17 research outputs found

    An MRS- and PET-guided biopsy tool for intraoperative neuronavigational systems

    Get PDF
    OBJECTIVEGlioma heterogeneity and the limitations of conventional structural MRI for identifying aggressive tumor components can limit the reliability of stereotactic biopsy and, hence, tumor characterization, which is a hurdle for developing and selecting effective treatment strategies. In vivo MR spectroscopy (MRS) and PET enable noninvasive imaging of cellular metabolism relevant to proliferation and can detect regions of more highly active tumor. Here, the authors integrated presurgical PET and MRS with intraoperative neuronavigation to guide surgical biopsy and tumor sampling of brain gliomas with the aim of improving intraoperative tumor-tissue characterization and imaging biomarker validation.METHODSA novel intraoperative neuronavigation tool was developed as part of a study that aimed to sample high-choline tumor components identified by multivoxel MRS and 18F-methylcholine PET-CT. Spatially coregistered PET and MRS data were integrated into structural data sets and loaded onto an intraoperative neuronavigation system. High and low choline uptake/metabolite regions were represented as color-coded hollow spheres for targeted stereotactic biopsy and tumor sampling.RESULTSThe neurosurgeons found the 3D spherical targets readily identifiable on the interactive neuronavigation system. In one case, areas of high mitotic activity were identified on the basis of high 18F-methylcholine uptake and elevated choline ratios found with MRS in an otherwise low-grade tumor, which revealed the possible use of this technique for tumor characterization.CONCLUSIONSThese PET and MRI data can be combined and represented usefully for the surgeon in neuronavigation systems. This method enables neurosurgeons to sample tumor regions based on physiological and molecular imaging markers. The technique was applied for characterizing choline metabolism using MRS and 18F PET; however, this approach provides proof of principle for using different radionuclide tracers and other MRI methods, such as MR perfusion and diffusion.</jats:sec

    A randomised comparison evaluating changes in bone mineral density in advanced prostate cancer: luteinising hormone-releasing hormone agonists versus transdermal oestradiol

    Get PDF
    Background Luteinising hormone-releasing hormone agonists (LHRHa), used as androgen deprivation therapy (ADT) in prostate cancer (PCa) management, reduce serum oestradiol as well as testosterone, causing bone mineral density (BMD) loss. Transdermal oestradiol is a potential alternative to LHRHa. Objective To compare BMD change in men receiving either LHRHa or oestradiol patches (OP). Design, setting, and participants Men with locally advanced or metastatic PCa participating in the randomised UK Prostate Adenocarcinoma TransCutaneous Hormones (PATCH) trial (allocation ratio of 1:2 for LHRHa:OP, 2006–2011; 1:1, thereafter) were recruited into a BMD study (2006–2012). Dual-energy x-ray absorptiometry scans were performed at baseline, 1 yr, and 2 yr. Interventions LHRHa as per local practice, OP (FemSeven 100 μg/24 h patches). Outcome measurements and statistical analysis The primary outcome was 1-yr change in lumbar spine (LS) BMD from baseline compared between randomised arms using analysis of covariance. Results and limitations A total of 74 eligible men (LHRHa 28, OP 46) participated from seven centres. Baseline clinical characteristics and 3-mo castration rates (testosterone ≤1.7 nmol/l, LHRHa 96% [26 of 27], OP 96% [43 of 45]) were similar between arms. Mean 1-yr change in LS BMD was −0.021 g/cm3 for patients randomised to the LHRHa arm (mean percentage change −1.4%) and +0.069 g/cm3 for the OP arm (+6.0%; p < 0.001). Similar patterns were seen in hip and total body measurements. The largest difference between arms was at 2 yr for those remaining on allocated treatment only: LS BMD mean percentage change LHRHa −3.0% and OP +7.9% (p < 0.001). Conclusions Transdermal oestradiol as a single agent produces castration levels of testosterone while mitigating BMD loss. These early data provide further supporting evidence for the ongoing phase 3 trial

    Disconnection between the default mode network and medial temporal lobes in post-traumatic amnesia

    Get PDF
    Post-traumatic amnesia is very common immediately after traumatic brain injury. It is characterised by a confused, agitated state and a pronounced inability to encode new memories and sustain attention. Clinically, post-traumatic amnesia is an important predictor of functional outcome. However, despite its prevalence and functional importance, the pathophysiology of post-traumatic amnesia is not understood. Memory processing relies on limbic structures such as the hippocampus, parahippocampus and parts of the cingulate cortex. These structures are connected within an intrinsic connectivity network, the Default Mode Network. Interactions within the Default Mode Network can be assessed using resting state functional magnetic resonance imaging, which can be acquired in confused patients unable to perform tasks in the scanner. Here we used this approach to test the hypothesis that the mnemonic symptoms of post-traumatic amnesia are caused by functional disconnection within the Default Mode Network. We assessed whether the hippocampus and parahippocampus showed evidence of transient disconnection from cortical brain regions involved in memory processing. 19 traumatic brain injury patients were classified into post-traumatic amnesia and traumatic brain injury control groups, based on their performance on a paired associates learning task. Cognitive function was also assessed with a detailed neuropsychological test battery. Functional interactions between brain regions were investigated using resting-state functional magnetic resonance imaging. Together with impairments in associative memory patients in post-traumatic amnesia demonstrated impairments in information processing speed and spatial working memory. Patients in post-traumatic amnesia showed abnormal functional connectivity between the parahippocampal gyrus and posterior cingulate cortex. The strength of this functional connection correlated with both associative memory and information processing speed and normalised when these functions improved. We have previously shown abnormally high posterior cingulate cortex connectivity in the chronic phase after traumatic brain injury, and this abnormality was also observed in patients with post-traumatic amnesia. Patients in post-traumatic amnesia showed evidence of widespread traumatic axonal injury measured using diffusion magnetic resonance imaging. This change was more marked within the cingulum bundle, the tract connecting the parahippocampal gyrus to the posterior cingulate cortex. These findings provide novel insights into the pathophysiology of post-traumatic amnesia and evidence that memory impairment acutely after traumatic brain injury results from altered parahippocampal functional connectivity, perhaps secondary to the effects of axonal injury on white matter tracts connecting limbic structures involved in memory processing

    Imaging and Tissue Biomarkers of Choline Metabolism in Diffuse Adult Glioma: 18F-Fluoromethylcholine PET/CT, Magnetic Resonance Spectroscopy, and Choline Kinase α

    Get PDF
    The cellular and molecular basis of choline uptake on PET imaging and MRS-visible choline containing compounds is not well understood. Choline kinase alpha (ChoKa) is an enzyme that phosphorylates choline, an essential step in membrane synthesis. We investigate choline metabolism through 18F-fluoromethylcholine (18F-FMC) PET, MRS and tissue ChoKa in human glioma. 14 patients with suspected diffuse glioma underwent multimodal 3T MRI and dynamic 18F FMC PET/CT prior to surgery. Co-registered PET and MRI data were used to target biopsies to regions of high and low choline signal, and immunohistochemistry for ChoKa expression was performed. 18F-FMC/PET differentiated WHO grade IV from grade II and III tumours, whereas MRS differentiated grade III/IV from grade II tumours. Tumoural 18F-FMC/PET uptake was higher than in normal-appearing white matter across all grades and markedly elevated within regions of contrast enhancement. 18F-FMC/PET correlated weakly with MRS Cho ratios. ChoKa expression on IHC was negative or weak in all but one GBM sample, and did not correlate with tumour grade or imaging choline markers. MRS and 18F-FMC/PET provide complimentary information on glioma choline metabolism. Tracer uptake is, however, potentially confounded by blood-brain barrier permeability. ChoKa overexpression does not appear to be a common feature in diffuse glioma

    Reliability of dynamic contrast-enhanced magnetic resonance imaging data in primary brain tumours: a comparison of Tofts and shutter speed models

    Get PDF
    Purpose To investigate the robustness of pharmacokinetic modelling of DCE-MRI brain tumour data and to ascertain reliable perfusion parameters through a model selection process and a stability test. Methods DCE-MRI data of 14 patients with primary brain tumours were analysed using the Tofts model (TM), the extended Tofts model (ETM), the shutter speed model (SSM) and the extended shutter speed model (ESSM). A no-effect model (NEM) was implemented to assess overfitting of data by the other models. For each lesion, the Akaike Information Criteria (AIC) was used to build a 3D model selection map. The variability of each pharmacokinetic parameter extracted from this map was assessed with a noise propagation procedure, resulting in voxel-wise distributions of the coefficient of variation (CV). Results The model selection map over all patients showed NEM had the best fit in 35.5% of voxels, followed by ETM (32%), TM (28.2%), SSM (4.3%) and ESSM (<0.1%). In analysing the reliability of Ktrans, when considering regions with a CV<20%, ≈25% of voxels were found to be stable across all patients. The remaining 75% of voxels were considered unreliable. Conclusions The majority of studies quantifying DCE-MRI data in brain tumours only consider a single model and whole-tumour statistics for the output parameters. Appropriate model selection, considering tissue biology and its effects on blood brain barrier permeability and exchange conditions, together with an analysis on the reliability and stability of the calculated parameters, is critical in processing robust brain tumour DCE-MRI data

    Computer-assisted detection software for CT colonography: effect of sphericity filter on performance characteristics for patients with and without fecal tagging

    No full text
    The aim of this study is to investigate the effect of changing sphericity filter values on performance of a computer assisted detection (CAD) system for CT colonography for data with and without fecal tagging. Colonography data from 138 patients with 317 validated polyps were divided into those with (86) and without (52) fecal tagging. Polyp coordinates were established by three observers and datasets analysed subsequently by a proprietary CAD system used at four discrete sphericity filter settings. Prompts were compared with the known coordinates in order to determine sensitivity and specificity. Sensitivity was highest at low sphericity; of 164 polyps 6 mm or more, 144 (87.8%) were detected at sphericity 0.3, and 132 (80.1%) at sphericity 0.9. Of 42 polyps measuring 10 mm or more, 40 (95.2%) were detected at sphericity 0.3, and 36 (85.7%) at sphericity 0.9. There was no significant difference in sensitivity for tagged and un-tagged data but specificity was reduced in tagged data at low sphericity and significantly reduced in untagged data at high sphericity. CAD had a sensitivity of 95.2% for polyps measuring 1 cm or more and 87.8% for polyps 6 mm or more when used at a sphericity setting of 0.3. Higher sphericity settings increased specificity while reducing sensitivity. The bowel preparation used significantly impacts on specificity

    CT Colonography: Automated Measurement of Colonic Polyps Compared with Manual Techniques—Human in Vitro Study

    No full text
    PURPOSE: To prospectively investigate the relative accuracy and reproducibility of manual and automated computer software measurements by using polyps of known size in a human colectomy specimen. MATERIALS AND METHODS: Institutional review board approval was obtained for the study; written consent for use of the surgical specimen was obtained. A colectomy specimen containing 27 polyps from a 16-year-old male patient with familial adenomatous polyposis was insufflated, submerged in a container with solution, and scanned at four-section multi-detector row computed tomography (CT). A histopathologist measured the maximum dimension of all polyps in the opened specimen. Digital photographs and line drawings were produced to aid CT-histologic measurement correlation. A novice (radiographic technician) and an experienced (radiologist) observer independently estimated polyp diameter with three methods: manual two-dimensional (2D) and manual three-dimensional (3D) measurement with software calipers and automated measurement with software (automatic). Data were analyzed with paired t tests and Bland-Altman limits of agreement. RESULTS: Seven polyps (<or=6-mm diameter) could not be extracted by using the software; 20 polyps (5-15-mm diameter) remained for analysis. Automated measurement was not significantly different from histologic size for the experienced reader (mean difference, 0.63 mm; P=.06) or novice reader (mean difference, 0.58 mm; P=.12). With manual 2D measurement and manual 3D measurement, the experienced reader (1.21-mm mean difference, P<.001, and 0.68-mm mean difference, P=.03, respectively) and novice reader (1.54-mm mean difference, P<.001, and 0.84-mm mean difference, P=.002, respectively) significantly underestimated polyp size. Interobserver agreement was good and similar for all three methods (95% limits of agreement span, approximately 2.5 mm). Intraobserver agreement was related to reader experience, with differences of up to 2.5 mm within expected limits of agreement. CONCLUSION: For polyps smaller than 1 cm, measurement differences of up to 2.5 mm are within the expected limits of inter- and intraobserver agreement for all measurement techniques. Automated and manual 3D polyp measurements are more accurate than manual 2D measurements

    Comparison of the Tofts and the Shutter Speed Model for DCE-MRI in patients with Brain Glioma

    No full text
    Gliomas are the most common primary brain tumour and there is a wide interest in imaging techniques that stratify tumour behaviour and therapeutic response. PET scans performed with choline based radiotracers are being studied as imaging markers of cell proliferation as choline is a key component of cell membranes. The basis for choline-PET is that primary brain tumours show increased levels of choline uptake when tumour cells are rapidly dividing . In this study, we compared the results of the quantification of both DCE-MRI and dynamic 18F-fluoromethylcholine (FMC) PET on 14 patients with primary untreated glioma. In particular, we applied the Tofts model (TM) and the shutter-speed model (SSM) to DCE-MRI data and spectral analysis (SA) to dynamic FMC-PET data
    corecore