66 research outputs found

    Long-term outcome and chest pain in patients with true versus non-true bifurcation lesions treated with second-generation drug-eluting stents in the TWENTE trial

    Get PDF
    The objective of this study is to assess 3-year clinical outcome of patients with true bifurcation lesions (TBLs) versus non-true bifurcation lesions (non-TBLs) following treatment with second-generation drug-eluting stents (DES). TBLs are characterized by the obstruction of both main vessel and side-branch. Limited data are available on long-term clinical outcome following TBL treatment with newer-generation DES. We performed an explorative sub-study of the randomized TWENTE trial among 287 patients who had bifurcated target lesions with side-branches ≄2.0 mm. Patients were categorized into TBL (Medina classes: 1.1.1; 1.0.1; 0.1.1) versus non-TBL to compare long-term clinical outcome. A total of 116 (40.4 %) patients had TBL, while 171 (59.6 %) had non-TBL only. Target-lesion revascularization rates were similar (3.5 vs. 3.5 %; p = 1.0), and definite-or-probable stent thrombosis rates were low (both <1.0 %). The target-vessel myocardial infarction (MI) rate was 11.3 versus 5.3 % (p = 0.06), mostly driven by (periprocedural) MI ≀48 h from PCI. All-cause mortality and cardiac death rates were 8.7 versus 3.5 % (p = 0.06) and 3.5 versus 1.2 % (p = 0.22), respectively. The 3-year major adverse cardiac event rate for patients with TBL versus non-TBL was 20.0 versus 11.7 % (p = 0.05). At 1-, 2-, and 3-year follow-up, 6.5, 13.0, and 11.0 % of patients reported chest pain at less than or equal moderate physical effort, respectively, without any between-group difference. Patients treated with second-generation DES for TBL had somewhat higher adverse event rates than patients with non-TBL, but dissimilarities did not reach statistical significance. Up to 3-year follow-up, the vast majority of patients of both groups remained free from chest pain

    High Bleeding Risk Patients Treated with Very Thin-Strut Biodegradable Polymer or Thin-Strut Durable Polymer Drug-Eluting Stents in the BIO-RESORT Trial

    Get PDF
    Purpose: Patients with high bleeding risk (HBR) who undergo percutaneous coronary intervention also have an increased risk of ischemic events and represent an overall high-risk population. The coating of durable polymer drug-eluting stents (DP-DES) may induce inflammation and delay arterial healing, which might be reduced by novel biodegradable polymer DES (BP-DES). We aimed to evaluate the safety and efficacy of treating HBR patients with very thin-strut BP-DES versus thin-strut DP-DES. Methods: Participants in BIO-RESORT (NCT01674803), an investigator-initiated multicenter, randomized all-comers trial, were treated with very thin-strut BP-DES (Synergy or Orsiro) or thin-strut DP-DES (Resolute Integrity). For the present analysis, patients were classified following HBR criteria based on previous trials. The primary endpoint was target vessel failure: a composite of cardiac death, target vessel-related myocardial infarction, or target vessel revascularization at 1 year. Results: Of all 3514 patients, 1009 (28.7%) had HBR. HBR patients were older (p < 0.001) and had more co-morbidities than non-HBR patients (p < 0.001). At 1-year follow-up, HBR patients had significantly higher rates of target vessel failure (6.7 vs. 4.2%, p = 0.003), cardiac death (1.9 vs. 0.4%, p < 0.001), and major bleeding (3.3 vs. 1.5%, p = 0.001). Of all 1009 HBR patients, 673 (66.7%) received BP-DES and 336 (33.3%) had DP-DES. The primary endpoint was met by 43/673 (6.5%) patients treated with BP-DES and 24/336 (7.3%) treated with DP-DES (HR 0.88 [95%CI 0.54–1.46], p = 0.63). There were no significant between-group differences in the most global patient-oriented clinical endpoint (9.7 vs. 10.5%, HR 0.92 [95%CI 0.61–1.39], p = 0.69) and other secondary endpoints. Conclusions: At 1-year follow-up, very thin-strut BP-DES showed similar safety and efficacy for treating HBR patients as thin-strut DP-DES

    Impact of sex-specific target dose in chronic heart failure patients with reduced ejection fraction

    Get PDF
    Aims A recent study suggested that women with heart failure and heart failure reduced ejection fraction might hypothetically need lower doses of angiotensin-converting enzyme inhibitors or angiotensin II receptor blockers ( = renin-angiotensin-system inhibitors) and beta-blockers than men to achieve the best outcome. We assessed the current medical treatment of heart failure reduced ejection fraction in men and women in a large contemporary cohort and address the hypothetical impact of changing treatment levels in women. Methods This analysis is part of a large contemporary quality of heart failure care project which includes 5320 (64%) men and 3003 (36%) women with heart failure reduced ejection fraction. Detailed information on heart failure therapy prescription and dosage were collected. Results Women less often received renin-angiotensin-system inhibitors (79% vs 83%, p 100% of the new hypothetical target dose would be 24% for beta-blockers and 52% for renin-angiotensin-system inhibitors, which can be considered as relatively overdosed. Conclusion In this large contemporary heart failure registry, there were significant but relatively small differences in drug dose between men and women with heart failure reduced ejection fraction. Implementation of the hypothetical sex-specific target dosing schedule would lead to considerably more women adequately treated. In contrast, we identified a group of women who might have been relatively overdosed with increased risk of side-effects and intolerance

    Bioresorbable Polymer-Coated Orsiro Versus Durable Polymer-Coated Resolute Onyx Stents (BIONYX):Rationale and design of the randomized TWENTE IV multicenter trial

    Get PDF
    Aim: The aim was to compare in a noninferiority trial the efficacy and safety of 2 contemporary drug-eluting stents (DESs): a novel, durable polymer-coated stent versus an established bioabsorbable polymer-coated stent. Methods and results: The BIONYX trial (ClinicalTrials.gov-no.NCT02508714) is an investigator-initiated, prospective, randomized, patient- and assessor-blinded, international, multicenter study in all-comer patients with all types of clinical syndromes and lesions who require percutaneous coronary interventions with DES. Patients at 7 study sites in the Netherlands, Belgium, and Israel were randomly assigned (1:1, stratified for gender and diabetes mellitus) to treatment with the novel, zotarolimus-eluting, durable polymer-coated Resolute Onyx stent that has a radiopaque, thin-strut, CoreWire stent platform versus the sirolimus-eluting, bioresorbable polymer-coated Orsiro stent (reference device) that has a very thin-strut, cobalt-chromium stent backbone. The primary end point is the 1-year incidence of the composite clinical end point target vessel failure consisting of cardiac death, target vessel–related myocardial infarction, or clinically indicated target vessel revascularization. A power calculation, assuming a target vessel failure rate of 6.0% (noninferiority margin 2.5%), revealed that 2,470 study patients would give the study 80% power (α level 5%), allowing for up to 3% loss to follow-up. The first patient was enrolled on October 7, 2015; on December 23, 2016, the last patient entered the study. Conclusions: BIONYX is a large-scale, prospective, randomized, international, multicenter trial comparing a novel DES with durable coating versus a reference DES with biodegradable coating in all-comers. The study is the first randomized assessment of the Resolute Onyx stent, which is an often-used DES outside the United States

    Bifurcation treatment with novel, highly flexible drug-eluting coronary stents in all-comers: 2-year outcome in patients of the DUTCH PEERS trial

    Get PDF
    Background: Percutaneous coronary intervention (PCI) in bifurcated lesions with second-generation drug-eluting stents (DES) was associated with increased myocardial infarction (MI) rates. Flexible stent designs that accommodate well to vessel tapering may be of benefit in challenging anatomies such as bifurcated target lesions, but so far data are scarce.Methods: We analyzed the 2-year follow-up data of the DUTCH PEERS (TWENTE II) trial, which randomized 1811 all-comer patients to PCI with newer generation resolute integrity zotarolimus-eluting (Medtronic) or promus element everolimus-eluting stents (Boston Scientific). In bifurcated lesions, provisional stenting was generally performed. Target vessel failure is a composite endpoint, consisting of cardiac death, target vessel MI, or target vessel revascularization.Results: Patients with at least one bifurcated lesion (n = 465, 25.7 %) versus patients with non-bifurcated target lesions only (n = 1346, 74.3 %) showed similar rates of clinical endpoints including target vessel failure (9.2 versus 7.9 %, p = 0.36) and definite stent thrombosis (0.4 versus 1.0 %, p = 0.38). Target vessel MI was more common in patients with bifurcated lesions (3.4 versus 1.6 %, p = 0.02); but after multivariate analysis with propensity score adjustment, bifurcation treatment was found not to be an independent predictor of target vessel MI (HR 1.40, 95 % CI 0.71–2.76; p = 0.34). Among patients with bifurcated lesions, DES type and side-branch size did not affect outcome, but periprocedural MI occurred more often after two-stent approaches (9.0 versus 2.1 %; p = 0.002).Conclusion: All-comer patients treated for bifurcated and non-bifurcated target lesions showed similar and low rates of clinical endpoints, suggesting that the DES used are efficacious and safe for treating bifurcated target lesions

    Clinical Outcome Following Stringent Discontinuation of Dual Antiplatelet Therapy After 12 Months in Real-World Patients Treated With Second-Generation Zotarolimus-Eluting Resolute and Everolimus-Eluting Xience V Stents : 2-Year Follow-Up of the Randomized TWENTE Trial

    Get PDF
    Objectives The aim of this study was to assess the safety and efficacy of the implantation of Resolute zotarolimus-eluting stents (ZES) (Medtronic Inc., Santa Rosa, California) and Xience V everolimus-eluting stents (EES) (Abbott Vascular, Santa Clara, California) following strict discontinuation of dual antiplatelet therapy (DAPT) after 12 months. Background Only limited long-term follow-up data are available from head-to-head comparisons of second-generation drug-eluting stents. Methods The randomized TWENTE (The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twente) trial is an investigator-initiated study performed in a population with many complex patients and lesions and only limited exclusion criteria. Patients were randomly assigned 1:1 to ZES (n = 697) or EES (n = 694). Results Two-year follow-up information was available on all patients. The rate of continuation of DAPT beyond 12 months was very low (5.4%). The primary endpoint of target vessel failure, a composite of cardiac death, target vessel–related myocardial infarction, and target vessel revascularization, did not differ between ZES and EES (10.8% vs. 11.6, p = 0.65), despite fewer target lesion revascularizations in patients with EES (2.6% vs. 4.9%, p = 0.03). The patient-oriented composite endpoint was similar (16.4% vs. 17.1%, p = 0.75). Two-year rates of definite or probable stent thrombosis were 1.2% and 1.4%, respectively (p = 0.63). Very late definite or probable stent thrombosis occurred only in 2 patients in each study arm (0.3% vs. 0.3%, p = 1.00). Conclusions After 2 years of follow-up and stringent discontinuation of DAPT beyond 12 months, Resolute ZES and Xience V EES showed similar results in terms of safety and efficacy for treating patients with a majority of complex lesions and off-label indications for drug-eluting stents. (The Real-World Endeavor Resolute Versus Xience V Drug-Eluting Stent Study in Twent

    TCT-47 Two-Year Clinical Outcome of the TWENTE Trial, a Randomized Controlled Trial Comparing Second-Generation Zotarolimus-Eluting Resolute Stents Versus Everolimus-Eluting Xience V Stents in Real-World Patients

    Get PDF
    Background: In the prospective, randomized TWENTE trial, the zotarolimus-eluting Resolute stent was at 1 year follow-up non-inferior to the everolimus-eluting Xience V stent for the primary endpoint target vessel failure. This composite endpoint consisted of cardiac death, clinically indicated target vessel revascularization, or target vessel-related myocardial infarction (MI). So far, few long-term data of prospective head-to-head comparisons between both DES have been reported. Methods: Patients requiring percutaneous coronary interventions (PCI) with DES implantation at Thoraxcentrum Twente in Enschede were randomization between Resolute (Medtronic Vascular, Santa Rosa, CA, USA) and Xience V (Abbott Vascular, Santa Clara, CA, USA) in a 1:1 fashion. Inclusion of all coronary or bypass graft lesions and all clinical settings was permitted except for primary PCI (i.e. acute ST-elevation myocardial infarction (STEMI) was an exclusion criterion). Both external monitoring and clinical event adjudication were performed by an independent external contract research organization (Cardialysis, Rotterdam, the Netherlands). Two year clinical follow-up was performed as indicated in the study protocol. Results: A total of 1,391 patients were enrolled in the TWENTE trial between June 2008 and August 2010. The study population comprised 21.6% diabetics with a vast majority of complex lesions and “off-label” indications for drug-eluting stents (77.4%). Patients presented with either stable angina (48.5%) or unstable angina/Non-STEMI (51.5%). Demographics, baseline angiographic and procedural data, and 2-year clinical follow-up data will be presented. This includes the primary endpoint of the study: Target vessel failure (TVF) at 2 year follow-up. Secondary endpoints include the individual components of the primary endpoint and the incidence of very late stent thrombosis. In addition, results of subgroup analyses will be reported. Conclusions: Results of pre-specified analyses of 2-year clinical outcome of the TWENTE trial will be presented at TCT 2012

    TCT-588 2-Year Clinical Outcome of the Randomized, Multicenter DUTCH PEERS (TWENTE II) Trial, Comparing Cobalt-Chromium Zotarolimus-Eluting Resolute Integrity Stents and Platinum-Chromium Everolimus-Eluting Promus Element Stents in “All-Comer” Patients

    Get PDF
    Background: The multicenter, prospective, randomized, single-blinded, investigator-initiated DUTCH PEERS (TWENTE II) “All Comers” Trial demonstrated at 1-year follow-up the non-inferiority of third-generation Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, CA) versus Promus Element everolimus-eluting stents (Boston Scientific, Natick, MA), based on a similar incidence of the primary endpoint target vessel failure (TVF), a composite of cardiac death, target vessel revascularization (TVR), or myocardial infarction (MI). No other follow-up data beyond 12 months have been published from a randomized head-to-head comparison of both stents. Methods: In 4 study centers in the Netherlands, 1,811 patients were 1:1 randomly assigned to treatment with one of both stents. Patients with any clinical syndrome, any lesion type, and any number of lesions or vessels to be treated were included. Study monitoring and clinical event adjudication were performed by two independent Dutch contract research organizations (Diagram, Zwolle, and Cardialysis, Rotterdam, respectively). Results: DUTCH PEERS examines an all-comer patient population that included 59% of patients with acute coronary syndromes (20% of all patients presented with an acute STEMI) and 66% of patients with complex target lesions. We will compare for both stent groups the 2-year incidence of TVF (primary endpoint) and various secondary endpoints, including individual components of the primary endpoint, the incidence of stent thrombosis, and other composite endpoints, such as target lesion failure, major adverse cardiac events, and the patient-oriented composite endpoint. In addition, we will report the outcome of patients with longitudinal stent deformation after discontinuation of dual anti-platelet therapy. Conclusions: Clinical outcome of the DUTCH PEERS trial at 2-year follow-up will be presented

    Final 5-Year Report of the Randomized BIO-RESORT Trial Comparing 3 Contemporary Drug-Eluting Stents in All-Comers

    Get PDF
    BACKGROUND: In a previous trial, higher 5‐year mortality was observed following treatment with biodegradable polymer Orsiro sirolimus‐eluting stents (SES). We assessed 5‐year safety and efficacy of all‐comers as well as patients with diabetes treated with SES or Synergy everolimus‐eluting stents (EES) versus durable polymer Resolute Integrity zotarolimus‐eluting stents (ZES). METHODS AND RESULTS: The randomized BIO‐RESORT (Comparison of Biodegradable Polymer and Durable Polymer Drug‐Eluting Stents in an All Comers Population) trial enrolled 3514 all‐comer patients at 4 Dutch cardiac centers. Patients aged ≄18 years who required percutaneous coronary intervention were eligible. Participants were stratified for diabetes and randomized to treatment with SES, EES, or ZES (1:1:1). The main end point was target vessel failure (cardiac mortality, target vessel myocardial infarction, or target vessel revascularization). Five‐year follow‐up was available in 3183 of 3514 (90.6%) patients. The main end point target vessel failure occurred in 142 of 1169 (12.7%) patients treated with SES, 130 of 1172 (11.6%) treated with EES, versus 157 of 1173 (14.1%) treated with ZES (hazard ratio [HR], 0.89 [95% CI, 0.71–1.12], P (log‐rank)=0.31; and HR, 0.82 [95% CI, 0.65–1.04], P (log‐rank)=0.10, respectively). Individual components of target vessel failure showed no significant between‐stent difference. Very late definite stent thrombosis rates were low and similar (SES, 1.1%; EES, 0.6%; ZES, 0.9%). In patients with diabetes, target vessel failure did not differ significantly between stent‐groups (SES, 19.8%; EES, 19.2%; versus ZES, 21.1% [P (log‐rank)=0.69 and P (log‐rank)=0.63]). CONCLUSIONS: Orsiro SES, Synergy EES, and Resolute Integrity ZES showed similar 5‐year outcomes of safety and efficacy, including mortality. A prespecified stent comparison in patients with diabetes also revealed no significant differences in 5‐year clinical outcomes. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01674803
    • 

    corecore