22 research outputs found

    Impression Cytology of the Lid Wiper Area

    Get PDF
    Muntz, A., van Doorn, K., Subbaraman, L. N., & Jones, L. W. (2016). Impression Cytology of the Lid Wiper Area. Journal of Visualized Experiments, (114). https://doi.org/10.3791/54261Few reports on the cellular anatomy of the lid wiper (LW) area of the inner eyelid exist and only one report makes use of cytological methods. The optimization of a method of collecting, staining and imaging cells from the LW region using impression cytology (IC) is described in this study. Cells are collected from the inner surface of the upper eyelid of human subjects using hydrophilic polytetrafluoroethylene (PTFE) membranes, and stained with cytological dyes to reveal the presence of goblet cells, mucins, cell nuclei and various degrees of pre- and para-keratinization. Immunocytochemical dyes show cell esterase activity and compromised cell membranes by the use of a confocal scanning laser microscope. Up to 100 microscopic digital images are captured for each sample and stitched into a high-resolution, large scale image of the entire IC span. We demonstrate a higher sensitivity of IC than reported before, appropriate for identifying cellular morphologies and metabolic activity in the LW area. To our knowledge, this is the first time this selection of fluorescent dyes was used to image LW IC membranes. This protocol will be effective in future studies to reveal undocumented details of the LW area, such as assessing cellular particularities of contact lens wearers or patients with dry eye or lid wiper epitheliopathy

    Release of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Model

    Get PDF
    Bajgrowicz, M., Phan, C.-M., Subbaraman, L. N., & Jones, L. (2015). Release of Ciprofloxacin and Moxifloxacin From Daily Disposable Contact Lenses From an In Vitro Eye Model. Investigative Opthalmology & Visual Science, 56(4), 2234. https://doi.org/10.1167/iovs.15-16379Purpose.: To analyze the release of two fluoroquinolones, ciprofloxacin and moxifloxacin, from conventional hydrogel (CH) and silicone hydrogel (SH) daily disposable contact lenses (CLs), comparing release from a fixed-volume vial and a novel in vitro eye model. Methods.: Four CH CLs (nelfilcon A, omafilcon A, etafilcon A, ocufilcon B) and three SH CLs (somofilcon A, narafilcon A, delefilcon A) were used. The lenses were incubated in drug solutions for 24 hours. After the incubation period, the lenses were placed in two release conditions: (1) a vial containing 4.8 mL PBS for 24 hours and (2) an in vitro eye model with a flow rate at 4.8 mL over 24 hours. Results.: Release in the vial for both drugs was rapid, reaching a plateau between 15 minutes and 2 hours for all lenses. In contrast, under physiological flow conditions, a constant and slow release was observed over 24 hours. The amounts of ciprofloxacin released from the lenses ranged between 49.6 ± 0.7 and 62.8 ± 0.3 μg per lens in the vial, and between 35.0 ± 7.0 and 109.0 ± 5.0 μg per lens in the eye model. Moxifloxacin release ranged from 24.0 ± 4.0 to 226.0 ± 2.0 μg per lens for the vial, and between 13.0 ± 2.0 and 151.0 ± 10.0 μg per lens in the eye model. In both systems and for both drugs, HEMA-based CLs released more drugs than other materials. Conclusions.: The parameters of the release system, in particular the volume and flow rate, have a significant influence on measured release profiles. Under physiological flow, release profiles are significantly slower and constant when compared with release in a vial

    Release of Moxifloxacin from Contact Lenses Using an In Vitro Eye Model: Impact of Artificial Tear Fluid Composition and Mechanical Rubbing

    Get PDF
    Phan, C.-M., Bajgrowicz-Cieslak, M., Subbaraman, L. N., & Jones, L. (2016). Release of Moxifloxacin from Contact Lenses Using an In Vitro Eye Model: Impact of Artificial Tear Fluid Composition and Mechanical Rubbing. Translational Vision Science & Technology, 5(6), 3. https://doi.org/10.1167/tvst.5.6.3Purpose: The aim of this study was to evaluate and compare the release of moxifloxacin from a variety of daily disposable (DD) contact lenses (CLs) under various conditions using a novel in vitro eye model. Methods: Four commercially available DD conventional hydrogel (CH) CLs (nelfilcon A, omafilcon A, etafilcon A, and ocufilcon B) and three silicone hydrogel (SH) CLs (somofilcon A, narafilcon A, and delefilcon A) were evaluated. These lenses were incubated in moxifloxacin for 24 hours. The release of the drug was measured using a novel in vitro model in three experimental conditions: (1) phosphate buffered saline (PBS); (2) artificial tear solution (ATS) containing a variety of proteins and lipids; and (3) ATS with mechanical rubbing produced by the device. Results: Overall, CH CLs had a higher drug release than SH CLs (P < 0.05) under all conditions. Typically, a higher drug release was observed in PBS than ATS (P < 0.05). For CH, drug release was found to be higher in ATS with rubbing than PBS or ATS (P < 0.05). For most lens types, ATS with rubbing produced higher drug release than ATS alone (P < 0.05). Generally, the release kinetics for all conditions were sustained over the 24-hour testing period, and no burst release was observed (P < 0.05). Conclusions: Moxifloxacin release from a CL into ATS is lower when compared to release into PBS. When mechanical rubbing is introduced, the amount of drugs released is increased. Translational Relevance: Results suggest that sophisticated in vitro models are necessary to adequately model on-eye drug release from CL materials

    Insights to Using Contact Lenses for Drug Delivery

    Get PDF
    Phan, C.-M. (2013). Insights to Using Contact Lenses for Drug Delivery. Clinical & Experimental Pharmacology, 04(01). https://doi.org/10.4172/2161-1459.1000145There has been considerable interest in the potential application of contact lenses for ocular drug delivery. This short communication provides an overview of the challenges faced by delivering drugs using contact lenses, highlights the solutions to limitations that have already been achieved, and describes the barriers that remain before commercial application can be realized.NSERC 20/20 Network for the Development of Advanced Ophthalmic Material

    Development of an In Vitro Ocular Platform to Test Contact Lenses

    Get PDF
    The definitive version of Development of an in Vitro Ocular Platform to Test Contact Lenses was published by Emerald www.emeraldinsight.com in Journal of Visualized Experiments, (110) (2016) https://doi.org/10.3791/53907Currently, in vitro evaluations of contact lenses (CLs) for drug delivery are typically performed in large volume vials,1-6 which fail to mimic physiological tear volumes.7 The traditional model also lacks the natural tear flow component and the blinking reflex, both of which are defining factors of the ocular environment. The development of a novel model is described in this study, which consists of a unique 2-piece design, eyeball and eyelid piece, capable of mimicking physiological tear volume. The models are created from 3-D printed molds (Polytetrafluoroethylene or Teflon molds), which can be used to generate eye models from various polymers, such as polydimethylsiloxane (PDMS) and agar. Further modifications to the eye pieces, such as the integration of an explanted human or animal cornea or human corneal construct, will permit for more complex in vitro ocular studies. A commercial microfluidic syringe pump is integrated with the platform to emulate physiological tear secretion. Air exposure and mechanical wear are achieved using two mechanical actuators, of which one moves the eyelid piece laterally, and the other moves the eyeballeyepiece circularly. The model has been used to evaluate CLs for drug delivery and deposition of tear components on CLs

    BCLA CLEAR Presbyopia: Management with contact lenses and spectacles

    Get PDF
    This paper seeks to outline the history, market situation, clinical management and product performance related to the correction of presbyopia with both contact lenses and spectacles. The history of the development of various optical forms of presbyopic correction are reviewed, and an overview is presented of the current market status of contact lenses and spectacles. Clinical considerations in the fitting and aftercare of presbyopic contact lens and spectacle lens wearers are presented, with general recommendations for best practice. Current options for contact lens correction of presbyopia include soft simultaneous, rigid translating and rigid simultaneous designs, in addition to monovision. Spectacle options include single vision lenses, bifocal lenses and a range of progressive addition lenses. The comparative performance of both contact lens and spectacle lens options is presented. With a significant proportion of the global population now being presbyopic, this overview is particularly timely and is designed to act as a guide for researchers, industry and eyecare practitioners alike

    Lysozyme Deposition Studies on Silicone Hydrogel Contact Lens Materials

    No full text
    I hereby declare that I am the sole author of this thesis. This is a true copy of the thesis, including any required final revisions, as accepted by my examiners. I understand that my thesis may be made electronically available to the public. ii Over 60 proteins have been detected in the tear film and among these lysozyme has attracted the greatest attention. Several techniques for elucidating the identity, quantity and conformation of lysozyme deposited on soft contact lenses have been developed. Lysozyme also deposits on the newly introduced silicone hydrogel (SH) lens materials, but in extremely low levels compared to conventional hydrogel lenses. Hence, a major analytical complication with the study of the SH contact lens materials relates to the minute quantity of deposited lysozyme. The first project of this thesis involved the development of a method whereby lysozyme mass extracted from SH lens materials would be preserved over time and would be compatible with an optimized Western blotting procedure. This methodological development wa

    Tear exchange and contact lenses: A review

    Get PDF
    Tear exchange beneath a contact lens facilitates ongoing fluid replenishment between the ocular surface and the lens. This exchange is considerably lower during the wear of soft lenses compared with rigid lenses. As a result, the accumulation of tear film debris and metabolic by-products between the cornea and a soft contact lens increases, potentially leading to complications. Lens design innovations have been proposed, but no substantial improvement in soft lens tear exchange has been reported. Researchers have determined post-lens tear exchange using several methods, notably fluorophotometry. However, due to technological limitations, little remains known about tear hydrodynamics around the lens and, to-date, true tear exchange with contact lenses has not been shown. Further knowledge regarding tear exchange could be vital in aiding better contact lens design, with the prospect of alleviating certain adverse ocular responses. This article reviews the literature to-date on the significance, implications and measurement of tear exchange with contact lenses
    corecore