27,639 research outputs found

    Fabrication of large tungsten structures by chemical vapor deposition

    Get PDF
    Process is accomplished by reducing tungsten hexafluoride with hydrogen. Metallic tungsten of essentially 100 percent purity and density is produced and built up as dense deposit on heated mandrel assembly. Process variations are building up, sealing or bonding refractory metals at temperatures below transition temperatures of base metal substrates

    Remotely sensed and laboratory spectral signatures of an ocean-dumped acid waste

    Get PDF
    An ocean-dumped acid waste plume was studied by using a rapid scanning spectrometer to remotely measure ocean radiance from a helicopter. The results of these studies are presented and compared with results from sea truth samples and laboratory experiments. An ocean spectral reflectance signature and a laboratory spectral transmission signature were established for the iron-acid waste pollutant. The spectrally and chemically significant component of the acid waste pollutant was determined to be ferric iron

    Simultaneous muscle force and displacement transducer

    Get PDF
    A myocardial transducer for simultaneously measuring force and displacement within a very small area of myocardium is disclosed. The transducer comprised of an elongated body forked at one end to form an inverted Y shaped beam with each branch of the beam constituting a low compliant tine for penetrating the myocardium to a predetermined depth. Bonded to one of the low compliance tines is a small piezoresistive element for converting a force acting on the beam into an electrical signal. A third high compliant tine of the transducer, which measures displacement of the myocardium in a direction in line with the two low compliant tines, is of a length that just pierces the surface membrane. A small piezoresistive element is bonded to the third tine at its upper end where its bending is greatest. Displacement of the myocardium causes a deformation in curvature of the third tine, and the second small piezoresistive element bonded to the surface of its curved end converts its deformation into an electrical signal

    Multifunctional transducer

    Get PDF
    Several parameters of a small region of a muscle tissue or other object, can be simultaneously measured using with minimal traumatizing or damage of the object, a trifunctional transducer which can determine the force applied by a muscle fiber, the displacement of the fiber, and the change in thickness of the fiber. The transducer has three legs with inner ends joined together and outer ends formed to piece the tissue and remain within it. Two of the legs are relatively stiff, to measure force applied by the tissue, and a third leg is relatively flexible to measure displacement of the tissue relative to one or both stiff legs, and with the three legs lying in a common plane so that the force and displacement measurements all relate to the same direction of muscle movements. A flexible loop is attached to one of the stiff legs to measure changes in muscle thickness, with the upper end of the loop fixed to the leg and the lower end of the loop bearing against the surface of the tissue and being free to slide on the leg

    Myocardium wall thickness transducer and measuring method

    Get PDF
    A miniature transducer for measuring changes of thickness of the myocardium is described. The device is easily implantable without traumatizing the subject, without affecting the normal muscle behavior, and is removable and implantable at a different muscle location. Operating features of the device are described

    Catheter tip force transducer for cardiovascular research

    Get PDF
    A force transducer for measuring dynamic force activity within the heart of a subject essentially consists of a U-shaped beam of low elastic compliance material. Two lines extend from the beams's legs and a long coil spring is attached to the beam. A strain gauge is coupled to one of the beam's legs to sense deflections thereof. The beam with the tines and most of the spring are surrounded by a flexible tube, defining a catheter, which is insertable into a subject's heart through an appropriate artery. The tines are extractable from the catheter for implantation into the myocardium by pushing on the end of the spring which extends beyond the external end of the catheter

    Evaluation of remote sensing in control of pink bollworm in cotton

    Get PDF
    The author has identified the following significant results. This project is to identify and map cotton fields in the southern deserts of California. Cotton in the Imperial, Coachella, and Palo Verde Valleys is heavily infested by the pink bollworm which affects both the quantity and quality of cotton produced. In California the growing season of cotton is regulated by establishing planting and plowdown dates. These procedures ensure that the larvae, whose diapause or resting period occurs during the winter months, will have no plant material on which to feed, thus inhibiting spring moth emergence. the underflight data from the U-2 aircraft has shound that it is possible to detect the differences between a growing, a defoliated, and plowed down field providing the locations of the fields are known. The ERTS-1 MSS data are being analyzed using an I2S optical color combiner to determine which combinations of dates and colors will identify cotton fields and thus provide the data needed to produce maps of the fields for the forthcoming season

    Evaluation of remote sensing in control of pink bollworm in cotton

    Get PDF
    The author has identified the following significant results. This investigation is to evaluate the use of a satellite in monitoring the cotton production regulation program of the State of California as an aid in controlling pink bollworm infestation in the southern deserts of California. Color combined images of ERTS-1 multispectral images simulating color infrared are being used for crop identification. The status of each field (crop, bare, harvested, wet, plowed) is mapped from the imagery and is then compared to ground survey information taken at the time of ERTS-1 overflights. A computer analysis has been performed to compare field and satellite data to a crop calendar. Correlation to date has been 97% for field condition. Actual crop identification varies; cotton identification is only 63% due to lack of full season coverage

    Chronology of the Development of the David Dudley Field Code

    Get PDF

    Chronology of the Development of the David Dudley Field Code

    Get PDF
    corecore