    Assessing the benefits and risks of application of inverter drives in industry

    Get PDF
    This paper presents the impact assessment of converters installed in an industrial plant on the power quality in internal power grid of the plant. The analysis of real measurements showed that the installation of inverter drives, despite many benefits, as energy savings, that have been reported in the paper, can also cause many problems. We observed multiple issues related to failures in the control and automation systems that could be due to the interference generated by simultaneous operation of inverter drives

    Isotrope Ramanspektroskopie zur Untersuchung schneller Reaktionen - Protonenaustauschreaktionen und Strukturaenderungen von Aminosaeuren in waessrigen Loesungen

    No full text
    SIGLEAvailable from TIB Hannover: DW 7392 / FIZ - Fachinformationszzentrum Karlsruhe / TIB - Technische InformationsbibliothekDEGerman

    Assessing the benefits and risks of application of inverter drives in industry

    No full text
    This paper presents the impact assessment of converters installed in an industrial plant on the power quality in internal power grid of the plant. The analysis of real measurements showed that the installation of inverter drives, despite many benefits, as energy savings, that have been reported in the paper, can also cause many problems. We observed multiple issues related to failures in the control and automation systems that could be due to the interference generated by simultaneous operation of inverter drives

    Wpływ rodzaju złoża filtracyjnego w układach oczyszczania wody basenowej na jakość popłuczyn

    No full text
    This paper presents the influence of the type of filtration beds, used in swimming pool water treatment systems, on the quality and possibility of reusing the washings. The research covered 4 pool cycles with sand, sand and anthracite, glass and diatomaceous beds. The degree of contamination of washings was assessed on the basis of physical, chemical and bacteriological tests. The possibility of drainage of washings into the natural environment was considered, and the results of the research were compared with the permissible values of pollution indicators for wastewater discharged to water or ground. A direct management of the washings from the analyzed filters proved impossible mainly due to the high content of TSS (total suspended solids) and free chlorine. The washings were sedimented and then the supernatant was stirred intensively. As a result of these processes, the quality of washings was significantly improved. This allowed planning to supplement the pool water installations with systems for washings management.Przedstawiono wpływ rodzaju złóż filtracyjnych, stanowiących wypełnienie filtrów w układach oczyszczania wody basenowej, na jakość i możliwość zagospodarowania popłuczyn. Badaniami objęto 4 obiegi basenowe, w których zastosowano złoża: piaskowe, piaskowo-antracytowe, szklane oraz okrzemkowe. Stopień zanieczyszczenia popłuczyn oceniono na podstawie badań fizyczno-chemicznych i bakteriologicznych próbek popłuczyn. Rozważono możliwość odprowadzania popłuczyn do środowiska naturalnego, a wyniki badań porównano z dopuszczalnymi wartościami wskaźników zanieczyszczeń dla ścieków odprowadzanych do wód lub ziemi. Bezpośrednie zagospodarowanie popłuczyn z analizowanych filtrów okazało się niemożliwe przede wszystkim ze względu na duże zawartości zawiesin ogólnych oraz chloru wolnego. Z tego względu popłuczyny poddano sedymentacji, a wodę nadosadową intensywnemu mieszaniu. W wyniku tych procesów jakość popłuczyn uległa znacznej poprawie. Pozwoliło to planować uzupełnianie instalacji wody basenowej o układy zagospodarowania popłuczyn

    Chlorine contamination in different points of pool - risk analysis for bathers’ health

    No full text
    Stacja oczyszczania i dezynfekcji wody basenowej spełnia swoje zadanie pod warunkiem współpracy systemu hydraulicznego z odpowiednią geometrią niecki basenowej. Przepływ wody przez nieckę basenu może powodować powstawanie „martwych” stref niebiorących udziału w cyrkulacji. W strefach tych różny może być stopień wymieszania dezynfektanta z wodą. Tym samym różna może być skuteczność dezaktywacji mikroorganizmów i wpływ na zdrowie osób kąpiących się. Przedstawiono wyniki fizyczno-chemicznych badań próbek wody basenowej pobranych z charakterystycznych punktów niecki. Szczególną uwagę zwrócono na zawartość chloru wolnego i chloru związanego. Badania przeprowadzono w dwóch krytych basenach różniących się systemem przepływu wody. Na podstawie wyników analiz sporządzono mapy chloru dla niecek basenowych. Wykazano, że dla oceny ryzyka zagrożenia zdrowia osób kąpiących się próbki wody powinny być pobierane z punktów niecki basenowej uznanych za reprezentatywne.The pool water treatment and disinfection plant fulfills its task, if the hydraulic system cooperates with the appropriate pool basin geometry. Water flow through the pool can cause “dead” zones not involved in circulation. In these zones the degree of mixing the disinfectant with water can be different. In consequence, the effectiveness of microorganisms’ deactivation and the health effects of bathers may be different. The physicochemical results of pool water samples taken from the characteristic points of the basin were presented. Attention has been paid to the content of free chlorine and combined chlorine. The study was conducted in two indoor pools, differing in water flow. Based on the analysis results, chlorine maps for swimming pools were prepared. It has been shown that in order to assess the health risk to bathers samples of water should be collected from representative points of pool

    The occurence of micropollutants from PPCPs macrogroup in swimming pool water

    No full text
    Utrzymywanie mikrobiologicznej jakości wody basenowej, mające na celu zahamowania rozprzestrzeniania się zakażeń i chorób, jest priorytetem dla wszystkich właścicieli i zarządców basenów. Istnieje wiele środków dezynfekcyjnych stosowanych w basenach, które mogą potencjalnie powodować produkcję szerokiej gamy ubocznych produktów dezynfekcji (DBP). Mikrozanieczyszczenia te powstają na skutek reakcji z organicznymi i nieorganicznymi substancjami wprowadzanymi na obiekty przez ich użytkowników. Oprócz wielu ubocznych produktów dezynfekcji, w wodzie basenowej współcześnie identyfikowane są również mikrozanieczyszczenia z makrogrupy PPCPs (ang. Pharmaceuticals and Personal Care Products). Przeprowadzone w pracy chromatograficzne analizy jakościowe wody pobranej z niecki basenu szkolnego wykazały obecność ponad 100 różnych mikrozanieczyszczeń, niezidentyfikowanych dotychczas w tym środowisku, m.in. leków, hormonów, witamin, domieszek przemysłowych czy też składników kosmetyków. Do identyfikacji związków zastosowano metodę chromatografii gazowej z detekcją mas GC-MS z jonizacją elektronową poprzedzoną ekstrakcją do fazy stałej SPE (ang. Solid Phase Extraction).Maintaining the microbial water quality in order to inhibit the spread of infections and diseases is the priority for every swimming pool owners and managers. There is a number of disinfectants that have been used for swimming pool, which potentially produce a wide range of disinfection by-products (DBPs). These micropollutants are produced by reaction with organic and inorganic matter entering swimming pools by their users. Besides DBPs there are many others micropollutants from PPCPs macro group (Pharmaceuticals and Personal Care Products) that are nowadays identified in swimming pool water. This article describes research conducted on the school swimming pool water. Qualitative chromatographic analysis have shown the presence of more than 100 micropollutants that have not been identified in these environment yet, including medicines, hormones, vitamins, industrial admixtures or cosmetic ingredients. Gas chromatography with GC-MS detection and electron ionization followed by SPE (Solid Phase Extraction) was used to identify the compounds

    Zawartość chloru w różnych punktach niecki basenowej – analiza ryzyka dla zdrowia kąpiących się

    No full text
    The pool water treatment and disinfection plant fulfills its task only if the hydraulic system cooperates with the appropriate pool basin geometry. Water flow through the pool can cause “dead” zones not involved in circulation. In these zones the degree of mixing the disinfectant with water can be different. In consequence, the effectiveness of microorganisms’ deactivation and the health effects on bathers may be different. The physicochemical results of pool water samples taken from the characteristic points of the basin were presented. Attention has been paid to the content of free chlorine and combined chlorine. The study was conducted in two indoor pools, differing in water flow system. Based on the analysis results, chlorine maps for swimming pools were prepared. It has been shown that in order to assess the health risk to bathers samples of water should be collected from representative points of the pool.Stacja oczyszczania i dezynfekcji wody basenowej spełnia swoje zadanie pod warunkiem współpracy systemu hydraulicznego z odpowiednią geometrią niecki basenowej. Przepływ wody przez nieckę basenu może powodować powstawanie „martwych” stref niebiorących udziału w cyrkulacji. W strefach tych różny może być stopień wymieszania dezynfektanta z wodą. Tym samym różna może być skuteczność dezaktywacji mikroorganizmów i wpływ na zdrowie osób kąpiących się. Przedstawiono wyniki fizyczno-chemicznych badań próbek wody basenowej pobranych z charakterystycznych punktów niecki. Szczególną uwagę zwrócono na zawartość chloru wolnego i chloru związanego. Badania przeprowadzono w dwóch krytych basenach różniących się systemem przepływu wody. Na podstawie wyników analiz sporządzono mapy chloru dla niecek basenowych. Wykazano, że do oceny ryzyka zagrożenia zdrowia osób kąpiących się próbki wody powinny być pobierane z punktów niecki basenowej uznanych za reprezentatywne