241 research outputs found

    Study of noise reduction characteristics of composite fiber-reinforced panels, interior panel configurations, and the application of the tuned damper concept

    Get PDF
    The application of fiber reinforced composite materials, such as graphite epoxy and Kevlar, for secondary or primary structures developing in the commercial airplane industry was investigated. A composite panel program was initiated to study the effects of some of the parameters that affect noise reduction of these panels. The fiber materials and the ply orientation were chosen to be variables in the test program. It was found that increasing the damping characteristics of a structural panel will reduce the vibration amplitudes at resonant frequencies with attendant reductions in sound reduction. Test results for a dynamic absorber, a tuned damper, are presented and evaluated

    The effect of oblique angle of sound incidence, realistic edge conditions, curvature and in-plane panel stresses on the noise reduction characteristics of general aviation type panels

    Get PDF
    Experiments and a theoretical analysis were conducted to predict the noise reduction of inclined and curved panels. These predictions are compared to the experimental results with reasonable agreement between theory and experiment for panels under an oblique angle of sound incidence. Theoretical as well as experimental results indicate a big increase in noise reduction when a flat test panel is curved. Further curving the panel slightly decreases the noise reduction. Riveted flat panels are shown to give a higher noise reduction in the stiffness-controlled frequency region, while bonded panels are superior in this region when the test panel is curved. Experimentally measured noise reduction characteristics of flat aluminum panels with uniaxial in-plane stresses are presented and discussed. These test results indicate an important improvement in the noise reduction of these panels in the frequency range below the fundamental panel/cavity frequency

    Development of a thermal and structural model for a NASTRAN finite-element analysis of a hypersonic wing test structure

    Get PDF
    The development of a thermal and structural model for a hypersonic wing test structure using the NASTRAN finite-element method as its primary analytical tool is described. A detailed analysis was defined to obtain the temperature and thermal stress distribution in the whole wing as well as the five upper and lower root panels. During the development of the models, it was found that the thermal application of NASTRAN and the VIEW program, used for the generation of the radiation exchange coefficients, were definicent. Although for most of these deficiencies solutions could be found, the existence of one particular deficiency in the current thermal model prevented the final computation of the temperature distributions. A SPAR analysis of a single bay of the wing, using data converted from the original NASTRAN model, indicates that local temperature-time distributions can be obtained with good agreement with the test data. The conversion of the NASTRAN thermal model into a SPAR model is recommended to meet the immediate goal of obtaining an accurate thermal stress distribution

    Endoanal MRI of the anal sphincter complex: correlation with cross-sectional anatomy and histology

    Get PDF
    The purpose of this study was to correlate the in vivo endoanal MRI findings of the anal sphincter with the cross-sectional anatomy and histology. Fourteen patients with rectal tumours were examined with a rigid endoanal MR coil before undergoing abdominoperineal resection. In addition, 12 cadavers were used to obtain cross-sectional anatomical sections. The images were correlated with the histology and anatomy of the resected rectal specimens as well as with the cross-sectional anatomical sections of the 12 cadavers. The findings in 8 patients, 11 rectal preparations, and 10 cadavers, could be compared. In these cases, there was an excellent correlation between endoanal MRI and the cross-sectional cadaver anatomy and histology. With endoanal MRI, all muscle layers of the anal canal wall, comprising the internal anal sphincter, longitudinal muscle, the external anal sphincter and the puborectalis muscle wer

    Nocturnal foraging lifts time-constraints in winter for migratory geese but hardly speeds up fueling

    Get PDF
    Climate warming advances the optimal timing of breeding for many animals. For migrants to start breeding earlier, a concurrent advancement of migration is required, including premigratory fueling of energy reserves. We investigate whether barnacle geese are time constrained during premigratory fueling and whether there is potential to advance or shorten the fueling period to allow an earlier migratory departure. We equipped barnacle geese with GPS trackers and accelerometers to remotely record birds’ behavior, from which we calculated time budgets. We examined how time spent foraging was affected by the available time (during daylight and moonlit nights) and thermoregulation costs. We used an energetic model to assess onset and rates of fueling and whether geese can further advance fueling by extending foraging time. We show that, during winter, when facing higher thermoregulation costs, geese consistently foraged at night, especially during moonlit nights, in order to balance their energy budgets. In spring, birds made use of the increasing day length and gained body stores by foraging longer during the day, but birds stopped foraging extensively during the night. Our model indicates that, by continuing nighttime foraging throughout spring, geese may have some leeway to advance and increase fueling rate, potentially reaching departure body mass 4 days earlier. In light of rapid climatic changes on the breeding grounds, whether this advancement can be realized and whether it will be sufficient to prevent phenological mismatches remains to be determined

    Climate warming may affect the optimal timing of reproduction for migratory geese differently in the low and high Arctic

    Get PDF
    Rapid climate warming is driving organisms to advance timing of reproduction with earlier springs, but the rate of advancement shows large variation, even among populations of the same species. In this study, we investigated how the rate of advancement in timing of reproduction with a warming climate varies for barnacle goose (Branta leucopsis) populations breeding at different latitudes in the Arctic. We hypothesized that populations breeding further North are generally more time constrained and, therefore, produce clutches earlier relative to the onset of spring than southern populations. Therefore, with increasing temperatures and a progressive relief of time constraint, we expected latitudinal differences to decrease. For the years 2000-2016, we determined the onset of spring from snow cover data derived from satellite images, and compiled data on egg laying date and reproductive performance in one low-Arctic and two high-Arctic sites. As expected, high-Arctic geese laid their eggs earlier relative to snowmelt than low-Arctic geese. Contrary to expectations, advancement in laying dates was similar in high- and low-Arctic colonies, at a rate of 27% of the advance in date of snowmelt. Although advancement of egg laying did not fully compensate for the advancement of snowmelt, geese laying eggs at intermediate dates in the low Arctic were the most successful breeders. In the high Arctic, however, early nesting geese were the most successful breeders, suggesting that high-Arctic geese have not advanced their laying dates sufficiently to earlier springs. This indicates that high-Arctic geese especially are vulnerable to negative effects of climate warming

    Prospective comparative study of spiral computer tomography and magnetic resonance imaging for detection of hepatocellular carcinoma

    Get PDF
    BACKGROUND: Hepatocellular carcinoma (HCC) is often detected at a relatively late stage when tumour size prohibits curative surgery. Screening to detect HCC at an early stage is performed for patients at risk. AIM: The aim of this study was to compare prospectively the diagnostic accuracy and classification for management of the two state of the art secondline imaging techniques: triphasic spiral computer tomography (CT) and super paramagnetic iron oxide (SPIO) enhanced magnetic resonance imaging (MRI). PATIENTS: Sixty one patients were evaluated between January 1996 and January 1998. Patients underwent CT and MRI within a mean interval of 6.75 days. METHODS: CT and MRI were evaluated blindly for the presence and number of lesions, characterisation of these lesions, and classification for management. For comparison of the data on characterisation, the CT and MRI findings were compared with histopathological studies of the surgical specimens and/or follow up imaging. Data of patients not lost to follow up were available to January 2001. RESULTS: SPIO enhanced MRI detected more lesions and overall smaller lesions than triphasic spiral CT (number of lesions 189 v 124; median diameter 1.0 v 1.8 cm; Spearman rank's correlation coefficient 0.63, p<0.001). There was no significant difference in accuracy between CT and MRI for lesion characterisation. The agreement in classification for management was very good (weighted kappa 0.91, 95% CI 0.83-0.99). CONCLUSION: SPIO enhanced MRI detects more and smaller lesions, but both techniques are comparable in terms of classification for management. SPIO enhanced MRI may be preferred as there is no exposure to ionising radiation

    Optimizing imaging in suspected appendicitis (OPTIMAP-study): A multicenter diagnostic accuracy study of MRI in patients with suspected acute appendicitis. Study Protocol

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>In patients with clinically suspected appendicitis, imaging is needed to substantiate the clinical diagnosis. Imaging accuracy of ultrasonography (US) is suboptimal, while the most accurate technique (CT) is associated with cancer related deaths through exposure to ionizing radiation. MRI is a potential replacement, without associated ionizing radiation and no need for contrast medium administration. If MRI is proven to be sufficiently accurate, it could be introduced in the diagnostic pathway of patients with suspected appendicitis, increasing diagnostic accuracy and improving clinical outcomes, without the risk of radiation induced cancer or iodinated contrast medium-related drawbacks. The multicenter OPTIMAP study was designed to estimate the diagnostic accuracy of MRI in patients with suspected acute appendicitis in the general population.</p> <p>Methods/Design</p> <p>Eligible for this study are consecutive patients presenting with clinically suspected appendicitis at the emergency department in six centers. All patients will undergo imaging according to the Dutch guideline for acute appendicitis: initial ultrasonography in all and subsequent CT whenever US does not confirm acute appendicitis. Then MRI is performed in all patients, but the results are not used for patient management. A final diagnosis assigned by an expert panel, based on all available information including 3-months follow-up, except MRI findings, is used as the reference standard in estimating accuracy. We will calculate the sensitivity, specificity, predictive values and inter-observer agreement of MRI, and aim to include 230 patients. Patient acceptance and total imaging costs will also be evaluated.</p> <p>Discussion</p> <p>If MRI is found to be sufficiently accurate, it could replace CT in some or all patients. This will limit or obviate the ionizing radiation exposure associated risk of cancer induction and contrast medium induced nephropathy with CT, preventing the burden and the direct and indirect costs associated with treatment. Based on the high intrinsic contrast resolution of MRI, one might envision higher accuracy rates for MRI than for CT. If so, MRI could further decrease the number of unnecessary appendectomies and the number of missed appendicitis cases.</p> <p>Trial registration</p> <p><b>NTR2148</b></p

    CD1d-Invariant Natural Killer T Cell-Based Cancer Immunotherapy: α-Galactosylceramide and Beyond

    Get PDF
    CD1d-restricted invariant natural killer T (iNKT) cells are considered an attractive target for cancer immunotherapy. Upon their activation by glycolipid antigen and/or cytokines, iNKT cells can induce direct lysis of tumor cells but can also induce an antitumor immune response via their rapid production of proinflammatory cytokines that trigger the cytotoxic machinery of other components of the innate and adaptive immune system. Here, we provide an overview of various therapeutic approaches that have been evaluated or that are currently being developed and/or explored. These include administration of α-GalCer or alternative (glyco) lipid antigens, glycolipid-loaded antigen-presenting cells and liposomes, strategies that enhance CD1d expression levels or are based on ligation of CD1d, adoptive transfer of iNKT cells or chimeric antigen receptor iNKT cells, and tumor targeting of iNKT cells
    • …
    corecore