    7 T renal MRI: challenges and promises

    Get PDF
    The progression to 7 Tesla (7 T) magnetic resonance imaging (MRI) yields promises of substantial increase in signal-to-noise (SNR) ratio. This increase can be traded off to increase image spatial resolution or to decrease acquisition time. However, renal 7 T MRI remains challenging due to inhomogeneity of the radiofrequency field and due to specific absorption rate (SAR) constraints. A number of studies has been published in the field of renal 7 T imaging. While the focus initially was on anatomic imaging and renal MR angiography, later studies have explored renal functional imaging. Although anatomic imaging remains somewhat limited by inhomogeneous excitation and SAR constraints, functional imaging results are promising. The increased SNR at 7 T has been particularly advantageous for blood oxygen level-dependent and arterial spin labelling MRI, as well as sodium MR imaging, thanks to changes in field-strength-dependent magnetic properties. Here, we provide an overview of the currently available literature on renal 7 T MRI. In addition, we provide a brief overview of challenges and opportunities in renal 7 T MR imaging

    Dual-energy CT of liver metastases in patients with uveal melanoma

    Get PDF
    Objective: To investigate the value of different kVp images of dual-energy CT (DECT) for the detection of liver metastases. Methods: 20 Patients with uveal melanoma were investigated with DECT of the liver. In each patient contrast-enhanced DECT imaging with arterial delay was performed. Number and size of metastases were documented on arterial phase 80-kVp images, virtual 120-kVp images and following angiographic images (DSA) as part of hepatic chemoperfusion. Attenuation of metastases and several anatomic regions, subjective (image noise, image quality) and objective (SNR, CNR) parameters were documented. Results: The mean number of liver metastases detected was significant higher on 80-kVp images than on virtual 120-kVp/DSA images (5.6 ± 2.1 vs. 4.1 ± 1.8/4.3 ± 1.6); (p 20 mm: 56 vs. 42, p 20 mm: 56 vs. 41, p 20 mm were measured statistically equally. Noise, SNR and CNR of 80 kVp images were higher compared to 120 kVp images. Image quality of 120 kVp images was higher compared to 80 kVp images. Conclusion: Low-kVp images of DECT datasets are more sensitive in detecting liver metastases of patients with uveal melanoma than virtual 120 kVp- and DSA images. Keywords: Dual energy CT, Liver, Uveal melanoma, Angiography, Stagin

    Treatment response after radioembolisation in patients with hepatocellular carcinoma—An evaluation with dual energy computed-tomography

    Get PDF
    Purpose: The aim of this prospective study was to examine the diagnostic value of dual-energy CT (DECT) in the assessment of response of HCC after radioembolisation (RE). Material and methods: 40 HCC patients with 82 measurable target lesions were included in this study. At baseline and follow-up examination target lesions were evaluated with (IU), AASLD and Choi measurement criteria. Disease control was defined as the sum of complete response (CR), partial response (PR), progression disease (PD) and stable disease (SD). Results: With Choi and IU more patients were considered than PR and less than PD and SD. According to AASLD more patients were measured as SD and PD than PR. 26/40 patients were classified as PR with IU. In contrast measurements with AASLD in only 8/26 patients were also classified as PR. 6/12 SD patients measured with IU were measured as PD with AASLD. 4/26 patients classified with IU as PR were described as SD with CHOI, 10/14 SD patients measured with CHOI were SD according to IU, the other 4 patients were PR with IU. 2/4 PD patients according to CHOI were SD with IU. Conclusion: More patients by IU were classified as SD versus PD and PR versus SD. We attribute this to the more detailed consideration of the HU differences between the virtual native and contrast-enhanced series generated by DECT. Iodine uptake (IU) in HCC measured and visualized with DECT is a promising imaging method for the assessment of treatment response after radioembolisations. Key points: —dual energy CT of hypervascular tumors such as HCC allows to quantify contrast enhancement without native imaging.—this can be used to evaluate the therapy response after Radioembolization. Keywords: Liver, Radioembolisation, Dual energy, CT stagin

    Determining body height and weight from thoracic and abdominal CT localizers in pediatric and young adult patients using deep learning

    No full text
    Abstract In this retrospective study, we aimed to predict the body height and weight of pediatric patients using CT localizers, which are overview scans performed before the acquisition of the CT. We trained three commonly used networks (EfficientNetV2-S, ResNet-18, and ResNet-34) on a cohort of 1009 and 1111 CT localizers of pediatric patients with recorded body height and weight (between January 2013 and December 2019) and validated them in an additional cohort of 116 and 127 localizers (acquired in 2020). The best-performing model was then tested in an independent cohort of 203 and 225 CT localizers (acquired between January 2021 and March 2023). In addition, a cohort of 1401 and 1590 localizers from younger adults (acquired between January 2013 and December 2013) was added to the training set to determine if it could improve the overall accuracy. The EfficientNetV2-S using the additional adult cohort performed best with a mean absolute error of 5.58 ± 4.26 cm for height and 4.25 ± 4.28 kg for weight. The relative error was 4.12 ± 4.05% for height and 11.28 ± 12.05% for weight. Our study demonstrated that automated estimation of height and weight in pediatric patients from CT localizers can be performed

    Towards fast whole-body PET/MR: Investigation of PET image quality versus reduced PET acquisition times.

    No full text
    PURPOSE:The trend towards faster acquisition protocols in whole-body positron emission tomography/magnetic resonance (PET/MR) arises the question of whether short PET data acquisition protocols in a whole-body multi-station context allow for reduced PET acquisition times while providing adequate PET image quality and accurate quantification parameters. The study goal is to investigate how reducing PET acquisition times affects PET image quality and quantification in whole-body PET/MR in patients with oncologic findings. METHODS:Fifty-one patients with different oncologic findings underwent a clinical whole-body 18F-Fluorodeoxyglucose PET/MR examination. PET data was reconstructed with 4, 3, 2, and 1 min/bed time intervals for each patient to simulate the effect of reduced PET acquisition times. The 4-minute PET reconstructions served as reference standard. All whole-body PET data sets were analyzed regarding image quality, lesion detectability, PET quantification and standardized uptake values. RESULTS:A total of 91 lesions were detected in the 4-minute PET reconstructions. The same number of congruent lesions was also noticed in the 3 and 2 minutes-per-bed (mpb) reconstructed images. A total of 2 lesions in 2 patients was not detected in the 1 minute PET data reconstructions due to poor image quality. Image noise in the blood pool increased from 22.2% (4 mpb) to 42.1% (1 mpb). Signal-to-noise ratio declined with shorter timeframes from 13.1 (4 mpb) to 9.3 (1 mpb). SUVmean and SUVmax showed no significant changes between 4 and 1 mpb reconstructed timeframes. CONCLUSIONS:Reconstruction of PET data with different time intervals has shown that 2 minutes acquisition time per bed position instead of 4 minutes is sufficient to provide accurate lesion detection and adequate image quality in a clinical setting, despite the trends to lower image quality with shorter PET acquisition times. This provides latitude for potential reduction of PET acquisition times in fast PET/MR whole-body examinations

    Atypical bilateral ventilation/perfusion mismatches in an asymptomatic patient suffering from metastatic thyroid cancer

    No full text
    Background!#!Pulmonary embolism is indicated by ventilation/perfusion (V/P) mismatches in ventilation/perfusion scintigraphy. However, other pathologies may also evoke segmental or lobar mismatches. Thus, diagnosis can be difficult in asymptomatic patients with equivocal clinical presentation.!##!Case presentation!#!We present a case of multiple bilateral pulmonary ventilation/perfusion mismatches in a poorly differentiated thyroid cancer patient. Exact diagnosis was difficult, as the patient was asymptomatic and pulmonary embolism is commonly unilateral in tumour patients and not typical for thyroid cancer. External pulmonary artery compression by aortic aneurysm, multiple metastases or additional bronchopulmonary malignancies were considered as differential diagnosis. After unilateral pulmonary and hilar metastasectomy, perfusion normalised on the operated side. Pulmonary perfusion defects due to pulmonary artery compression by hilar metastases were finally diagnosed. Pulmonary embolism was deemed unlikely due to the left-sided post-operative normalisation, persistence of right-sided V/P mismatches, and the lack of clinical symptoms.!##!Conclusion!#!Pulmonary artery compression may mimic pulmonary artery embolism in lung perfusion scintigraphy and should be considered in bronchopulmonary tumour patients with hilar metastases and unilateral ventilation/perfusion mismatches affecting a complete lobe or even lung. Following the presented case, also bilateral segmental and subsegmental mismatches in patients with hilar metastases from non-bronchopulmonary cancer entities should be carefully evaluated

    Measuring the density of iodine depositions: Detecting an invisible residual tumor after conventional transarterial chemoembolization.

    No full text
    PURPOSE:The purpose of this study is to evaluate the use of density measurements in the diagnosis of an underlying residual tumor beyond iodine depositions after Lipiodol-based conventional transarterial chemoembolization (cTACE). METHOD AND MATERIALS:Thirty follow-up CT scans of 20 patients 6-12 weeks after Lipiodol-based cTACE, receiving a digital subtraction angiography at the same time, were analyzed. Reference for the detection of a residual tumor was the angiography, and a visible contrast enhancement was categorized as a residual tumor (n = 16 with residual tumor; n = 14 without residual tumor). The density of the iodine depositions was measured in all containing slices in non-contrast-, arterial- and portal venous-phase CT scans, with a slice thickness of 5.00 mm. The mean density of the iodine deposition during the portal venous phase was subtracted from the mean density of the arterial phase to calculate the density changes (a positive enhancement score represents washout in the portal venous phase). In addition, a quotient relating to the non-contrast measurement was evaluated. RESULTS:Patients with a residual tumor displayed significantly higher enhancement scores in favor of density reduction between the arterial and portal venous phases, compared to patients without a residual tumor (1.41 ± 3.59, n = 14 vs. -13.97 ± 2.88, n = 16; p-value < 0.01). Furthermore, 87.75% of patients with an enhancement score higher than -1.00 (n = 9) had a residual tumor, whereas 100.00% of patients with an enhancement score lower than -20.00 (n = 6) were shown to be tumor-free. The enhancement score quotient resulted in similar findings. CONCLUSION:After cTACE in patients with hepatocellular carcinoma (HCC), the presence of a viable tumor correlated with enhancement scores based on the density measurements of iodine depositions in different phases of the CT scan. Low enhancement scores were associated with completely treated tumors and can aid the decision process to avoid possibly unnecessary angiographies