110 research outputs found

    Reduced fetal growth velocity and weight loss are associated with adverse perinatal outcome in fetuses at risk of growth restriction.

    Get PDF
    BACKGROUND Although fetal size is associated with adverse perinatal outcome, the relationship between fetal growth velocity and adverse perinatal outcome is unclear. OBJECTIVE This study aimed to evaluate the relationship between fetal growth velocity and signs of cerebral blood flow redistribution, and their association with birthweight and adverse perinatal outcome. STUDY DESIGN This study was a secondary analysis of the TRUFFLE-2 multicenter observational prospective feasibility study of fetuses at risk of fetal growth restriction between 32+0 and 36+6 weeks of gestation (n=856), evaluated by ultrasound biometry and umbilical and middle cerebral artery Doppler. Individual fetal growth velocity was calculated from the difference of birthweight and estimated fetal weight at 3, 2, and 1 week before delivery, and by linear regression of all available estimated fetal weight measurements. Fetal estimated weight and birthweight were expressed as absolute value and as multiple of the median for statistical calculation. The coefficients of the individual linear regression of estimated fetal weight measurements (growth velocity; g/wk) were plotted against the last umbilical-cerebral ratio with subclassification for perinatal outcome. The association of these measurements with adverse perinatal outcome was assessed. The adverse perinatal outcome was a composite of abnormal condition at birth or major neonatal morbidity. RESULTS Adverse perinatal outcome was more frequent among fetuses whose antenatal growth was <100 g/wk, irrespective of signs of cerebral blood flow redistribution. Infants with birthweight <0.65 multiple of the median were enrolled earlier, had the lowest fetal growth velocity, higher umbilical-cerebral ratio, and were more likely to have adverse perinatal outcome. A decreasing fetal growth velocity was observed in 163 (19%) women in whom the estimated fetal weight multiple of the median regression coefficient was <-0.025, and who had higher umbilical-cerebral ratio values and more frequent adverse perinatal outcome; 67 (41%; 8% of total group) of these women had negative growth velocity. Estimated fetal weight and umbilical-cerebral ratio at admission and fetal growth velocity combined by logistic regression had a higher association with adverse perinatal outcome than any of those parameters separately (relative risk, 3.3; 95% confidence interval, 2.3-4.8). CONCLUSION In fetuses at risk of late preterm fetal growth restriction, reduced growth velocity is associated with an increased risk of adverse perinatal outcome, irrespective of signs of cerebral blood flow redistribution. Some fetuses showed negative growth velocity, suggesting catabolic metabolism

    Noninvasive high-intensity focused ultrasound treatment of twin-twin transfusion syndrome: A preliminary in vivo study.

    Get PDF
    We investigated the efficacy, maternofetal responses, and safety of using high-intensity focused ultrasound (HIFU) for noninvasive occlusion of placental vasculature compared to sham treatment in anesthetized pregnant sheep. This technique for noninvasive occlusion of placental vasculature may be translatable to the treatment of conditions arising from abnormal placental vasculature, such as twin-twin transfusion syndrome (TTTS). Eleven pregnant sheep were instrumented with maternal and fetal arterial catheters and time-transit flow probes to monitor cardiovascular, acid-base, and metabolic status, and then exposed to HIFU (n = 5) or sham (n = 6) ablation of placental vasculature through the exposed uterine surface. Placental vascular flow was occluded in 28 of 30 targets, and histological examination confirmed occlusion in 24 of 30 targets. In both HIFU and sham exposures, uterine contact reduced maternal uterine artery flow, but delivery of oxygen and glucose to the fetal brain remained normal. HIFU can consistently occlude in vivo placental vessels and ablate blood flow in a pregnant sheep model. Cardiovascular and metabolic fetal responses suggest that the technique is safe in the short term and potentially translatable to human pregnancy

    Maternal and fetal cardiometabolic recovery following ultrasound-guided high-intensity focused ultrasound placental vascular occlusion.

    Get PDF
    High-intensity focused ultrasound (HIFU) is a non-invasive method of selective placental vascular occlusion, providing a potential therapy for conditions such as twin-twin transfusion syndrome. In order to translate this technique into human studies, evidence of prolonged fetal recovery and maintenance of a healthy fetal physiology following exposure to HIFU is essential. At 116 ± 2 days gestation, 12 pregnant ewes were assigned to control ( n = 6) or HIFU vascular occlusion ( n = 6) groups and anaesthetized. Placental blood vessels were identified using colour Doppler ultrasound; HIFU-mediated vascular occlusion was performed through intact maternal skin (1.66 MHz, 5 s duration, in situ ISPTA 1.8-3.9 kW cm-2). Unidentifiable colour Doppler signals in targeted vessels following HIFU exposure denoted successful occlusion. Ewes and fetuses were then surgically instrumented with vascular catheters and transonic flow probes and recovered from anaesthesia. A custom-made wireless data acquisition system, which records continuous maternal and fetal cardiovascular data, and daily blood sampling were used to assess wellbeing for 20 days, followed by post-mortem examination. Based on a comparison of pre- and post-treatment colour Doppler imaging, 100% (36/36) of placental vessels were occluded following HIFU, and occlusion persisted for 20 days. All fetuses survived. No differences in maternal or fetal blood pressure, heart rate, heart rate variability, metabolic status or oxygenation were observed between treatment groups. There was evidence of normal fetal maturation and no evidence of chronic fetal stress. There were no maternal injuries and no placental vascular haemorrhage. There was both a uterine and fetal burn, which did not result in any obstetric or fetal complications. This study demonstrates normal long-term recovery of fetal sheep from exposure to HIFU-mediated placental vascular occlusion and underlines the potential of HIFU as a potential non-invasive therapy in human pregnancy

    The stroke oxygen pilot study: a randomized control trial of the effects of routine oxygen supplementation early after acute stroke--effect on key outcomes at six months

    Get PDF
    Introduction: Post-stroke hypoxia is common, and may adversely affect outcome. We have recently shown that oxygen supplementation may improve early neurological recovery. Here, we report the six-month outcomes of this pilot study. Methods: Patients with a clinical diagnosis of acute stroke were randomized within 24 h of admission to oxygen supplementation at 2 or 3 L/min for 72 h or to control treatment (room air). Outcomes (see below) were assessed by postal questionnaire at 6 months. Analysis was by intention-to-treat, and statistical significance was set at p#0.05. Results: Out of 301 patients randomized two refused/withdrew consent and 289 (148 in the oxygen and 141 in the control group) were included in the analysis: males 44%, 51%; mean (SD) age 73 (12), 71 (12); median (IQR) National Institutes of Health Stroke Scale score 6 (3, 10), 5 (3, 10) for the two groups respectively. At six months 22 (15%) patients in the oxygen group and 20 (14%) in the control group had died; mean survival in both groups was 162 days (p= 0.99). Median (IQR) scores for the primary outcome, the modified Rankin Scale, were 3 (1, 5) and 3 (1, 4) for the oxygen and control groups respectively. The covariate-adjusted odds ratio was 1.04 (95% CI 0.67, 1.60), indicating that the odds of a lower (i.e. better) score were non-significantly higher in the oxygen group (p= 0.86). The mean differences in the ability to perform basic (Barthel Index) and extended activities of daily living (NEADL), and quality of life (EuroQol) were also non-significant. Conclusions: None of the key outcomes differed at 6 months between the groups. Although not statistically significant and generally of small magnitude, the effects were predominantly in favour of the oxygen group; a larger trial, powered to show differences in longer-term functional outcomes, is now on-going. Trial Registration: Controlled-Trials.com ISRCTN12362720; Eudract.ema.europa.eu 2004-001866-4

    Antenatal detection of large-for-gestational-age fetuses following implementation of the Growth Assessment Protocol: secondary analysis of a randomised control trial

    Get PDF
    OBJECTIVE: To determine whether the Growth Assessment Protocol (GAP) affects the antenatal detection of large for gestational age (LGA) or maternal and perinatal outcomes amongst LGA babies. DESIGN: Secondary analysis of a pragmatic open randomised cluster control trial comparing the GAP with standard care. SETTING: Eleven UK maternity units. POPULATION: Pregnant women and their LGA babies born at ≥36+0  weeks of gestation. METHODS: Clusters were randomly allocated to GAP implementation or standard care. Data were collected from electronic patient records. Trial arms were compared using summary statistics, with unadjusted and adjusted (two-stage cluster summary approach) differences. MAIN OUTCOME MEASURES: Rate of detection of LGA (estimated fetal weight on ultrasound scan above the 90th centile after 34+0  weeks of gestation, defined by either population or customised growth charts), maternal and perinatal outcomes (e.g. mode of birth, postpartum haemorrhage, severe perineal tears, birthweight and gestational age, neonatal unit admission, perinatal mortality, and neonatal morbidity and mortality). RESULTS: A total of 506 LGA babies were exposed to GAP and 618 babies received standard care. There were no significant differences in the rate of LGA detection (GAP 38.0% vs standard care 48.0%; adjusted effect size -4.9%; 95% CI -20.5, 10.7; p = 0.54), nor in any of the maternal or perinatal outcomes. CONCLUSIONS: The use of GAP did not change the rate of antenatal ultrasound detection of LGA when compared with standard care

    Do differences in diagnostic criteria for late fetal growth restriction matter?

    Get PDF
    Background: Criteria for diagnosis of fetal growth restriction differ widely according to national and international guidelines, and further heterogeneity arises from the use of different biometric and Doppler reference charts, making the diagnosis of fetal growth restriction highly variable. Objective: This study aimed to compare fetal growth restriction definitions between Delphi consensus and Society for Maternal-Fetal Medicine definitions, using different standards/charts for fetal biometry and different reference ranges for Doppler velocimetry parameters. Study design: From the TRUFFLE 2 feasibility study (856 women with singleton pregnancy at 32+0 to 36+6 weeks of gestation and at risk of fetal growth restriction), we selected 564 women with available mid-pregnancy biometry. For the comparison, we used standards/charts for estimated fetal weight and abdominal circumference from Hadlock, INTERGROWTH-21st, and GROW and Chitty. Percentiles for umbilical artery pulsatility index and its ratios with middle cerebral artery pulsatility index were calculated using Arduini and Ebbing reference charts. Sensitivity and specificity for low birthweight and adverse perinatal outcome were evaluated. Results: Different combinations of definitions and reference charts identified substantially different proportions of fetuses within our population as having fetal growth restriction, varying from 38% (with Delphi consensus definition, INTERGROWTH-21st biometric standards, and Arduini Doppler reference ranges) to 93% (with Society for Maternal-Fetal Medicine definition and Hadlock biometric standards). None of the different combinations tested appeared effective, with relative risk for birthweight <10th percentile between 1.4 and 2.1. Birthweight <10th percentile was observed most frequently when selection was made with the GROW/Chitty charts, slightly less with the Hadlock standard, and least frequently with the INTERGROWTH-21st standard. Using the Ebbing Doppler reference ranges resulted in a far higher proportion identified as having fetal growth restriction compared with the Arduini Doppler reference ranges, whereas Delphi consensus definition with Ebbing Doppler reference ranges produced similar results to those of the Society for Maternal-Fetal Medicine definition. Application of Delphi consensus definition with Arduini Doppler reference ranges was significantly associated with adverse perinatal outcome, with any biometric standards/charts. The Society for Maternal-Fetal Medicine definition could not accurately detect adverse perinatal outcome irrespective of estimated fetal weight standard/chart used. Conclusion: Different combinations of fetal growth restriction definitions, biometry standards/charts, and Doppler reference ranges identify different proportions of fetuses with fetal growth restriction. The difference in adverse perinatal outcome may be modest, but can have a significant impact in terms of rate of intervention

    Vasa previa in singleton pregnancies: Diagnosis and clinical management based on an international expert consensus

    Get PDF
    There are limited data to guide the diagnosis and management of vasa previa. Currently, what is known is largely based on case reports or series and cohort studies. (s): To systematically collect and classify expert opinions and achieve consensus on the diagnosis and clinical management of vasa previa using focus group discussions (FGD) and a Delphi technique. A four-round FGD and a three-round Delphi survey of an international panel of experts on vasa previa were conducted. Experts were selected based on their publication record on vasa previa. First, we convened an FGD panel of 20 experts and agreed on which issues were unresolved in the diagnosis and management of vasa previa. A three-round anonymous electronic survey was then sent to the full expert panel. Survey questions were presented on the diagnosis and management of vasa previa that the experts were asked to rate on a 5-point Likert scale (from strongly disagree = 1 to strongly agree = 5). Consensus was defined as a median score of 5. Following responses to each round, any statements that had median scores of 3 or less were deemed to have had no consensus and excluded. Statements with a median score of 4 were revised and re-presented to the experts in the next round. Consensus and non-consensus statements were then aggregated. Sixty-eight international experts were invited to participate in the study, of which 57 participated. Experts were from 13 countries on five continents and have contributed to over 80% of published cohort studies on vasa previa, as well as national and international society guidelines. Completion rates were 84%, 93%, 91% for the first, second, and third rounds, respectively, and 71% completed all three rounds. The panel reached a consensus on 26 statements regarding the diagnosis and key points of management of vasa previa, including: 1) While there is no agreement on a distance between the fetal vessels and the cervical internal os to define vasa previa, the definition should not be limited to a 2 cm distance; 2) All pregnancies should be screened for vasa previa with routine examination for placental cord insertion and a color Doppler sweep of the region over the cervix at the second-trimester anatomy scan; 3) When a low-lying placenta or placenta previa is found in the second trimester, a transvaginal ultrasound with Doppler should be performed at around 32 weeks to rule out vasa previa; 4) Outpatient management of asymptomatic patients without risk factors for preterm birth is reasonable; 5)Asymptomatic patients with vasa previa should be delivered by scheduled cesarean between 35- and 37-weeks of gestation; and 6) There was no agreement on routine hospitalization, avoidance of intercourse, or use of 3-dimensional ultrasound for diagnosis of vasa previa. Through FGD and a Delphi process, an international expert panel reached consensus on the definition, screening, clinical management, and timing of delivery in vasa previa, which could inform the development of new clinical guidelines. [Abstract copyright: Copyright © 2024. Published by Elsevier Inc.
    • …
    corecore