298 research outputs found

    Genetic analysis of Eclosion hormone action during Drosophila larval ecdysis

    Get PDF
    Insect growth is punctuated by molts, during which the animal produces a new exoskeleton. The molt culminates with ecdysis, an ordered sequence of behaviors that causes the old cuticle to be shed. This sequence is activated by Ecdysis Triggering Hormone (ETH), which acts on the CNS to activate neurons that produce neuropeptides implicated in ecdysis, including Eclosion hormone (EH), Crustacean Cardioactive Peptide (CCAP), and bursicon. Despite over 40 years of research on ecdysis, our understanding of the precise roles of these neurohormones remains rudimentary. Of particular interest is EH, whose role beyond the well-accepted action of massively upregulating ETH release has remained elusive. We report on the isolation of an eh null mutant in Drosophila, and use it to investigate the role of EH in larval ecdysis. We found that null mutant animals invariably died at around the time of ecdysis, revealing an essential role in its control. Unexpectedly, however, they failed to express the preparatory behavior of pre-ecdysis while directly expressing the motor program of ecdysis. In addition, although ETH release could not be detected in these animals, the lack of pre-ecdysis could not be rescued by injections of ETH, suggesting that EH is required within the CNS for ETH to trigger the normal ecdysial sequence. Using a genetically-encoded calcium probe we show that EH configures the response of the CNS to ETH. These findings show that EH plays an essential role in the Drosophila CNS in the control of ecdysis, in addition to its known role in the periphery of triggering ETH release.</jats:p

    What does it take to make integrated care work? A ‘cookbook’ for large-scale deployment of coordinated care and telehealth

    Get PDF
    The Advancing Care Coordination & Telehealth Deployment (ACT) Programme is the first to explore the organisational and structural processes needed to successfully implement care coordination and telehealth (CC&TH) services on a large scale. A number of insights and conclusions were identified by the ACT programme. These will prove useful and valuable in supporting the large-scale deployment of CC&TH. Targeted at populations of chronic patients and elderly people, these insights and conclusions are a useful benchmark for implementing and exchanging best practices across the EU. Examples are: Perceptions between managers, frontline staff and patients do not always match; Organisational structure does influence the views and experiences of patients: a dedicated contact person is considered both important and helpful; Successful patient adherence happens when staff are engaged; There is a willingness by patients to participate in healthcare programmes; Patients overestimate their level of knowledge and adherence behaviour; The responsibility for adherence must be shared between patients and health care providers; Awareness of the adherence concept is an important factor for adherence promotion; The ability to track the use of resources is a useful feature of a stratification strategy, however, current regional case finding tools are difficult to benchmark and evaluate; Data availability and homogeneity are the biggest challenges when evaluating the performance of the programmes

    SIC-8000 versus hetastarch as a submucosal injection fluid for endoscopic mucosal resection: a randomized controlled trial

    Get PDF
    Background and Aims Viscous solutions provide a superior submucosal cushion for endoscopic mucosal resection (EMR). SIC-8000 (Eleview, Aries Pharmaceuticals, La Jolla, Calif) is a commercially available FDA approved solution but hetastarch is also advocated. We performed a randomized trial comparing SIC-8000 to hetastarch as submucosal injection agents for colorectal EMR. Methods This was a single-center double-blinded randomized controlled trial performed at a tertiary referral center. Patients were referred to our center with flat or sessile lesions measuring ≥15 mm in size. The primary outcome measures were the Sydney Resection Quotient (SRQ) and the rate of en bloc resections. Secondary outcomes were total volume needed for a sufficient lift, number of resected pieces, and adverse events. Results There were 158 patients with 159 adenomas (84 SIC-8000 and 75 hetastarch) and 57 serrated lesions (30 SIC-8000 and 27 hetastarch). SRQ was significantly better in the SIC-8000 group compared with hetastarch group (9.3 vs 8.1, p=0.001). There was no difference in the proportion of lesions with en bloc resections. The total volume of injectate was significantly lower with SIC-8000 (14.8 mL vs 20.6 mL, p=0.038) Conclusions SIC-8000 is superior to hetastarch for use during EMR in terms of SRQ and total volume needed, although the absolute differences were small

    A comparison of 2 distal attachment mucosal exposure devices: a noninferiority randomized controlled trial

    Get PDF
    Background and Aims Endocuff and Endocuff Vision are effective mucosal exposure devices for improving polyp detection during colonoscopy. AmplifEYE is a knock-off device that appears similar to the Endocuff devices but has received minimal clinical testing. Methods We performed a randomized controlled clinical trial using a noninferiority design to compare Endocuff Vision with AmplifEYE. Results The primary endpoint of adenomas per colonoscopy was similar in AmplifEYE at 1.63 (2.83) versus 1.51 (2.29) with Endocuff Vision; p=0.535. The 95% lower confidence limit was 0.88 for ratio of means, establishing noninferiority of AmplifEYE (p=0.008). There was no difference between the arms in mean insertion time, and mean inspection time (withdrawal time minus polypectomy time and time for washing and suctioning) was shorter with AmplifEYE (6.8 minutes vs 6.9 minutes, p=0.042). Conclusions AmplifEYE is noninferior to Endocuff Vision for adenoma detection. The decision of which device to use can be based on cost. Additional comparisons of AmplifEYE to Endocuff by other investigators are warranted

    Impact of a ring fitted cap on insertion time and adenoma detection: a randomized controlled trial

    Get PDF
    Background and Aims: Devices for flattening colon folds can improve polyp detection at colonoscopy. However, there are few data on the endoscopic ring fitted cap (EndoRings, EndoAid, Caesarea, Israel). We sought to compare adenoma detection with EndoRings with that of standard high-definition colonoscopy. Methods: A single-center randomized controlled trial of 562 patients (284 randomized to EndoRings and 278 to standard colonoscopy) at 2 outpatient endoscopy units in the Indiana University Hospital system. Adenoma detection was the primary outcome measured as adenoma detection rate (ADR) and adenomas per colonoscopy (APC). We also compared sessile serrated polyp detection rate (SSPDR), insertion times, withdrawal times, and ease of passage through the sigmoid colon. Results: EndoRings was superior to standard colonoscopy in terms of APC (1.46 vs 1.06, p=0.025) but there were no statistically significant differences in ADR or SSPDR. Mean withdrawal time (in patients with no polyps) was shorter and insertion time (all patients) was longer in the EndoRings arm by 1.8 minutes and 0.75 minutes, respectively. One provider had significantly higher detection with EndoRings and contributed substantially to the overall results. Conclusions: EndoRings can increase adenoma detection without significant increase in procedure time, but the effect varies between operators. EndoRings slows colonoscope insertion

    Impact of water filling on terminal ileum intubation with a distal-tip mucosal exposure device

    Get PDF
    Background and Aims Endocuff improves detection at colonoscopy but seems to impede terminal ileal (TI) intubation. We assessed the impact of Endocuff Vision (EV) on TI intubation using adult or pediatric colonoscopes and evaluated whether filling the cecum with gas versus water affected the impact of EV on TI intubation. Methods Using a prospectively recorded quality control database, we explored the impact of EV on TI intubation in ≤1 minute. We used adult and pediatric colonoscopes and tested the effect of filling the cecum with gas versus water. If the initial attempt failed, then the alternative (water vs gas) was tried as a rescue method. Results TI intubation in ≤1 minute occurred in 91% of colonoscopies without EV versus 65% with EV, but the use of the pediatric colonoscope with EV had a higher success rate for TI intubation in ≤1 minute compared with the adult colonoscope with EV (73% vs 57%, P = .043). TI intubation in ≤1 minute was more successful with EV when the cecum was filled with water rather than gas (74% vs 56%, P = .019), but the benefit of water filling was limited to the adult colonoscope with EV. When EV was in place, water filling was more successful as a rescue method of TI intubation (58% vs 21%, P = .011). Conclusions EV adversely affects TI intubation, particularly for adult colonoscopes. Water filling of the cecum mitigates the impact of EV on TI intubation with adult colonoscopes

    Ancient Migratory Events in the Middle East: New Clues from the Y-Chromosome Variation of Modern Iranians

    Get PDF
    Knowledge of high resolution Y-chromosome haplogroup diversification within Iran provides important geographic context regarding the spread and compartmentalization of male lineages in the Middle East and southwestern Asia. At present, the Iranian population is characterized by an extraordinary mix of different ethnic groups speaking a variety of Indo-Iranian, Semitic and Turkic languages. Despite these features, only few studies have investigated the multiethnic components of the Iranian gene pool. In this survey 938 Iranian male DNAs belonging to 15 ethnic groups from 14 Iranian provinces were analyzed for 84 Y-chromosome biallelic markers and 10 STRs. The results show an autochthonous but non-homogeneous ancient background mainly composed by J2a sub-clades with different external contributions. The phylogeography of the main haplogroups allowed identifying post-glacial and Neolithic expansions toward western Eurasia but also recent movements towards the Iranian region from western Eurasia (R1b-L23), Central Asia (Q-M25), Asia Minor (J2a-M92) and southern Mesopotamia (J1-Page08). In spite of the presence of important geographic barriers (Zagros and Alborz mountain ranges, and the Dasht-e Kavir and Dash-e Lut deserts) which may have limited gene flow, AMOVA analysis revealed that language, in addition to geography, has played an important role in shaping the nowadays Iranian gene pool. Overall, this study provides a portrait of the Y-chromosomal variation in Iran, useful for depicting a more comprehensive history of the peoples of this area as well as for reconstructing ancient migration routes. In addition, our results evidence the important role of the Iranian plateau as source and recipient of gene flow between culturally and genetically distinct population
    • …
    corecore