2,547 research outputs found

    Image Segmentation by Edge Partitioning over a Nonsubmodular Markov Random Field

    Get PDF
    Edge weight-based segmentation methods, such as normalized cut or minimum cut, require a partition number specification for their energy formulation. The number of partitions plays an important role in the segmentation overall quality. However, finding a suitable partition number is a nontrivial problem, and the numbers are ordinarily manually assigned. This is an aspect of the general partition problem, where finding the partition number is an important and difficult issue. In this paper, the edge weights instead of the pixels are partitioned to segment the images. By partitioning the edge weights into two disjoints sets, that is, cut and connect, an image can be partitioned into all possible disjointed segments. The proposed energy function is independent of the number of segments. The energy is minimized by iterating the QPBO-α-expansion algorithm over the pairwise Markov random field and the mean estimation of the cut and connected edges. Experiments using the Berkeley database show that the proposed segmentation method can obtain equivalently accurate segmentation results without designating the segmentation numbers

    Observation of inductively coupled-plasma-induced damage on n-type GaN using deep-level transient spectroscopy

    Get PDF
    The effects of inductively coupled plasma (ICP) etching on electrical properties of n-type GaN Schottky contacts were investigated by observing ion damage using deep-level transient spectroscopy. An electron trap, not previously seen, localized near the contact, as well as a pre-existing trap, was observed in the ICP-etched sample. The ICP-etched surface was found to be N-deficient, which means that N vacancies (V-N) were produced by ICP etching. From these, the origin of the ICP-induced electron trap was suggested to be V-N or a V-N-related complex of point defects. The ICP-induced traps provided a path for the transport of electrons, leading to the reduction of Schottky barrier height and increase of gate leakage current.open273

    Solid–liquid interface temperature measurement of evaporating droplet using thermoresponsive polymer aqueous solution

    Get PDF
    The present study aims to measure the solid–liquid interface temperature of an evaporating droplet on a heated surface using a thermoresponsive polymer. Poly(N-isopropylacrylamide) (pNIPAM) was used owing to its sensitive optical and mechanical properties to the temperature. We also measured the refractive index variation of the pNIPAM solution by using the surface plasmon resonance imaging (SPRi). In particular, the present study proposed a new method to measure the solid–liquid interface temperature using the correlation among reflectance, refractive index, and temperature. It was found that the reflectance of a pNIPAM solution decreased after the droplet deposition. The solid–liquid interface temperature, estimated from the reflectance, showed a lower value at the center of the droplet, and it gradually increased along the radial direction. The lowest temperature at the contact line region is present because of the maximum evaporative cooling. Moreover, the solid–liquid interface temperature deviation increased with the surface temperature, which means solid–liquid interface temperature should be considered at high temperature to predict the evaporation flux of the droplet accurately

    Undifferentiated embryonal sarcoma of the liver in an adult patient

    Get PDF
    Undifferentiated embryonal sarcoma of the liver (UESL) is rare primary hepatic sarcoma and is known to occur in pediatric patients. This case is the UESL occurred in a 51-year old male patient. Multilocular cystic lesion was composed of primitive spindle cells without specific differentiation. This rare case would help to review differential diagnosis of primary sarcoma in liver and cystic neoplasm of the liver

    The Effect of Ca-P Coated Bovine Bone Mineral on Bone Regeneration around Dental Implant in Dogs

    Get PDF
    There are many obstacles to overcome in implant dentistry. The bony defect around implant can be seen in immediate installation procedures. Following tooth extraction, however, a socket often presents dimensions that may be considerably greater than the dimensions of a conventional implant
    corecore