28 research outputs found

    Similar glycaemic control and less hypoglycaemia during active titration after insulin initiation with glargine 300 units/mL and degludec 100 units/mL: A subanalysis of the BRIGHT study

    Get PDF
    Aim: To further investigate glycaemic control and hypoglycaemia in BRIGHT, focusing on the titration period. Materials and Methods: BRIGHT was a multicentre, open-label, randomized, active-controlled, two-arm, parallel-group, 24-week study in insulin-naïve patients with uncontrolled type 2 diabetes initiated on glargine 300 U/mL (Gla-300) (N = 466) or degludec (IDeg-100) (N = 463). Predefined efficacy and safety outcomes were investigated during the initial 12-week titration period. In addition, patients’ characteristics and clinical outcomes were assessed descriptively, stratified by confirmed (≤3.9 mmol/L) hypoglycaemia incidence during the initial titration period. Results: At week 12, HbA1c was comparable between Gla-300 (7.32%) and IDeg-100 (7.23%), with similar least squares (LS) mean reductions from baseline (−1.37% and − 1.39%, respectively; LS mean difference of 0.02; 95% confidence interval: −0.08 to 0.12). Patients who experienced hypoglycaemia during the initial titration period had numerically greater HbA1c reductions by week 12 than patients who did not (−1.46% vs. −1.28%), and higher incidence of anytime (24 hours; 73.3% vs. 35.7%) and nocturnal (00:00–06:00 hours; 30.0% vs. 11.9%) hypoglycaemia between weeks 13–24. Conclusions: The use of Gla-300 resulted in similar glycaemic control as IDeg-100 during the initial 12-week titration period of the BRIGHT study, when less anytime (24 hours) hypoglycaemia with Gla-300 versus IDeg-100 has been reported. Experiencing hypoglycaemia shortly after initiating Gla-300 or IDeg-100 may be associated with hypoglycaemia incidence in the longer term, potentially impacting glycaemic management

    Designer Gene Delivery Vectors: Molecular Engineering and Evolution of Adeno-Associated Viral Vectors for Enhanced Gene Transfer

    Get PDF
    Gene delivery vectors based on adeno-associated virus (AAV) are highly promising due to several desirable features of this parent virus, including a lack of pathogenicity, efficient infection of dividing and non-dividing cells, and sustained maintenance of the viral genome. However, several problems should be addressed to enhance the utility of AAV vectors, particularly those based on AAV2, the best characterized AAV serotype. First, altering viral tropism would be advantageous for broadening its utility in various tissue or cell types. In response to this need, vector pseudotyping, mosaic capsids, and targeting ligand insertion into the capsid have shown promise for altering AAV specificity. In addition, library selection and directed evolution have recently emerged as promising approaches to modulate AAV tropism despite limited knowledge of viral structure–function relationships. Second, pre-existing immunity to AAV must be addressed for successful clinical application of AAV vectors. “Shielding” polymers, site-directed mutagenesis, and alternative AAV serotypes have shown success in avoiding immune neutralization. Furthermore, directed evolution of the AAV capsid is a high throughput approach that has yielded vectors with substantial resistance to neutralizing antibodies. Molecular engineering and directed evolution of AAV vectors therefore offer promise for generating ‘designer’ gene delivery vectors with enhanced properties

    The multiple facets of drug resistance: one history, different approaches

    Full text link

    Similar glycaemic control and less hypoglycaemia during active titration after insulin initiation with glargine 300 units/mL and degludec 100 units/mL: A subanalysis of the BRIGHT study.

    Get PDF
    AIM: To further investigate glycaemic control and hypoglycaemia in BRIGHT, focusing on the titration period. MATERIALS AND METHODS: BRIGHT was a multicentre, open-label, randomized, active-controlled, two-arm, parallel-group, 24-week study in insulin-naïve patients with uncontrolled type 2 diabetes initiated on glargine 300 U/mL (Gla-300) (N = 466) or degludec (IDeg-100) (N = 463). Predefined efficacy and safety outcomes were investigated during the initial 12-week titration period. In addition, patients' characteristics and clinical outcomes were assessed descriptively, stratified by confirmed (≤3.9 mmol/L) hypoglycaemia incidence during the initial titration period. RESULTS: At week 12, HbA1c was comparable between Gla-300 (7.32%) and IDeg-100 (7.23%), with similar least squares (LS) mean reductions from baseline (-1.37% and - 1.39%, respectively; LS mean difference of 0.02; 95% confidence interval: -0.08 to 0.12). Patients who experienced hypoglycaemia during the initial titration period had numerically greater HbA1c reductions by week 12 than patients who did not (-1.46% vs. -1.28%), and higher incidence of anytime (24 hours; 73.3% vs. 35.7%) and nocturnal (00:00-06:00 hours; 30.0% vs. 11.9%) hypoglycaemia between weeks 13-24. CONCLUSIONS: The use of Gla-300 resulted in similar glycaemic control as IDeg-100 during the initial 12-week titration period of the BRIGHT study, when less anytime (24 hours) hypoglycaemia with Gla-300 versus IDeg-100 has been reported. Experiencing hypoglycaemia shortly after initiating Gla-300 or IDeg-100 may be associated with hypoglycaemia incidence in the longer term, potentially impacting glycaemic management
    corecore