82 research outputs found

    Reply

    Get PDF

    The role of cytochrome c oxidase subunit Va in non-small cell lung carcinoma cells: association with migration, invasion and prediction of distant metastasis

    Get PDF
    BACKGROUND: Lung cancer is one of the most lethal malignancies worldwide, but useful biomarkers of lung cancer are still insufficient. The aim of this study is to identify some membrane-bound protein(s) associated with migration and invasion in human non-small cell lung cancer (NSCLC) cells. METHODS: We classified four NSCLC cell lines into high and low migration/invasion groups by Transwell and Matrigel assays. Using two-dimensional gel electrophoresis and matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS), we identified 10 membrane-associated proteins being significantly overexpressed in the high migration/invasion group. The expression of the target protein in the four NSCLC cell lines was then confirmed by reverse transcription polymerase chain reaction (RT-PCR), western blot and immunostaining. RNA interference technique was applied to observe the influence of the target protein on migration and invasion. Gelatin zymography was also performed to evaluate the activities of matrix metalloproteinase (MMP)-2 and MMP-9. Expression condition of the target protein on surgical specimens was further examined by immunohistochemical staining and the clinicopathologic data were analyzed. RESULTS: We identified a mitochondria-bound protein cytochrome c oxidase subunit Va (COX Va) because of its abundant presence found exclusively in tumorous areas. We also demonstrated that migration and invasion of NSCLC cells decreased substantially after knocking down COX Va by siRNA. Meanwhile, we found a positive correlation between COX Va expression, Bcl-2 expression and activities of MMP-2 and MMP-9 in NSCLC cells. Immunohistochemical staining of surgically resected lung adenocarcinomas in 250 consecutive patients revealed that strong COX Va expression was found in 54.8% (137/250) of patients and correlated positively with the status of lymph node metastasis (P = 0.032). Furthermore, strong COX Va expression was associated with the presence of distant metastasis (P = 0.033). CONCLUSIONS: Our current study showed that COX Va may play a role in migration and invasion of NSCLC cells and can be used as a biomarker to predict aggressiveness of NSCLC

    Biomechanical comparison of lumbar spine instability between laminectomy and bilateral laminotomy for spinal stenosis syndrome – an experimental study in porcine model

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The association of lumbar spine instability between laminectomy and laminotomy has been clinically studied, but the corresponding <it>in vitro </it>biomechanical studies have not been reported. We investigated the hypothesis that the integrity of the posterior complex (spinous process-interspinous ligament-spinous process) plays an important role on the postoperative spinal stability in decompressive surgery.</p> <p>Methods</p> <p>Eight porcine lumbar spine specimens were studied. Each specimen was tested intact and after two decompression procedures. All posterior components were preserved in Group A (Intact). In Group B (Bilateral laminotomy), the inferior margin of L4 lamina and superior margin of L5 lamina were removed, but the L4–L5 supraspinous ligament was preserved. Fenestrations were made on both sides. In Group C (Laminectomy) the lamina and spinous processes of lower L4 and upper L5 were removed. Ligamentum flavum and supraspinous ligament of L4–L5 were removed. A hydraulic testing machine was used to generate an increasing moment up to 8400 N-mm in flexion and extension. Intervertebral displacement at decompressive level L4–L5 was measured by extensometer</p> <p>Results</p> <p>The results indicated that, under extension motion, intervertebral displacement between the specimen in intact form and at two different decompression levels did not significantly differ (<it>P </it>> 0.05). However, under flexion motion, intervertebral displacement of the laminectomy specimens at decompression level L4–L5 was statistically greater than in intact or bilateral laminotomy specimens (<it>P </it>= 0.0000963 and <it>P </it>= 0.000418, respectively). No difference was found between intact and bilateral laminotomy groups. (<it>P </it>> 0.05).</p> <p>Conclusion</p> <p>We concluded that a lumbar spine with posterior complex integrity is less likely to develop segment instability than a lumbar spine with a destroyed anchoring point for supraspinous ligament.</p

    Hypothermic manipulation of bone cement can extend the handling time during vertebroplasty

    Get PDF
    BACKGROUND: Polymethylmethacrylate (PMMA) is commonly used for clinical applications. However, the short handling time increases the probability of a surgeon missing the crucial period in which the cement maintains its ideal viscosity for a successful injection. The aim of this article was to illustrate the effects a reduction in temperature would have on the cement handling time during percutaneous vertebroplasty. METHODS: The injectability of bone cement was assessed using a cement compressor. By twisting the compressor, the piston transmits its axial load to the plunger, which then pumps the bone cement out. The experiments were categorized based on the different types of hypothermic manipulation that were used. In group I (room temperature, sham group), the syringes were kept at 22°C after mixing the bone cement. In group 2 (precooling the bone cement and the container), the PMMA powder and liquid, as well as the beaker, spatula, and syringe, were stored in the refrigerator (4°C) overnight before mixing. In group 3 (ice bath cooling), the syringes were immediately submerged in ice water after mixing the bone cement at room temperature. RESULTS: The average liquid time, paste time, and handling time were 5.1 ± 0.7, 3.4 ± 0.3, and 8.5 ± 0.8 min, respectively, for group 1; 9.4 ± 1.1, 5.8 ± 0.5, and 15.2 ± 1.2 min, respectively, for group 2; and 83.8 ± 5.2, 28.8 ± 6.9, and 112.5 ± 11.3 min, respectively, for group 3. The liquid and paste times could be increased through different cooling methods. In addition, the liquid time (i.e. waiting time) for ice bath cooling was longer than for that of the precooling method (p < 0.05). CONCLUSIONS: Both precooling (i.e. lowering the initial temperature) and ice bath cooling (i.e. lowering the surrounding temperature) can effectively slow polymerization. Precooling is easy for clinical applications, while ice bath cooling might be more suitable for multiple-level vertebroplasty. Clinicians can take advantage of the improved injectability without any increased cost

    Pullout strength of pedicle screws with cement augmentation in severe osteoporosis: A comparative study between cannulated screws with cement injection and solid screws with cement pre-filling

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Pedicle screws with PMMA cement augmentation have been shown to significantly improve the fixation strength in a severely osteoporotic spine. However, the efficacy of screw fixation for different cement augmentation techniques, namely solid screws with retrograde cement pre-filling versus cannulated screws with cement injection through perforation, remains unknown. This study aimed to determine the difference in pullout strength between conical and cylindrical screws based on the aforementioned cement augmentation techniques. The potential loss of fixation upon partial screw removal after screw insertion was also examined.</p> <p>Method</p> <p>The Taguchi method with an L<sub>8 </sub>array was employed to determine the significance of design factors. Conical and cylindrical pedicle screws with solid or cannulated designs were installed using two different screw augmentation techniques: solid screws with retrograde cement pre-filling and cannulated screws with cement injection through perforation. Uniform synthetic bones (test block) simulating severe osteoporosis were used to provide a platform for each screw design and cement augmentation technique. Pedicle screws at full insertion and after a 360-degree back-out from full insertion were then tested for axial pullout failure using a mechanical testing machine.</p> <p>Results</p> <p>The results revealed the following 1) Regardless of the screw outer geometry (conical or cylindrical), solid screws with retrograde cement pre-filling exhibited significantly higher pullout strength than did cannulated screws with cement injection through perforation (<it>p </it>= 0.0129 for conical screws; <it>p </it>= 0.005 for cylindrical screws). 2) For a given cement augmentation technique (screws without cement augmentation, cannulated screws with cement injection or solid screws with cement pre-filling), no significant difference in pullout strength was found between conical and cylindrical screws (<it>p ></it>0.05). 3) Cement infiltration into the open cell of the test block led to the formation of a cement/bone composite structure. Observations of the failed specimens indicated that failure occurred at the composite/bone interface, whereas the composite remained well bonded to the screws. This result implies that the screw/composite interfacial strength was much higher than the composite/bone interfacial strength. 4) The back-out of the screw by 360 degrees from full insertion did not decrease the pullout strength in any of the studied cases. 5) Generally, larger standard deviations were found for the screw back-out cases, implying that the results of full insertion cases are more repeatable than those of the back-out cases.</p> <p>Conclusions</p> <p>Solid screws with retrograde cement pre-filling offer improved initial fixation strength when compared to that of cannulated screws with cement injection through perforation for both the conically and cylindrically shaped screw. Our results also suggest that the fixation screws can be backed out by 360 degrees for intra-operative adjustment without the loss of fixation strength.</p

    Epidemiological survey of orthopedic joint dislocations based on nationwide insurance data in Taiwan, 2000-2005

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The epidemiology of acute orthopedic dislocations is poorly understood. A nationwide database provides a valuable resource for examining this issue in the Taiwanese population.</p> <p>Methods</p> <p>A 6-year retrospective cohort study of 1,000,000 randomly-sampled beneficiaries from the year 2005 was used as the original population. Based on the hospitalized and ambulatory data, the concomitant ICD9-CM diagnosis codes and treatment codes were evaluated and classified into 8 and 3 major categories, respectively. The cases matching both inclusive criteria of dislocation-related diagnosis codes and treatment codes were defined as incident cases.</p> <p>Results</p> <p>During 2000-2005, the estimated annual incidence (per 100,000 population) of total orthopedic dislocations in Taiwan was 42.1 (95%CI: 38.1-46.1). The major cause of these orthopedic dislocations was traffic accidents (57.4%), followed by accident falls (27.5%). The annual incidence dislocation by location was shoulder, 15.3; elbow, 7.7; wrist, 3.5; finger, 4.6; hip, 5.2; knee, 1.4; ankle, 2.0; and foot, 2.4. Approximately 16% of shoulder dislocations occurred with other concomitant fractures, compared with 17%, 53%, 16%, 76% and 52%, respectively, of dislocated elbow, wrist, hip, knee, and ankle cases. Including both simple and complex dislocated cases, the mean medical cost was US612fortreatmentofashoulderdislocation,612 for treatment of a shoulder dislocation, 504 for the elbow, 1,232forthewrist,1,232 for the wrist, 1,103 for the hip, 1,888fortheknee,and1,888 for the knee, and 1,248 for the ankle.</p> <p>Conclusions</p> <p>In Taiwan, three-quarters of all orthopedic dislocations were of the upper limbs. The most common complex fracture-dislocation was of the knee, followed by the wrist and the ankle. Those usually needed a treatment combined with open reduction of fractures and resulted in a higher direct medical expenditure.</p

    Cement leakage causes potential thermal injury in vertebroplasty

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Percutaneous vertebroplasty by injecting PMMA bone cement into the fractured vertebrae has been widely accepted in treatment of spinal compression fracture. However, the exothermic polymerization of bone cement may cause osseous or neural tissue injury. This study is thus designed to evaluate the potential risk of thermal damage in percutaneous vertebroplasty.</p> <p>Method</p> <p>Twelve porcine vertebrae were immersed in 37°C saline for the experiment. In the first stage of the study, vertebroplasty without cement leakage (control group, n = 6) was simulated. The anterior cortex, foramen, posterior cortex and the center of the vertebral body were selected for temperature measurement. Parameters including peak temperature and duration above 45°C were recorded. In the second stage, a model (n = 6) simulating bone cement leaking into the spinal canal was designed. The methods for temperature measurement were identical to those used in the first stage.</p> <p>Results</p> <p>In Stage 1 of the study (vertebroplasty of the porcine vertebral body in the absence of cement leakage), the average maximal temperature at the anterior cortex was 42.4 ± 2.2°C; at the neural foramen 39.5 ± 2.1°C; at the posterior cortex 40.0 ± 2.5°C and at the vertebral center, 68.1 ± 3.4°C. The average time interval above 45°C was 0 seconds at the anterior cortex; at the neural foramen, 0 seconds; at the posterior cortex, 0 seconds and at the vertebral center, 223 seconds. Thus, except at the core of the bone cement, temperatures around the vertebral body did not exceed 45°C. In Stage 2 of the study (cement leakage model), the average maximal temperature at the anterior cortex was 42.7 ± 2.4°C; at the neural foramen, 41.1 ± 0.4°C; at the posterior cortex, 59.1 ± 7.6°C and at the vertebral center, 77.3 ± 5.7°C. The average time interval above 45°C at the anterior cortex was 0 seconds; at the neural foramen, 0 seconds; at the posterior cortex, 329.3 seconds and at the vertebral center, 393.2 seconds. Based on these results, temperatures exceeded 45°C at the posterior cortex and at the vertebral center.</p> <p>Conclusions</p> <p>The results indicated that, for bone cement confined within the vertebra, curing temperatures do not directly cause thermal injury to the nearby soft tissue. If bone cement leaks into the spinal canal, the exothermic reaction at the posterior cortex might result in thermal injury to the neural tissue.</p

    Multidisciplinary Taiwan consensus for the use of conventional TACE in hepatocellular carcinoma treatment

    Get PDF
    Developed in early 1980s, transarterial chemoembolization (TACE) with Lipiodol was adopted globally after large-scale randomized control trials and meta-analyses proving its effectiveness were completed. Also known as “conventional TACE” (cTACE), TACE is currently the first-line treatment for patients with unresectable intermediate stage hepatocellular carcinoma (HCC) and delivers both ischemic and cytotoxic effects to targeted tumors. Although new technology and clinical studies have contributed to a more comprehensive understanding of when and how to apply this widely-adopted therapeutic modality, some of these new findings and techniques have yet to be incorporated into a guideline appropriate for Taiwan. In addition, differences in the underlying liver pathologies and treatment practices for transcatheter embolization between Taiwan and other Asian or Western populations have not been adequately addressed, with significant variations in the cTACE protocols adopted in different parts of the world. These mainly revolve around the amount and type of chemotherapeutic agents used, the type of embolic materials, reliance on Lipiodol, and the degree of selectiveness in catheter positioning. Subsequently, interpreting and comparing results obtained from different centers in a systematic fashion remain difficult, even for experienced practitioners. To address these concerns, we convened a panel of experts specializing in different aspects of HCC treatment to devise modernized recommendations that reflect recent clinical experiences, as well as cTACE protocols which are tailored for use in Taiwan. The conclusions of this expert panel are described herein
    corecore