28 research outputs found

    Mapping The In-Plane Electric Field Inside Irradiated Diodes

    Get PDF
    A significant aspect of the Phase-II Upgrade of the ATLAS detector is the replacement of the current Inner Detector with the ATLAS Inner Tracker (ITk). The ATLAS ITk is an all-silicon detector consisting of a pixel tracker and a strip tracker. Sensors for the ITk strip tracker have been developed to withstand the high radiation environment in the ATLAS detector after the High Luminosity Upgrade of the Large Hadron Collider at CERN, which will significantly increase the rate of particle collisions and resulting particle tracks. During their operation in the ATLAS detector, sensors for the ITk strip tracker are expected to accumulate fluences up to 1.61015neq/cm2 (including a safety factor of 1.5), which will significantly affect their performance. One characteristic of interest for highly irradiated sensors is the shape and homogeneity of the electric field inside its active area. For the results presented here, diodes with edge structures similar to full size ATLAS sensors were irradiated up to fluences comparable to those in the ATLAS ITk strip tracker and their electric fields mapped using a micro-focused X-ray beam (beam diameter 23m2). This study shows the extension and shape of the electric field inside highly irradiated diodes over a range of applied bias voltages. Additionally, measurements of the outline of the depleted sensor areas allow a comparison of the measured leakage current for different fluences with expectations for the corresponding active areas

    Radiation Campaign of HPK Prototype LGAD sensors for the High-Granularity Timing Detector (HGTD)

    Full text link
    We report on the results of a radiation campaign with neutrons and protons of Low Gain Avalanche Detectors (LGAD) produced by Hamamatsu (HPK) as prototypes for the High-Granularity Timing Detector (HGTD) in ATLAS. Sensors with an active thickness of 50~μ\mum were irradiated in steps of roughly 2×\times up to a fluence of 3×1015 neqcm23\times10^{15}~\mathrm{n_{eq}cm^{-2}}. As a function of the fluence, the collected charge and time resolution of the irradiated sensors will be reported for operation at 30-30^{\circ}

    Beam test results of a 16 ps timing system based on ultra-fast silicon detectors

    Full text link
    In this paper we report on the timing resolution of the first production of 50 micro-meter thick Ultra-Fast Silicon Detectors (UFSD) as obtained in a beam test with pions of 180 GeV/c momentum. UFSD are based on the Low-Gain Avalanche Detectors (LGAD) design, employing n-on-p silicon sensors with internal charge multiplication due to the presence of a thin, low-resistivity diffusion layer below the junction. The UFSD used in this test belongs to the first production of thin (50 {\mu}m) sensors, with an pad area of 1.4 mm2. The gain was measured to vary between 5 and 70 depending on the bias voltage. The experimental setup included three UFSD and a fast trigger consisting of a quartz bar readout by a SiPM. The timing resolution, determined comparing the time of arrival of the particle in one or more UFSD and the trigger counter, for single UFSD was measured to be 35 ps for a bias voltage of 200 V, and 26 ps for a bias voltage of 240 V, and for the combination of 3 UFSD to be 20 ps for a bias voltage of 200 V, and 15 ps for a bias voltage of 240 V.Comment: 7 pages, 8 figures, 1 table, Subm. to NIM

    Experimental Study of Acceptor Removal in UFSD

    Full text link
    The performance of the Ultra-Fast Silicon Detectors (UFSD) after irradiation with neutrons and protons is compromised by the removal of acceptors in the thin layer below the junction responsible for the gain. This effect is tested both with C-V measurements of the doping concentration and with measurements of charge collection using charged particles. We find a perfect linear correlation between the bias voltage to deplete the gain layer determined with C-V and the bias voltage to collect a defined charge, measured with charge collection. An example for the usefulness of this correlation is presented.Comment: 14 pages, 10 Figs., Sumitted to HSTD12 Hiroshima 201

    Measuring the border of the active area on silicon strip sensors

    No full text
    Silicon strip sensors for the ATLAS Inner Tracker (ITk) have been designed to provide reliable particle detection in the high-radiation environment of the High-Luminosity Large Hadron Collider. One important design criterion for their development is the minimization of inactive sensor areas, which affect the hermiticity of particle detection inside the detector. In previous measurements of ATLAS silicon strip sensors, the charge-collecting area of individual strip implants has been mapped and found to agree with the sensor strip pitch and strip length. For strip implants next to the sensor bias ring, the extent of their charge-collecting area towards the inactive sensor area was previously unknown, which limited the accuracy of both overall detector hermiticity estimates and the position resolution for particle detection at the sensor edge. Therefore, measurements were conducted to map the area of charge collection for sensor strips at the edge of the active sensor area using a micro-focused X-ray beam. This publication presents measurements showing the extent of charge collection in the edge strips of silicon strip sensors for two generations of ATLAS ITk strip sensor modules. The measurements confirmed that charge deposited in a strip implant that is neither connected nor grounded leads to capacitive coupling to the adjacent strip, where it is indistinguishable from a hit in that strip
    corecore