6 research outputs found

    Robot kinematic structure classification from time series of visual data

    Full text link
    In this paper we present a novel algorithm to solve the robot kinematic structure identification problem. Given a time series of data, typically obtained processing a set of visual observations, the proposed approach identifies the ordered sequence of links associated to the kinematic chain, the joint type interconnecting each couple of consecutive links, and the input signal influencing the relative motion. Compared to the state of the art, the proposed algorithm has reduced computational costs, and is able to identify also the joints' type sequence

    332 Clinical and prognostic significance of junctional late gadolinium enhancement in patients with non-ischaemic cardiomyopathy

    Get PDF
    Abstract Aims Pulmonary hypertension (PH) carries a poor prognosis in patients with non-ischaemic dilated cardiomyopathy (NIDC). Cardiac magnetic resonance (CMR) with late gadolinium enhancement (LGE) evaluation can identify myocardial abnormalities. In particular, junctional LGE is already an established marker of adverse right ventricular (RV) remodelling in patients with pre-capillary PH. This study sought to assess the prevalence of junctional LGE by CMR in NIDC, its relationship with hemodynamic parameters and, moreover, its prognostic significance. Methods and results Patients with NIDC who underwent right heart catheterization (RHC) and CMR within 3 months in a tertiary hospital were enrolled. Patients with acute heart failure were excluded. Among others, RV and left ventricular (LV) volumes, junctional LGE at CMR, pulmonary artery pressure (PAP) and pulmonary capillary wedge pressure (PCWP) at RHC were tabulated. Pulmonary hypertension was defined accordingly to current Guidelines (median PAP at RHC ≥ 25 mmHg). The primary endpoint consisted of heart failure (HF) hospitalization during follow-up. A total of 188 patients [median age 49 (SD 15), 71% males] were evaluated. At morpho-functional CMR evaluation, most subjects (76%) had important systolic dysfunction (LV EF ≤ 35%). Junctional LGE was observed in 83 (44%) patients. Among patients with junctional LGE, 21 had LGE confined only to the junctional region, while 61 had also mid-wall interventricular septal stria and 21 a mid-wall stria in the lateral free LV wall. Patients with junctional LGE had lower RV EF (49% vs. 56%, P < 0.001) and LV EF (27% vs. 30%, P = 0.012) when compared to those without junctional LGE although no differences in LV and RV dimensions were found. RHC showed PH in 83 patients (44%). Patients with junctional LGE showed a worse hemodynamic profile in terms of PH (55% vs. 36%; P = 0.011) and increase in PCWP (PCWP > 15 mmHg in 60% vs. 42%; P = 0.015) compared to subjects without junctional LGE. Among 79 patients with PH and PCWP > 15 mmHg, 75 (95%) had a combined post capillary and pre-capillary PH (diastolic pressure gradient ≥7 mmHg). Univariate analysis showed that junctional LGE was associated with a worse hemodynamic profile; on multivariable model, RV EF was significantly associated with the presence of junctional LGE (OR: 0.91; 95% CI: 0.87–0.96, P < 0.001). During a median follow-up of 58 months, 33 patients (18%) died or underwent heart transplantation/ventricular assist device implantation, 17% in the junctional LGE group vs. 18% among those without junctional LGE. Thirty-eight patients (20%) had at least one episode of HF, 22 among junctional LGE group and 16 in control group (27% vs. 15%, P = 0.056). When adjusted for age, junctional LGE resulted a significant determinant of HF hospitalization (OR: 2.13, 95% CI: 1.02–4.44, P = 0.044). Conclusions Junctional LGE is detectable in almost half of NIDC patients and it is related to a worse haemodynamic profile, characterized by PH and elevated PCWP. Moreover, after adjustment for age, it was a significant determinant of HF hospitalization during follow-up in our population. Junctional LGE can therefore represent a useful prognostic tool, as marker of adverse ventricular remodelling likely related to ventricular interdependence

    Automatic assessment of the 2-minute walk distance for remote monitoring of people with multiple sclerosis

    Get PDF
    The aim of this study was to investigate the feasibility of automatically assessing the 2-Minute Walk Distance (2MWD) for monitoring people with multiple sclerosis (pwMS). For 154 pwMS, MS-related clinical outcomes as well as the 2MWDs as evaluated by clinicians and derived from accelerometer data were collected from a total of 323 periodic clinical visits. Accelerometer data from a wearable device during 100 home-based 2MWD assessments were also acquired. The error in estimating the 2MWD was validated for walk tests performed at hospital, and then the correlation (r) between clinical outcomes and home-based 2MWD assessments was evaluated. Robust performance in estimating the 2MWD from the wearable device was obtained, yielding an error of less than 10% in about two-thirds of clinical visits. Correlation analysis showed that there is a strong association between the actual and the estimated 2MWD obtained either at hospital (r = 0.71) or at home (r = 0.58). Furthermore, the estimated 2MWD exhibits moderate-to-strong correlation with various MS-related clinical outcomes, including disability and fatigue severity scores. Automatic assessment of the 2MWD in pwMS is feasible with the usage of a consumer-friendly wearable device in clinical and non-clinical settings. Wearable devices can also enhance the assessment of MS-related clinical outcomes

    Automatic Assessment of the 2-Minute Walk Distance for Remote Monitoring of People with Multiple Sclerosis

    Get PDF
    The aim of this study was to investigate the feasibility of automatically assessing the 2-Minute Walk Distance (2MWD) for monitoring people with multiple sclerosis (pwMS). For 154 pwMS, MS-related clinical outcomes as well as the 2MWDs as evaluated by clinicians and derived from accelerometer data were collected from a total of 323 periodic clinical visits. Accelerometer data from a wearable device during 100 home-based 2MWD assessments were also acquired. The error in estimating the 2MWD was validated for walk tests performed at hospital, and then the correlation (r) between clinical outcomes and home-based 2MWD assessments was evaluated. Robust performance in estimating the 2MWD from the wearable device was obtained, yielding an error of less than 10% in about two-thirds of clinical visits. Correlation analysis showed that there is a strong association between the actual and the estimated 2MWD obtained either at hospital (r = 0.71) or at home (r = 0.58). Furthermore, the estimated 2MWD exhibits moderate-to-strong correlation with various MS-related clinical outcomes, including disability and fatigue severity scores. Automatic assessment of the 2MWD in pwMS is feasible with the usage of a consumer-friendly wearable device in clinical and non-clinical settings. Wearable devices can also enhance the assessment of MS-related clinical outcomes

    A wearable device perspective on the standard definitions of disability progression in multiple sclerosis

    No full text
    INTRODUCTION: Multiple sclerosis (MS) is a leading cause of disability among young adults, but standard clinical scales may not accurately detect subtle changes in disability occurring between visits. This study aims to explore whether wearable device data provides more granular and objective measures of disability progression in MS.METHODS: Remote Assessment of Disease and Relapse in Central Nervous System Disorders (RADAR-CNS) is a longitudinal multicenter observational study in which 400 MS patients have been recruited since June 2018 and prospectively followed up for 24 months. Monitoring of patients included standard clinical visits with assessment of disability through use of the Expanded Disability Status Scale (EDSS), 6-minute walking test (6MWT) and timed 25-foot walk (T25FW), as well as remote monitoring through the use of a Fitbit.RESULTS: Among the 306 patients who completed the study (mean age, 45.6 years; females 67%), confirmed disability progression defined by the EDSS was observed in 74 patients, who had approximately 1392 fewer daily steps than patients without disability progression. However, the decrease in the number of steps experienced over time by patients with EDSS progression and stable patients was not significantly different. Similar results were obtained with disability progression defined by the 6MWT and the T25FW.CONCLUSION: The use of continuous activity monitoring holds great promise as a sensitive and ecologically valid measure of disability progression in MS.</p
    corecore