29 research outputs found
Chemotherapy-related complications in the kidneys and collecting system: an imaging perspective
Nephrotoxicity is a common adverse effect of many chemotherapeutic agents. The agents most commonly associated with chemotherapy-associated nephrotoxicity are methotrexate, semustine, streptozocin, mithramycin, and cisplatin. Certain chemotherapeutic agents have adverse effects on the kidneys and urothelium that can be visualized radiographically, including cystic change, interstitial nephritis, papillary necrosis, urothelial changes, haemorrhagic cystitis, acute tubular necrosis, and infarction. This review focuses on imaging features identifying complications of chemotherapy in the kidneys and collecting system and provides didactic cases to alert referring clinicians
Recommended from our members
Methods for CT Automatic Exposure Control Protocol Translation Between Scanner Platforms
PurposeAn imaging facility with a diverse fleet of CT scanners faces considerable challenges when propagating CT protocols with consistent image quality and patient dose across scanner makes and models. Although some protocol parameters can comfortably remain constant among scanners (eg, tube voltage, gantry rotation time), the automatic exposure control (AEC) parameter, which selects the overall mA level during tube current modulation, is difficult to match among scanners, especially from different CT manufacturers.MethodsObjective methods for converting tube current modulation protocols among CT scanners were developed. Three CT scanners were investigated, a GE LightSpeed 16 scanner, a GE VCT scanner, and a Siemens Definition AS+ scanner. Translation of the AEC parameters such as noise index and quality reference mAs across CT scanners was specifically investigated. A variable-diameter poly(methyl methacrylate) phantom was imaged on the 3 scanners using a range of AEC parameters for each scanner. The phantom consisted of 5 cylindrical sections with diameters of 13, 16, 20, 25, and 32 cm. The protocol translation scheme was based on matching either the volumetric CT dose index or image noise (in Hounsfield units) between two different CT scanners. A series of analytic fit functions, corresponding to different patient sizes (phantom diameters), were developed from the measured CT data. These functions relate the AEC metric of the reference scanner, the GE LightSpeed 16 in this case, to the AEC metric of a secondary scanner.ResultsWhen translating protocols between different models of CT scanners (from the GE LightSpeed 16 reference scanner to the GE VCT system), the translation functions were linear. However, a power-law function was necessary to convert the AEC functions of the GE LightSpeed 16 reference scanner to the Siemens Definition AS+ secondary scanner, because of differences in the AEC functionality designed by these two companies.ConclusionsProtocol translation on the basis of quantitative metrics (volumetric CT dose index or measured image noise) is feasible. Protocol translation has a dependency on patient size, especially between the GE and Siemens systems. Translation schemes that preserve dose levels may not produce identical image quality
Recommended from our members
Unenhanced MDCT in suspected urolithiasis: improved stone detection and density measurements using coronal maximum-intensity-projection images.
ObjectiveThe purpose of this study was to determine whether coronal maximum-intensity-projection (MIP) reformations improve urinary tract stone detection and density measurements compared with routine axial and coronal images.Materials and methodsForty-five consecutive patients who underwent MDCT for suspected urolithiasis were included. Two radiologists independently determined the number of stones on 5-, 3-, and 1.25-mm axial, 5- and 3-mm coronal, and 5-mm coronal MIP images. The reference standard was obtained by consensus review using all six datasets. Stone density was determined for all calculi 4 mm or larger on all datasets.ResultsThere were a total of 115 stones. Reader 1 identified 111 (96.5%), 112 (97.4%), 97 (84.3%), 102 (88.7%), 99 (86.1%), and 85 (73.9%) stones and reader 2 identified 105 (91.3%), 102 (88.7%), 85 (73.9%), 89 (77.4%), 89 (77.4%), and 76 (66.1%) stones on the MIP, 1.25-mm axial, 3-mm axial, 3-mm coronal, 5-mm coronal, and 5-mm axial images, respectively. Both readers identified more stones on the MIP images than on the 3- or 5-mm axial or coronal images (p < 0.0001). The mean difference in stone attenuation compared with the thin axial images was significantly less for the MIP images (44.6 HU) compared with 3-mm axial (235 HU), 3-mm coronal (309 HU), and 5-mm coronal (329.6 HU) or axial images (347.8 HU) (p < 0.0001).ConclusionCoronal MIP reformations allow more accurate identification and density measurements of urinary tract stones compared with routine axial and coronal reformations
JOURNAL CLUB: Quantification of Fetal Dose Reduction if Abdominal CT Is Limited to the Top of the Iliac Crests in Pregnant Patients With Trauma.
ObjectiveThe purposes of this study were to correlate fetal z-axis location within the maternal abdomen on CT with gestational age and estimate fetal dose reduction of a study limited to the abdomen only, with its lower aspect at the top of the iliac crests, compared with full abdominopelvic CT in pregnant trauma patients.Materials and methodsWe performed a study of pregnant patients who underwent CT of the abdomen and pelvis for trauma at a single institution over a 10-year period. The inferior aspect of maternal liver, spleen, gallbladder, pancreas, adrenals, and kidneys was recorded as above or below the iliac crests. The distance from the iliac crest to the top of the fetus or gestational sac was determined. The CT images of the limited and full scanning studies were independently reviewed by two blinded radiologists to identify traumatic injuries. Fetal dose profiles, including both scatter and primary radiation, were computed analytically along the central axis of the patient to estimate fetal dose reduction. Linear regression analysis was performed between gestational age and distance of the fetus to the iliac crests.ResultsThirty-five patients were included (mean age, 26.2 years). Gestational age ranged from 5 to 38 weeks, with 5, 19, and 11 gestations in the first, second, and third trimesters, respectively. All solid organs were above the iliac crests in all patients. In three of six patients, traumatic findings in the pelvis would have been missed with the limited study. There was high correlation between gestational age and distance of the fetus to the iliac crests (R(2) = 0.84). The mean gestational age at which the top of the fetus was at the iliac crest was 17.3 weeks. Using the limited scanning study, fetuses at 5, 20, and 40 weeks of gestation would receive an estimated 4.3%, 26.2%, and 59.9% of the dose, respectively, compared with the dose for the full scanning study.ConclusionIn pregnant patients in our series with a history of trauma, CT of the abdomen only was an effective technique to reduce fetal radiation exposure compared with full abdomen and pelvis CT
JOURNAL CLUB: Quantification of Fetal Dose Reduction if Abdominal CT Is Limited to the Top of the Iliac Crests in Pregnant Patients With Trauma
OBJECTIVE: The purposes of this study were to correlate fetal z-axis location within the maternal abdomen on CT with gestational age and estimate fetal dose reduction of a study limited to the abdomen only, with its lower aspect at the top of the iliac crests, compared with full abdominopelvic CT in pregnant trauma patients. MATERIALS AND METHODS: We performed a study of pregnant patients who underwent CT of the abdomen and pelvis for trauma at a single institution over a 10-year period. The inferior aspect of maternal liver, spleen, gallbladder, pancreas, adrenals, and kidneys was recorded as above or below the iliac crests. The distance from the iliac crest to the top of the fetus or gestational sac was determined. The CT images of the limited and full scanning studies were independently reviewed by two blinded radiologists to identify traumatic injuries. Fetal dose profiles, including both scatter and primary radiation, were computed analytically along the central axis of the patient to estimate fetal dose reduction. Linear regression analysis was performed between gestational age and distance of the fetus to the iliac crests. RESULTS: Thirty-five patients were included (mean age, 26.2 years). Gestational age ranged from 5 to 38 weeks, with 5, 19, and 11 gestations in the first, second, and third trimesters, respectively. All solid organs were above the iliac crests in all patients. In three of six patients, traumatic findings in the pelvis would have been missed with the limited study. There was high correlation between gestational age and distance of the fetus to the iliac crests (R(2) = 0.84). The mean gestational age at which the top of the fetus was at the iliac crest was 17.3 weeks. Using the limited scanning study, fetuses at 5, 20, and 40 weeks of gestation would receive an estimated 4.3%, 26.2%, and 59.9% of the dose, respectively, compared with the dose for the full scanning study. CONCLUSION: In pregnant patients in our series with a history of trauma, CT of the abdomen only was an effective technique to reduce fetal radiation exposure compared with full abdomen and pelvis CT
Recommended from our members
Chemotherapy-related complications in the kidneys and collecting system: an imaging perspective.
UnlabelledNephrotoxicity is a common adverse effect of many chemotherapeutic agents. The agents most commonly associated with chemotherapy-associated nephrotoxicity are methotrexate, semustine, streptozocin, mithramycin, and cisplatin. Certain chemotherapeutic agents have adverse effects on the kidneys and urothelium that can be visualized radiographically, including cystic change, interstitial nephritis, papillary necrosis, urothelial changes, haemorrhagic cystitis, acute tubular necrosis, and infarction. This review focuses on imaging features identifying complications of chemotherapy in the kidneys and collecting system and provides didactic cases to alert referring clinicians.Teaching points• Nephrotoxicity is a common adverse effect of many chemotherapeutic agents. • Chemotherapies have adverse renal and urothelial effects that can be visualized radiographically. • Crizotinib use can result in the development of complex renal cysts
Unenhanced MDCT in Suspected Urolithiasis: Improved Stone Detection and Density Measurements Using Coronal Maximum-Intensity-Projection Images
OBJECTIVE: The purpose of this study was to determine whether coronal maximum-intensity-projection (MIP) reformations improve urinary tract stone detection and density measurements compared with routine axial and coronal images. MATERIALS AND METHODS: Forty-five consecutive patients who underwent MDCT for suspected urolithiasis were included. Two radiologists independently determined the number of stones on 5-, 3-, and 1.25-mm axial, 5- and 3-mm coronal, and 5-mm coronal MIP images. The reference standard was obtained by consensus review using all six datasets. Stone density was determined for all calculi 4 mm or larger on all datasets. RESULTS: There were a total of 115 stones. Reader 1 identified 111 (96.5%), 112 (97.4%), 97 (84.3%), 102 (88.7%), 99 (86.1%), and 85 (73.9%) stones and reader 2 identified 105 (91.3%), 102 (88.7%), 85 (73.9%), 89 (77.4%), 89 (77.4%), and 76 (66.1%) stones on the MIP, 1.25-mm axial, 3-mm axial, 3-mm coronal, 5-mm coronal, and 5-mm axial images, respectively. Both readers identified more stones on the MIP images than on the 3- or 5-mm axial or coronal images (p < 0.0001). The mean difference in stone attenuation compared with the thin axial images was significantly less for the MIP images (44.6 HU) compared with 3-mm axial (235 HU), 3-mm coronal (309 HU), and 5-mm coronal (329.6 HU) or axial images (347.8 HU) (p < 0.0001). CONCLUSION: Coronal MIP reformations allow more accurate identification and density measurements of urinary tract stones compared with routine axial and coronal reformations