181 research outputs found

    Unrestricted Utilization of Sirolimus-Eluting Stents in the “Real World”: The Rapamycin-Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry

    Get PDF
    __Abstract_ In-stent restenosis has long been considered the main limitation hampering the long-term efficacy of coronary stenting. Although stent implantation itself has been associated with reduced rates of restenosis compared to balloon angioplasty, in-stent restenosis still persists in up to 40% of patients with complex presentations. Even though a number of “predictors” of restenosis are known and are helpful in characterizing “high-risk” populations, the incidence of restenosis remains largely unpredictable in an individual basis. In addition to its relatively high rate in some subsets, the treatment of restenosis has been proven to be frequently challenging. In-stent restenosis in its more complex forms may re-occur in up to 80% of patients fo

    Influence of dietary Chlorella vulgaris and carbohydrate-active enzymes on growth performance, meat quality and lipid composition of broiler chickens

    Get PDF
    Article in pressHerein, we investigated the effect of Chlorella vulgaris as ingredient (10% of incorporation) in broiler diets, supplemented or not with 2 formulations of Carbohydrate-Active enZymes (CAZymes; Rovabio Excel AP and a mixture of recombinant CAZymes, composed by an exo-b-glucosaminidase, an alginate lyase, a peptidoglycan N-acetylmuramic acid deacetylase and a lysozyme), on growth performance, meat quality, fatty acid composition, oxidative stability, and sensory traits. One hundred twenty 1-day-old Ross 308 male birds were randomly assigned to one of the 4 experimental diets (n 5 30): corn-soybean meal–basal diet (control), basal diet with 10% C. vulgaris (CV), CV supplemented with 0.005% of a commercialCAZymecocktail (Rovabio Excel AP), (CV1R), and CV supplemented with 0.01% of a 4- CAZyme mixture previously selected (CV 1 M) during the experimental period lasted from day 21 to day 35. Body weight gain and feed conversion rate of broilers were not affected by C. vulgaris but digesta viscosity increased more than 2-fold (P , 0.001) relative to the control. In addition, neither cooking loss, shear force, juiciness, flavor nor off-flavor was impaired by dietary treatments (P.0.05). By contrast, the dietary C. vulgaris increased tenderness, yellowness (b*) and total carotenoids in breast and thigh meats. However, no additional protective effect against lipid oxidation was observed in meat with the inclusion of microalga. Chlorella vulgaris, independently of CAZymes, had a minor impact on meat fatty acid composition but improved the proportion of some beneficial fatty acids. In summary, our data indicate a slight improvement of broiler meat quality and lipid nutritional value, without impairment of broilers’ growth performance, thus supporting the usefulness of this microalga in poultry diets, up to this high level of incorporation. By contrast, the selected CAZyme mixtures used do not significantly improve the release of microalga nutrients in poultry diets, through the disruption of microalga cell wall, which warrants further researchinfo:eu-repo/semantics/acceptedVersio

    One year cost effectiveness of sirolimus eluting stents compared with bare metal stents in the treatment of single native de novo coronary lesions: an analysis from the RAVEL trial

    Get PDF
    OBJECTIVE: To assess the balance between costs and effects of the sirolimus eluting stent in the treatment of single native de novo coronary lesions in the RAVEL (randomised study with the sirolimus eluting Bx Velocity balloon expandable stent in the treatment of patients with de novo native coronary artery lesions) study. DESIGN: Multicentre, double blind, randomised trial. SETTING: Percutaneous coronary intervention for single de novo coronary lesions. PATIENTS: 238 patients with stable or unstable angina. INTERVENTIONS: Randomisation to sirolimus eluting stent or bare stent implantation. MAIN OUTCOME MEASURES: Patients were followed up to one year and the treatment effects were expressed as one year survival free of major adverse cardiac events (MACE). Costs were estimated as the product of resource utilisation and Dutch unit costs. RESULTS: At one year, the absolute difference in MACE-free survival was 23% in favour of the sirolimus eluting stent group. At the index procedure, sirolimus eluting stent implantation had an estimated additional procedural cost of 1286. At one year, however, the estimated additional cost difference had decreased to 54 because of the reduction in the need for repeat revascularisations in the sirolimus group (0.8% v 23.6%; p < 0.01). After adjustment of actual results for the consequences of angiographic follow up (correction based on data from the BENESTENT (Belgium Netherlands stent) II study), the difference in MACE-free survival was estimated at 11.1% and the addit

    Sustained safety and performance of the second-generation drug-eluting absorbable metal scaffold in patients with de novo coronary lesions: 12-month clinical results and angiographic findings of the BIOSOLVE-II first-in-man trial.

    Get PDF
    Metal absorbable scaffolds constitute a conceptually attractive alternative to polymeric scaffolds. Promising 6-month outcomes of a second-generation drug-eluting absorbable metal scaffold (DREAMS 2G), consisting of an absorbable magnesium scaffold backbone, have been reported. We assessed the 12-month safety and performance of this novel device. The prospective, international, multi-centre, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to two de novo lesions with a reference diameter between 2.2 and 3.7 mm. All patients were scheduled for angiographic follow-up at 6 months, and-if subjects consented-at 12 months. Dual antiplatelet therapy was recommended for 6 months. Quantitative coronary angiography (QCA) parameters remained stable from 6 to 12 months [paired data of 42 patients: in-segment late lumen loss 0.20 ± 0.21 mm vs. 0.25 ± 0.22 mm, P = 0.117, Δ 0.05 ± 0.21 mm (95% CI: -0.01;0.12); in-scaffold late lumen loss 0.37 ± 0.25 mm vs. 0.39 ± 0.27 mm, P = 0.446, Δ 0.03 ± 0.22 (95% CI: -0.04;0.10), respectively]. Intravascular ultrasound and optical coherence tomography findings corroborated the QCA results. Target lesion failure occurred in four patients (3.4%), consisting of one death of unknown cause, one target-vessel myocardial infarction, and two clinically driven target lesion revascularization. No additional event occurred beyond the 6-month follow-up. During the entire follow-up of 12 months, none of the patients experienced a definite or probable scaffold thrombosis. The novel drug-eluting metal absorbable scaffold DREAMS 2G showed a continuous favourable safety profile up to 12 months and stable angiographic parameters between 6 and 12 months. NCT01960504

    Prevalence, predictors, and prognostic implications of residual impairment of functional capacity after transcatheter aortic valve implantation

    Get PDF
    Background: Patients with degenerative aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI) typically have advanced cardiac and vascular adverse remodeling and multiple comorbidities and, therefore, might not recover a normal functional capacity after valve replacement. We sought to investigate the prevalence, the predictors, and the prognostic impact of residual impairment of functional capacity after TAVI. Methods and results: Out of 790 patients undergoing TAVI with impaired functional capacity (NYHA II–IV

    Clinical, angiographic, and procedural predictors of angiographic restenosis after sirolimus-eluting stent implantation in complex patients

    Get PDF
    BACKGROUND: The factors associated with the occurrence of restenosis after sirolimus-eluting stent (SES) implantation in complex cases are currently unknown. METHODS AND RESULTS: A cohort of consecutive complex patients treated with SES implantation was selected according to the following criteria: (1) treatment of acute myocardial infarction, (2) treatment of in-stent restenosis, (3) 2.25-mm diameter SES, (4) left main coronary stenting, (5) chronic total occlusion, (6) stented segment >36 mm, and (7) bifurcation stenting. The present study population was composed of 238 patients (441 lesions) for whom 6-month angiographic follow-up data were obtained (70% of eligible patients). Significant clinical, angiographic, and procedural predictors of post-SES restenosis were evaluated. Binary in-segment restenosis was diagnosed in 7.9% of lesions (6.3% in-stent, 0.9% at the proximal edge, 0.7% at the distal edge). The following characteristics were identified as independent multivariate predictors: treatment of in-stent restenosis (OR 4.16, 95% CI 1.63 to 11.01; P<0.01), ostial location (OR 4.84, 95% CI 1.81 to 12.07; P<0.01), diabetes (OR 2.63, 95% CI 1.14 to 6.31; P=0.02), total stented length (per 10-mm increase; OR 1.42, 95% CI 1.21 to 1.68; P<0.01), reference diameter (per 1.0-mm increase; OR 0.46, 95% CI 0.24 to 0.87; P=0.03), and left anterior descending artery (OR 0.30, 95% CI 0.10 to 0.69; P<0.01). CONCLUSIONS: Angiographic restenosis after SES implantation in complex patients is an infrequent event, occurring mainly in association with lesion-based characteristics and diabetes mellitus

    Three-dimensional reconstruction of coronary arteries and plaque morphology using CT angiography - comparison and registration with IVUS

    Get PDF
    Background: The aim of this study is to present a new methodology for three-dimensional (3D) reconstruction of coronary arteries and plaque morphology using Computed Tomography Angiography (CTA). Methods: The methodology is summarized in six stages: 1) pre-processing of the initial raw images, 2) rough estimation of the lumen and outer vessel wall borders and approximation of the vessel's centerline, 3) manual adaptation of plaque parameters, 4) accurate extraction of the luminal centerline, 5) detection of the lumen - outer vessel wall borders and calcium plaque region, and 6) finally 3D surface construction. Results: The methodology was compared to the estimations of a recently presented Intravascular Ultrasound (IVUS) plaque characterization method. The correlation coefficients for calcium volume, surface area, length and angle vessel were 0.79, 0.86, 0.95 and 0.88, respectively. Additionally, when comparing the inner and outer vessel wall volumes of the reconstructed arteries produced by IVUS and CTA the observed correlation was 0.87 and 0.83, respectively. Conclusions: The results indicated that the proposed methodology is fast and accurate and thus it is likely in the future to have applications in research and clinical arena

    Effectiveness of the sirolimus-eluting stent in the treatment of patients with a prior history of coronary artery bypass graft surgery

    Get PDF
    Objective: Percutaneous coronary intervention in patients with a history of previous coronary artery bypass grafting (CABG) is associated with an increased rate of subsequent adverse events compared to those without prior CABG. We evaluated the impact of utilizing the sirolimus-eluting stent (SES) in this high-risk population. Methods: Since April 2002, SES implantation was utilized as the default strategy for all percutaneous procedures in our hospital. Consecutive patients with a history of previous CABG and de novo lesions (n=47) treated exclusively with SES, were compared to 66 patients who received bare stents in the 6-month period just before SES introduction. Results: There were no significant differences between the groups (SES and bare stent) with respect to baseline clinical or lesion characteristics. The only difference between the groups related to the nominal diameter of stent utilized, which was smaller in the SES group than the bare stent group. (The maximum diameter of SES available was 3.0 mm). At 1 year, the cumulative incidence of major adverse events (defined as death, myocardial infarction, or target vessel revascularization) was significantly lower in the SES group than the bare stent group [8.5 versus 30.3%, hazard ratio 0.37 (95% confidence interval 0.15-0.91); P=0.03]. Conclusions: The utilization of the sirolimus-eluting stent for percutaneous intervention in a high-risk population with a history of previous CABG surgery is associated with a significant reduction in the rate of major adverse cardiac events at 1 year

    Very long sirolimus-eluting stent implantation for de novo coronary lesions.

    Get PDF
    Long-length stenting has a poor outcome when bare metal stents are used. The safety and efficacy of the sirolimus-eluting stent (SES) in long lesions has not been evaluated. Therefore, the aim of the present study was to evaluate the clinical and angiographic outcomes of SES implantation over a very long coronary artery segment. Since April 2002, all patients treated percutaneously at our institution received a SES as the device of choice as part of the Rapamycin Eluting Stent Evaluated At Rotterdam Cardiology Hospital (RESEARCH) registry. During the RESEARCH registry, stents were available in lengths of 8, 18, and 33 mm. The present report includes a predefined study population consisting of patients treated with >36-mm-long stented segments. Patients had a combination of >or=2 overlapping stents at a minimum length of 41 mm (i.e., one 33-mm SES overlapping an 8-mm SES) to treat native de novo coronary lesions. The incidence of major cardiac adverse events (death, nonfatal myocardial infarction, and target lesion revascularization) was evaluated. The study group comprised 96 consecutive patients (102 lesions). Clinical follow-up was available for all patients at a mean of 320 days (range 265 to 442). In all, 20% of long-stented lesions were chronic total occlusions, and mean stented length per lesion was 61.2 +/- 21.4 mm (range 41 to 134). Angiographic follow-up at 6 months was obtained in 67 patients (71%). Binary restenosis rate was 11.9% and in-stent late loss was 0.13 +/- 0.47 mm. At long-term follow-up (mean 320 days), there were 2 deaths (2.1%), and the overall incidence of major cardiac events was 8.3%. Thus, SES implantation appears safe and effective for de novo coronary lesions requiring multiple stent placement over a very long vessel segment
    corecore