18 research outputs found

    Liver stiffness in nonalcoholic fatty liver disease: A comparison of supersonic shear imaging, FibroScan, and ARFI with liver biopsy

    Get PDF
    Nonalcoholic fatty liver disease (NAFLD) has become a major public health issue. The goal of this study was to assess the clinical use of liver stiffness measurement (LSM) evaluated by supersonic shear imaging (SSI), FibroScan, and acoustic radiation force impulse (ARFI) in a cohort of NAFLD patients who underwent liver biopsy. A total of 291 NAFLD patients were prospectively enrolled from November 2011 to February 2015 at 2 French university hospitals. LSM was assessed by SSI, FibroScan (M probe), and ARFI within two weeks prior to liver biopsy. Calculations of the area under the receiver operating curve (AUROC) were performed and compared for the staging of liver fibrosis. AUROC for SSI, FibroScan, and ARFI were 0.86, 0.82, and 0.77 for diagnoses of ≄F2; 0.89, 0.86, and 0.84 for ≄F3; and 0.88, 0.87, and 0.84 for F4, respectively. SSI had a higher accuracy than ARFI for diagnoses of significant fibrosis (≄F2) (P = 0.004). Clinical factors related to obesity such as body mass index ≄ 30 kg/m(2) , waist circumference ≄102 cm or increased parietal wall thickness were associated with LSM failures when using SSI or FibroScan and with unreliable results when using ARFI. In univariate analysis, FibroScan values were slightly correlated with NAFLD activity score and steatosis (R = 0.28 and 0.22, respectively), whereas SSI and ARFI were not; however, these components of NAFLD did not affect LSM results in multivariate analysis. The cutoff values for SSI and FibroScan for staging fibrosis with a sensitivity ≄90% were very close: 6.3/6.2 kPa for ≄F2, 8.3/8.2 kPa for ≄F3, and 10.5/9.5 kPa for F4. CONCLUSION: Although obesity is associated with an increase in LSM failure, the studied techniques and especially SSI provide high value for the diagnosis of liver fibrosis in NAFLD patients. (Hepatology 2016;63:1817-1827)

    Criteria to Determine Reliability of Noninvasive Assessment of Liver Fibrosis With Virtual Touch Quantification

    Get PDF
    BACKGROUND & AIMS: Virtual Touch Quantification (VTQ) evaluates liver fibrosis in patients with chronic liver diseases by measuring shear wave speed in the liver. We aimed to determine the reliability criteria of VTQ examination. METHODS: We performed a prospective study of 1094 patients with chronic liver disease from November 2009 through October 2016 at Angers University Hospital, and between April 2010 and May 2015 at Bordeaux University Hospital, in France. All patients underwent liver biopsy analysis (reference standard), and VTQ examination was made by experienced operators on the same day, or no more than 3 months before or afterward. Advanced liver fibrosis was defined as fibrosis stage F ≄ 3 according to the scoring system of the Nonalcoholic Steatohepatitis Clinical Research Network, or fibrosis stage F ≄ 2 according to the Metavir scoring system. The diagnostic accuracy of VTQ in detection of advanced fibrosis or cirrhosis was assessed using the area under the receiver operating characteristic (AUROC) and the rate of correctly classiïŹed patients. Reliability criteria were defined from the intrinsic characteristics of VTQ examination, which were shown to influence the diagnostic accuracy. RESULTS: VTQ identified patients with advanced fibrosis with an AUROC of 0.773 ± 0.014 and correctly classified 72.0% of patients using a diagnostic cut-off value of 1.37 m/s. VTQ identified patients with cirrhosis with an AUROC value of 0.839 ± 0.014 and correctly classified 78.4% of patients using a cut-off value of 1.87 m/s. The reliability of VTQ decreased with an increasing ratio of interquartile range/median (IQR/M) in patients with intermediate-high VTQ results. We defined 3 reliability categories for VTQ: unreliable (IQR/M ≄0.35 with VTQ result ≄1.37 m/s), reliable (IQR/M ≄0.35 with VTQ result <1.37 m/s or IQR/M 0.15-0.34), and very reliable (IQR/M <0.15). For advanced fibrosis, VTQ correctly classified 57.8% of patients in the unreliable group, 73.7% of patients in the reliable group, and 80.9% of patients in the very reliable group (P < .001); for cirrhosis, these values were 50.0%, 83.4%, and 92.6%, respectively (P < .001). Of the VTQ examinations made, 21.4% were unreliable, 55.0% were reliable, and 23.6% were very reliable. The skin-liver capsule distance was independently associated with an unreliable VTQ examination, which occurred in 52.7% of patients with a distance of 30 mm or more. CONCLUSIONS: In a study to determine the reliability of VTQ findings, compared with results from biopsy analysis, we assigned VTQ examinations to 3 categories (unreliable, reliable, and very reliable). VTQ examinations with IQR/M ≄0.35 and ≄1.37 m/s had very low diagnostic accuracy. Our reliability criteria for liver fibrosis assessment with VTQ will help physicians to accurately evaluate the severity of chronic liver diseases and monitor their progression

    Annualisation des volumes des services d'alimentation en eau potable

    No full text
    International audienceSMEGREG is a public body in charge of water saving in the Gironde département (French administrative unit) in southwest France. SMEGREG has devised its own information system to collate water balance component data from all utilities in the region. Analysis of those data highlighted numerous disparities in the methods used by different utilities to calculate annual volumes. At the request of SMEGREG, Irstea carried out a detailed study of the practices of five drinking water utilities. The process used to estimate volumes is referred to as "annualisation". The annualisation process can be broken down into three main steps: 1) Determining a representative date for Customer meter readings, 2) Adjusting volumes measured by main meters, 3) Adjusting metered consumption to fit a calendar year. There are several possible methods of carrying out each of these steps. In this research project, all methods were applied to each utility under study. Calculations show that annualisation methods have a strong impact on volume estimates. At the end of this study, SMEGREG made two strong recommendations to data providers: 1) Annualisation methods must be identified, and all calculations must be reproducible, 2) The same combination of methods should be used every year

    Modeling and Unsupervised Classification of Multivariate Hidden Markov Chains With Copulas

    No full text
    Abstract—Parametric modeling and estimation of non-Gaussian multidimensional probability density function is a difficult problem whose solution is required by many applications in signal and image processing. A lot of efforts have been devoted to escape the usual Gaussian assumption by developing perturbed Gaussian models such as Spherically Invariant Random Vectors (SIRVs). In this work, we introduce an alternative solution based on copulas that enables theoretically to represent any multivariate distribution. Estimation procedures are proposed for some mixtures of copula-based densities and are compared in the hidden Markov chain setting, in order to perform statistical unsupervised classification of signals or images. Useful copulas and SIRV for multivariate signal classification are particularly studied through experiments Index Terms—Copulas, EM algorithm, hidden Markov chains, hidden Markov models, inference for margins, maximum likelihood, multivariate modeling, spherically invariant random vector (SIRV), statistical classification. I

    Modeling and Unsupervised Classification of Multivariate Hidden Markov Chains With Copulas

    No full text

    Comparison of perfused volume segmentation between cone-beam CT and 99mTc-MAA SPECT/CT for treatment dosimetry before selective internal radiation therapy using 90Y-glass microspheres

    No full text
    International audiencePurpose: To compare the reliability and accuracy of the pre-treatment dosimetry predictions using cone-beam computed tomography (CBCT) versus 99mTc-labeled macroaggregated albumin (MAA) SPECT/CT for perfused volume segmentation in patients with hepatocellular carcinoma treated by selective internal radiation therapy (SIRT) using 90Y-glass microspheres.Materials and methods: Fifteen patients (8 men, 7 women) with a mean age of 68.3±10.5 (SD) years (range: 47-82 years) who underwent a total of 17 SIRT procedures using 90Y-glass microspheres for unresectable hepatocellular carcinoma were retrospectively included. Pre-treatment dosimetry data were calculated from 99mTc-MAA SPECT/CT using either CBCT or 99mTc-MAA SPECT/CT to segment the perfused volumes. Post-treatment dosimetry data were calculated using 90Y imaging (SPECT/CT or PET/CT). The whole liver, non-tumoral liver, and tumor volumes were segmented on CT or MRI data. The mean absorbed doses of the tumor (DT), non-tumoral liver, perfused liver (DPL) and perfused non-tumoral liver were calculated. Intra- and interobserver reliabilities were investigated by calculating Lin's concordant correlation coefficients (ρc values). The differences (biases) between pre- and post-treatment dosimetry data were assessed using the modified Bland-Altman method (for non-normally distributed variables), and systematic bias was evaluated using Passing-Bablok regression.Results: The intra- and interobserver reliabilities were good-to-excellent (ρc: 0.80-0.99) for all measures using both methods. Compared with 90Y imaging, the median differences were 5.8Gy (IQR: -12.7; 16.1) and 5.6Gy (IQR: -13.6; 10.2) for DPL-CBCT and DPL-99mTc-MAA SPECT/CT, respectively. The median differences were 1.6Gy (IQR: -29; 7.53) and 9.8Gy (IQR: -28.4; 19.9) for DT-CBCT and DT-99mTc-MAA SPECT/CT respectively. Passing-Bablok regression analysis showed that both CBCT and 99mTc-MAA SPECT/CT had proportional biases and thus tendencies to overestimate DT and DPL at higher post-treatment doses.Conclusion: CBCT may be a reliable segmentation method, but it does not significantly increase the accuracy of dose prediction compared with that of 99mTc-MAA SPECT/CT. At higher doses both methods tend to overestimate the doses to tumors and perfused livers

    A radiation-hardened injection locked oscillator devoted to radio-frequency applications

    No full text
    International audienceImplemented in a 0.25mumum SiGe technology, a 5.2 GHz Injection Locked Oscillator (ILO) for Radio-Frequency (RF) applications is shown to be intrinsically radiation-hardened. Design principles and laser-based testing results are presented
    corecore