-infrared fluorescence (NIRF) imaging by incubation with bevacizumab-800CW shows promise for visualizing VEGF-A overexpression in culprit atherosclerotic plaques in vivo

    Identification and Validation of Esophageal Squamous Cell Carcinoma Targets for Fluorescence Molecular Endoscopy

    Get PDF
    Dysplasia and intramucosal esophageal squamous cell carcinoma (ESCC) frequently go unnoticed with white-light endoscopy and, therefore, progress to invasive tumors. If suitable targets are available, fluorescence molecular endoscopy might be promising to improve early detection. Microarray expression data of patient-derived normal esophagus (n = 120) and ESCC samples (n = 118) were analyzed by functional genomic mRNA (FGmRNA) profiling to predict target upregulation on protein levels. The predicted top 60 upregulated genes were prioritized based on literature and immunohistochemistry (IHC) validation to select the most promising targets for fluorescent imaging. By IHC, GLUT1 showed significantly higher expression in ESCC tissue (30 patients) compared to the normal esophagus adjacent to the tumor (27 patients) (p n = 17) and high-grade dysplasia (HGD, n = 13) is higher (p n = 7) and to the normal esophagus adjacent to the tumor (n = 5). The sensitivity and specificity of 2-DG 800CW to detect HGD and ESCC is 80% and 83%, respectively (ROC = 0.85). We identified and validated GLUT1 as a promising molecular imaging target and demonstrated that fluorescent imaging after topical application of 2-DG 800CW can differentiate HGD and ESCC from LGD and normal esophagus

    Fluorescence-Guided Visualization of Soft-Tissue Sarcomas by Targeting Vascular Endothelial Growth Factor A:A Phase 1 Single-Center Clinical Trial

    Get PDF
    Resection of soft-tissue sarcoma (STS) is accompanied by a high rate of tumor-positive surgical margins (14%-34%), which potentially lead to decreased disease-free survival. Vascular endothelial growth factor A is overexpressed in malignant tumors, including STS, and can be targeted with bevacizumab-800CW during fluorescence-guided surgery for real-time tumor detection. In this phase 1 clinical trial, we determined the feasibility, safety, and optimal dose of bevacizumab-800CW for fluorescence-guided surgery in STS for in vivo and ex vivo tumor detection. Methods: Patients with a histopathologic diagnosis of STS were included. In the dose-escalation phase, patients received bevacizumab-800CW intravenously 3 d before surgery (10, 25, and 50 mg; n = 8). In the subsequent dose-expansion phase, 7 additional patients received bevacizumab800CW at the optimal dose. Fluorescence images were obtained in vivo and ex vivo during all stages of standard care. The optimal dose was determined by calculating in vivo and ex vivo tumor-to-background ratios (TBR) and correlating these results with histopathology. Results: Fifteen patients with STS completed this study. All tumors could be visualized during in vivo and ex vivo imaging. The optimal bevacizumab-800CW dose proved to be 10 mg, with a median in vivo TBR of 2.0 (+/- 0.58) and a median ex vivo TBR of 2.67 (+/- 1.6). All 7 tumor-positive margins could be observed in real time after surgical resection. Conclusion: GS using 10 mg of bevacizumab-800CW is feasible and safe for intraoperative imaging of STS, potentially allowing tumor detection and margin assessment during surgery. An additional follow-up phase 2 study is needed to confirm the diagnostic accuracy

    Back-Table Fluorescence-Guided Imaging for Circumferential Resection Margin Evaluation Using Bevacizumab-800CW in Patients with Locally Advanced Rectal Cancer

    Get PDF
    Negative circumferential resection margins (CRM) are the cornerstone for the curative treatment of locally advanced rectal cancer (LARC). However, in up to 18.6% of patients, tumor-positive resection margins are detected on histopathology. In this proof-of-concept study, we investigated the feasibility of optical molecular imaging as a tool for evaluating the CRM directly after surgical resection to improve tumor-negative CRM rates. Methods: LARC patients treated with neoadjuvant chemoradiotherapy received an intravenous bolus injection of 4.5 mg of bevacizumab-800CW, a fluorescent tracer targeting vascular endothelial growth factor A, 2-3 d before surgery (ClinicalTrials.gov identifier: NCT01972373). First, for evaluation of the CRM status, back-table fluorescence guided imaging (FGI) of the fresh surgical resection specimens (n = 8) was performed. These results were correlated with histopathology results. Second, for determination of the sensitivity and specificity of bevacizumab-800CW for tumor detection, a mean fluorescence intensity cutoff value was determined from the formalin-fixed tissue slices (n = 42; 17 patients). Local bevacizumab-800CW accumulation was evaluated by fluorescence microscopy. Results: Back-table FGI correctly identified a tumor-positive CRM by high fluorescence intensities in 1 of 2 patients (50%) with a tumor-positive CRM. For the other patient, low fluorescence intensities were shown, although (sub)millimeter tumor deposits were present less than 1 mm from the CRM. FGI correctly identified 5 of 6 tumor-negative CRM (83%). The 1 patient with false-positive findings had a marginal negative CRM of only 1.4 mm. Receiver operating characteristic curve analysis of the fluorescence intensities of formalin-fixed tissue slices yielded an optimal mean fluorescence intensity cutoff value for tumor detection of 5,775 (sensitivity of 96.19% and specificity of 80.39%). Bevacizumab-800CW enabled a clear differentiation between tumor and normal tissue up to a microscopic level, with a tumor-to-background ratio of 4.7 +/- 2.5 (mean SD). Conclusion: In this proof-of-concept study, we showed the potential of back-table FGI for evaluating the CRM status in LARC patients. Optimization of this technique with adaptation of standard operating procedures could change perioperative decision making with regard to extending resections or applying intraoperative radiation therapy in the case of positive CRM

    Noninvasive optical and nuclear imaging of Staphylococcus-specific infection with a human monoclonal antibody-based probe

    Get PDF
    Staphylococcus aureus infections are a major threat in healthcare, requiring adequate early-stage diagnosis and treatment. This calls for novel diagnostic tools that allow noninvasive in vivo detection of staphylococci. Here we performed a preclinical study to investigate a novel fully-human monoclonal antibody 1D9 that specifically targets the immunodominant staphylococcal antigen A (IsaA). We show that 1D9 binds invariantly to S. aureus cells and may further target other staphylococcal species. Importantly, using a human post-mortem implant model and an in vivo murine skin infection model, preclinical feasibility was demonstrated for 1D9 labeled with the near-infrared fluorophore IRDye800CW to be applied for direct optical imaging of in vivo S. aureus infections. Additionally, (89)Zirconium-labeled 1D9 could be used for positron emission tomography imaging of an in vivo S. aureus thigh infection model. Our findings pave the way towards clinical implementation of targeted imaging of staphylococcal infections using the human monoclonal antibod

    Potential red-flag identification of colorectal adenomas with wide-field fluorescence molecular endoscopy

    Get PDF
    Adenoma miss rates in colonoscopy are unacceptably high, especially for sessile serrated adenomas / polyps (SSA/Ps) and in high-risk populations, such as patients with Lynch syndrome. Detection rates may be improved by fluorescence molecular endoscopy (FME), which allows morphological visualization of lesions with high-definition white-light imaging as well as fluorescence-guided identification of lesions with a specific molecular marker. In a clinical proof-of-principal study, we investigated FME for colorectal adenoma detection, using a fluorescently labelled antibody (bevacizumab-800CW) against vascular endothelial growth factor A (VEGFA), which is highly upregulated in colorectal adenomas. Methods: Patients with familial adenomatous polyposis (n = 17), received an intravenous injection with 4.5, 10 or 25 mg of bevacizumab-800CW. Three days later, they received NIR-FME. Results: VEGFA-targeted NIR-FME detected colorectal adenomas at all doses. Best results were achieved in the highest (25 mg) cohort, which even detected small adenomas ( < 3 mm). Spectroscopy analyses of freshly excised specimen demonstrated the highest adenoma-to-normal ratio of 1.84 for the 25 mg cohort, with a calculated median tracer concentration in adenomas of 6.43 nmol/mL. Ex vivo signal analyses demonstrated NIR fluorescence within the dysplastic areas of the adenomas. Conclusion: These results suggest that NIR-FME is clinically feasible as a real-time, red-flag technique for detection of colorectal adenomas

    Potential Red-Flag Identification of Colorectal Adenomas with Wide-Field Fluorescence Molecular Endoscopy

    Get PDF
    Adenoma miss rates in colonoscopy are unacceptably high, especially for sessile serrated adenomas/polyps (SSA/Ps) and in high-risk populations, such as patients with Lynch syndrome. Detection rates may be improved by fluorescence molecular endoscopy (FME), which allows morphological visualization of lesions with high-definition white-light imaging as well as fluorescence-guided identification of lesions with a specific molecular marker. In a clinical proof-of-principal study, we investigated FME for colorectal adenoma detection, using a fluorescently labelled antibody (bevacizumab-800CW) against vascular endothelial growth factor A (VEGFA), which is highly upregulated in colorectal adenomas. Methods: Patients with familial adenomatous polyposis (n = 17), received an intravenous injection with 4.5, 10 or 25 mg of bevacizumab-800CW. Three days later, they received NIR-FME. Results: VEGFA-targeted NIR-FME detected colorectal adenomas at all doses. Best results were achieved in the highest (25 mg) cohort, which even detected small adenomas ( Conclusion: These results suggest that NIR-FME is clinically feasible as a real-time, red-flag technique for detection of colorectal adenomas

    Implementation and benchmarking of a novel analytical framework to clinically evaluate tumor-specific fluorescent tracers

    Get PDF
    During the last decade, the emerging field of molecular fluorescence imaging has led to the development of tumor-specific fluorescent tracers and an increase in early-phase clinical trials without having consensus on a standard methodology for evaluating an optical tracer. By combining multiple complementary state-of-the-art clinical optical imaging techniques, we propose a novel analytical framework for the clinical translation and evaluation of tumor-targeted fluorescent tracers for molecular fluorescence imaging which can be used for a range of tumor types and with different optical tracers. Here we report the implementation of this analytical framework and demonstrate the tumor-specific targeting of escalating doses of the near-infrared fluorescent tracer bevacizumab-800CW on a macroscopic and microscopic level. We subsequently demonstrate an 88% increase in the intraoperative detection rate of tumor-involved margins in primary breast cancer patients, indicating the clinical feasibility and support of future studies to evaluate the definitive clinical impact of fluorescence-guided surgery

    Tumor-specific uptake of fluorescent bevacizumab-IRDye800CW microdosing in patients with primary breast cancer:a phase I feasibility study

    Get PDF
    PURPOSE: to provide proof of principle of safety, breast tumor-specific uptake and positive tumor margin assessment of the systemically administered near-infrared fluorescent (NIRF) tracer bevacizumab-IRDye800CW targeting vascular endothelial growth factor (VEGF)-A in breast cancer patients. EXPERIMENTAL DESIGN: Twenty patients with primary invasive breast cancer eligible for primary surgery received 4.5 mg bevacizumab-IRDye800CW as intravenous bolus injection. Safety aspects were assessed as well as tracer uptake and tumor delineation during surgery and ex vivo in surgical specimens using an optical imaging system. Ex vivo multiplexed histopathology analyses were performed for evaluation of biodistribution of tracer uptake and co-registration of tumor tissue and healthy tissue. RESULTS: None of the patients experienced adverse events. Tracer levels in primary tumor tissue were higher compared to those in the tumor margin (P < 0.05) and healthy tissue (P < 0.0001). VEGF-A tumor levels also correlated with tracer levels (r = 0.63, P < 0.0002). All but one tumor showed specific tracer uptake. Two out of 20 surgically excised lumps contained microscopic positive margins detected ex vivo by fluorescent macro- and microscopy and confirmed at the cellular level. CONCLUSIONS: Our study shows that systemic administration of the bevacizumab-IRDye800CW tracer is safe for breast cancer guidance and confirms tumor and tumor-margin uptake as evaluated by a systematic validation methodology. The findings are a step towards a phase II dose-finding study aimed at in vivo margin assessment and point to a novel drug assessment tool that provides a detailed picture of drug distribution in tumor tissue
    corecore