    Extended depth of focus intraocular lens: Chromatic performance

    Get PDF
    We describe a first-and-second-diffractive-order intraocular lens ((1st,2nd)DIOL) within the class of hybrid refractive-diffractive designs for intraocular lenses (IOLs) and analyse its properties of focus extension and compensation of longitudinal chromatic aberration (LCA), particularly for lenses with low addition. Power, energy efficiency and their wavelength dependence are extended from monofocal IOL and conventional bifocal zeroth-and-first-diffractive-order IOL ((0th,1st)DIOL) to (1st,2nd)DIOL of low addition. Compensation of LCA is experimentally assessed in optical bench through the through-focus energy efficiency of three Tecnis IOLs with red, green and blue illuminations: ZA9003 (monofocal), ZKB00 (bifocal (0th,1st)DIOL with + 2.75 D add) and Symfony ZXR00. We prove Tecnis Symfony ZXR00 IOL can be considered an example of (1st,2nd)DIOL design of low addition, with LCA compensation in both the distance and intermediate foci, whereas the bifocal (0th,1st)DIOL does not compensate in the distance focus. However, the energy efficiency of (1st,2nd)DIOL for wavelengths other than the design wavelength is markedly more asymmetric.Postprint (published version

    Clinical assessment of chromatic aberration in phakic and pseudophakic eyes using a simple autorefractor

    Get PDF
    We describe a psychophysical method and a simple setup – an autorefractor with a Scheiner disc, sequentially illuminated with red and blue lights – for the clinical assessment of the longitudinal chromatic aberration (LCA) in phakic and pseudophakic patients. This method applies to the unaccommodated eye, even in the presence of positive or negative refractive errors and astigmatism. It measures the chromatic difference of refraction as an estimate of LCA. We built a proof of concept from inexpensive and off-the-shelf optomechanical components with which we obtained the preliminary clinical results presented in the paper. We considered one control group of phakic patients and three groups of pseudophakic patients with monofocal implants of different designs and materials. The results, satisfactory and consistent with those reported by other researchers in related works, demonstrate the method and system feasibility.Peer ReviewedPostprint (published version

    Patient-Perceived and Laboratory-Measured Halos Associated with Diffractive Bifocal and Trifocal Intraocular Lenses

    Get PDF
    Purpose: To examine and assess the halos generated in distance vision by multifocal intraocular lenses (IOLs) using both in vitro objective and in vivo subjective methods. Setting: The objective method was carried out in the optics laboratory of the Applied Optics and Image Processing Group (Universitat Politècnica de Catalunya -Barcelona). The psychophysical and subjective methods were carried out in the Instituto de Oftalmología Avanzada Madrid Innova Ocular. Design: Optical bench results and prospective evaluation of consecutive cases. Methods: The IOLs examined were TECNIS®one-piece bifocals with addition powers of +4.00 D, +3.25 D, and +2.75 D and the trifocals AT-LISA-tri® and FineVision®. In the objective assessment, we examined halos around the far focus images of a pinhole formed by each IOL in an optical bench. For the in vivo study, we recruited 100 patients who had been bilaterally implanted one month earlier with the IOLs under study. Participants were subjected to psychophysical halometry (Halo v1.0) on the eye with better, distance-corrected, visual acuity and were required to subjectively grade halos by responding to the question “How much do halos bother you?” Results: The objective method revealed that the halo size increased with addition power and that the two trifocals gave rise to a double-halo pattern. Scores in the halometry also indicated a direct relationship between the halo size and addition power. The subjective results indicated fewer complaints about halos associated with the trifocal than bifocal IOLs. Conclusions: The addition power of the tested IOLs affected both laboratory-measured and patient-perceived halos. Trifocal lenses generated fewer complaints about halos. Precise: Multifocal intraocular lenses (MIOLs) give rise to halos observed by patients under conditions of dim lighting. This study compares laboratory characterized halos generated by five MIOLs with patient-perceived halos.Postprint (author's final draft

    Spatio-chromatic vision with multifocal diffractive intraocular lens

    Get PDF
    Background This study aims to detect alterations in the spatio-chromatic pseudophakic vision produced by multifocal diffractive intraocular lenses (IOLs) and provides a physical interpretation. Methods In vitro characterization of the imaging performance of two diffractive IOLs: AT LISA Tri (Zeiss) and FineVision (PhysIOL) in on-bench model eye illuminated with red (R, 625 nm), green (G, 530 nm) and blue (B, 455 nm) lights. We used the metrics: energy efficiency (EE), area under the modulation transfer function, longitudinal chromatic aberration (LCA), and halo intensity. Through-focus (TF) analysis and calculation of the expected defocus curve under white (W) daylight were included. In vivo visual acuity (VA) of 50 pseudophakics (60 eyes) was assessed under W, R, G, B lights at far and near. Two clinical experiments evaluated LCA and R, G, B TF-EE effects on pseudophakic vision and their relative importance. Results Clinical mean VA values under W light agreed with the predicted values at far and near for both IOLs. LCA measurements and R, G, B TF-EE curves were consistent with their lens design based on the 0th and 1st diffraction orders operative for far and near vision, respectively. LCA effects were compensated at near but noticed at far (-¿0.75 D under B light). We detected strong asymmetry in visual resolution depending on the object distance and the illuminating wavelength—red predominance at far, blue predominance at near—in consistency with the TF-EE measurements. Conclusions Diffractive multifocal IOL designs produce asymmetries in the spatio-chromatic vision of pseudophakics beyond the alterations strictly due to LCA. VA asymmetry for far/near object distance under R and B illumination is clinically detectable in subjects implanted with IOLs with 0th and 1st diffraction orders for far and near vision, respectively. Such VA asymmetry cannot be explained solely from the influence of defocus, as would be derived from a chromatic difference of power, but mainly from the wavelength dependence of the EE.Agencia Estatal de Investigación from Spanish Government (Grant No. PID2020-114582RB-I00/AEI/10. 13039/501100011033).Peer ReviewedPostprint (published version

    Impact of lens material on objective refraction in eyes with trifocal diffractive intraocular lenses

    Get PDF
    Purpose: Compare subjective (Rx) and objective (ObjRx) refractions outcomes with two autorefractors models and an aberrometer in eyes implanted with a hydrophobic trifocal IOL (FineVision POD F GF, Physiol, Liége, Belgium) and a hydrophilic one (FineVision POD F, Physiol, Liége, Belgium). Methods: Prospective comparative cohort study, with 100 subjects randomly assigned to either the POD F group (n = 50) or the POD F-GF group (n = 50). Postoperative eye examinations at 1-month visit included seven result sets, one for each assessment method: Rx, AR (automated refraction measured with the autorefractor KR8800), WF-P (Zernike-coefficients-based objective refraction, photopic pupil size), WF-M (Zernike-coefficients-based objective refraction, mesopic pupil size), WF-4 (Zernike-coefficients-based objective refraction, 4 mm pupil), OPD-C (automated refraction measured with the aberrometer OPD in the central pupil/photopic conditions), and OPD-M (automated refraction measured with the aberrometer OPD under mesopic conditions). Results: Mean differences between ObjRx and Rx reached statistical significance for sphere and spherical equivalent (M) only with OPD-C in the POD F-GF group. All ObjRx methods showed significant differences with Rx in the POD F group, with some values differing by more than 0.50 D (-0.58 D in M for the WF-P). Bland Altman plots showed better agreement for the astigmatic components, and for sphere and spherical equivalents in both IOL groups measured with AR and OPD-M. Conclusions: None of the objective methods of refraction evaluated in this study were as reliable as the subjective refraction, irrespective of the lens material, but POD F-GF ObjRx seems to differ less with Rx than POD F ObjRx values.Award-winningPostprint (author's final draft

    Pupil size differences between female and male patients after cataract surgery

    Get PDF
    Purpose To evaluate the changes in pupil diameter in women and men after cataract surgery. The correlation of pupillary changes with the variables age and anterior chamber depth will be analyzed. Methods The values of 109 randomized eyes who underwent cataract surgery were obtained and divided into two groups, 71 women and 38 men. Pupil diameter was measured preoperatively and 3-months postoperatively using the pupillometer software of the Topolyzer Vario (Wavelight Laser Technologie AG). Anterior chamber depth was obtained with Pentacam® (Oculus). Differences in pupillary diameters were investigated and correlations with age and anterior chamber depth were analyzed. Results For mesopic pupils, the male group had greater reduction in their postoperative pupillary diameter, -0.56 mm (-12.4%), than the female group, -0.38 mm (-8.2%), P = 0.025. Photopic postoperative pupils reduced to a lesser extent, yet more in men than in women (-0.11mm [-4.5%] vs. -0.04 [-1.6%], P = 0.048). Weak significant negative correlation was found between photopic pupillary changes in women with age (r = -0.24, P = 0.041), and positive correlation for mesopic pupillary changes in men with age (r = +0.34, P = 0.039). Conclusions Patients experience pupil reduction after cataract surgery in general, but more in men than in women and for both photopic and mesopic lighting conditions. The differences are statistically significant and have moderate clinical relevance. Concerning pupillary changes, weak but opposite sign correlations were found between male/female gender and age.This work was supported by the Spanish Ministerio de Economía y Competitividad and FEDERfunds under project Ref. DPI2016-76019-RPeer ReviewedPostprint (author's final draft
    • …