165 research outputs found

    The effect of aging on nasal mucociliary clearance, beat frequency and ultrastructure of respiratory cilia

    Get PDF
    published_or_final_versio

    Use and limitations of malaria rapid diagnostic testing by community health workers in war-torn Democratic Republic of Congo

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Accurate and practical malaria diagnostics, such as immunochromatographic rapid diagnostic tests (RDTs), have the potential to avert unnecessary treatments and save lives. Volunteer community health workers (CHWs) represent a potentially valuable human resource for expanding this technology to where it is most needed, remote rural communities in sub-Saharan Africa with limited health facilities and personnel. This study reports on a training programme for CHWs to incorporate RDTs into their management strategy for febrile children in the Democratic Republic of Congo, a tropical African setting ravaged by human conflict.</p> <p>Methods</p> <p>Prospective cohort study, satisfaction questionnaire and decision analysis.</p> <p>Results</p> <p>Twelve CHWs were trained to safely and accurately perform and interpret RDTs, then successfully implemented rapid diagnostic testing in their remote community in a cohort of 357 febrile children. CHWs were uniformly positive in evaluating RDTs for their utility and ease of use. However, high malaria prevalence in this cohort (93% by RDTs, 88% by light microscopy) limited the cost-effectiveness of RDTs compared to presumptive treatment of all febrile children, as evidenced by findings from a simplified decision analysis.</p> <p>Conclusions</p> <p>CHWs can safely and effectively use RDTs in their management of febrile children; however, cost-effectiveness of RDTs is limited in zones of high malaria prevalence.</p

    Finite volume analysis of temperature effects induced by active MRI implants with cylindrical symmetry: 1. Properly working devices

    Get PDF
    BACKGROUND: Active Magnetic Resonance Imaging implants are constructed as resonators tuned to the Larmor frequency of a magnetic resonance system with a specific field strength. The resonating circuit may be embedded into or added to the normal metallic implant structure. The resonators build inductively coupled wireless transmit and receive coils and can amplify the signal, normally decreased by eddy currents, inside metallic structures without affecting the rest of the spin ensemble. During magnetic resonance imaging the resonators generate heat, which is additional to the usual one described by the specific absorption rate. This induces temperature increases of the tissue around the circuit paths and inside the lumen of an active implant and may negatively influence patient safety. METHODS: This investigation provides an overview of the supplementary power absorbed by active implants with a cylindrical geometry, corresponding to vessel implants such as stents, stent grafts or vena cava filters. The knowledge of the overall absorbed power is used in a finite volume analysis to estimate temperature maps around different implant structures inside homogeneous tissue under worst-case assumptions. The "worst-case scenario" assumes thermal heat conduction without blood perfusion inside the tissue around the implant and mostly without any cooling due to blood flow inside vessels. RESULTS: The additional power loss of a resonator is proportional to the volume and the quality factor, as well as the field strength of the MRI system and the specific absorption rate of the applied sequence. For properly working devices the finite volume analysis showed only tolerable heating during MRI investigations in most cases. Only resonators transforming a few hundred mW into heat may reach temperature increases over 5 K. This requires resonators with volumes of several ten cubic centimeters, short inductor circuit paths with only a few 10 cm and a quality factor above ten. Using MR sequences, for which the MRI system manufacturer declares the highest specific absorption rate of 4 W/kg, vascular implants with a realistic construction, size and quality factor do not show temperature increases over a critical value of 5 K. CONCLUSION: The results show dangerous heating for the assumed "worst-case scenario" only for constructions not acceptable for vascular implants. Realistic devices are safe with respect to temperature increases. However, this investigation discusses only properly working devices. Ruptures or partial ruptures of the wires carrying the electric current of the resonance circuits or other defects can set up a power source inside an extremely small volume. The temperature maps around such possible "hot spots" should be analyzed in an additional investigation

    2019 international consensus on cardiopulmonary resuscitation and emergency cardiovascular care science with treatment recommendations : summary from the basic life support; advanced life support; pediatric life support; neonatal life support; education, implementation, and teams; and first aid task forces

    No full text
    The International Liaison Committee on Resuscitation has initiated a continuous review of new, peer-reviewed, published cardiopulmonary resuscitation science. This is the third annual summary of the International Liaison Committee on Resuscitation International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. It addresses the most recent published resuscitation evidence reviewed by International Liaison Committee on Resuscitation Task Force science experts. This summary addresses the role of cardiac arrest centers and dispatcher-assisted cardiopulmonary resuscitation, the role of extracorporeal cardiopulmonary resuscitation in adults and children, vasopressors in adults, advanced airway interventions in adults and children, targeted temperature management in children after cardiac arrest, initial oxygen concentration during resuscitation of newborns, and interventions for presyncope by first aid providers. Members from 6 International Liaison Committee on Resuscitation task forces have assessed, discussed, and debated the certainty of the evidence on the basis of the Grading of Recommendations, Assessment, Development, and Evaluation criteria, and their statements include consensus treatment recommendations. Insights into the deliberations of the task forces are provided in the Justification and Evidence to Decision Framework Highlights sections. The task forces also listed priority knowledge gaps for further research

    Cost of increasing access to artemisinin combination therapy: the Cambodian experience

    Get PDF
    BACKGROUND: Malaria-endemic countries are switching antimalarial drug policy from cheap ineffective monotherapies to artemisinin combination therapies (ACTs) for the treatment of Plasmodium falciparum malaria and the global community are considering setting up a global subsidy to fund their purchase. However, in order to ensure that ACTs are correctly used and are accessible to the poor and remote communities who need them, specific interventions will be necessary and the additional costs need to be considered. METHODS: This paper presents an incremental cost analysis of some of these interventions in Cambodia, the first country to change national antimalarial drug policy to an ACT of artesunate and mefloquine. These costs include the cost of rapid diagnostic tests (RDTs), the cost of blister-packaging the drugs locally and the costs of increasing access to diagnosis and treatment to remote communities through malaria outreach teams (MOTs) and Village Malaria Workers (VMW). RESULTS: At optimum productive capacity, the cost of blister-packaging cost under 0.20perpackagebutinrealitywassignificantlymorethanthisbecauseofthelowrateofproduction.Theannualfixedcost(exclusiveofRDTsanddrugs)percapitaoftheMOTandVMWschemeswas0.20 per package but in reality was significantly more than this because of the low rate of production. The annual fixed cost (exclusive of RDTs and drugs) per capita of the MOT and VMW schemes was 0.44 and 0.69respectively.HoweverbecausetheVMWschemeachievedahigherrateofcoveragethantheMOTscheme,thecostperpatienttreatedwassubstantiallylowerat0.69 respectively. However because the VMW scheme achieved a higher rate of coverage than the MOT scheme, the cost per patient treated was substantially lower at 5.14 compared to 12.74perfalciparummalariapatienttreated.TheannualcostinclusiveoftheRDTsanddrugswas12.74 per falciparum malaria patient treated. The annual cost inclusive of the RDTs and drugs was 19.31 for the MOT scheme and $11.28 for the VMW scheme given similar RDT positivity rates of around 22% and good provider compliance to test results. CONCLUSION: In addition to the cost of ACTs themselves, substantial additional investments are required in order to ensure that they reach the targeted population via appropriate delivery systems and to ensure that they are used appropriately. In addition, differences in local conditions, in particular the prevalence of malaria and the pre-existing infrastructure, need to be considered in choosing appropriate diagnostic and delivery strategies

    Mechanical versus manual chest compressions in the treatment of in-hospital cardiac arrest patients in a non-shockable rhythm : a randomised controlled feasibility trial (COMPRESS-RCT)

    Get PDF
    Background Mechanical chest compression devices consistently deliver high-quality chest compressions. Small very low-quality studies suggest mechanical devices may be effective as an alternative to manual chest compressions in the treatment of adult in-hospital cardiac arrest patients. The aim of this feasibility trial is to assess the feasibility of conducting an effectiveness trial in this patient population. Methods COMPRESS-RCT is a multi-centre parallel group feasibility randomised controlled trial, designed to assess the feasibility of undertaking an effectiveness to compare the effect of mechanical chest compressions with manual chest compressions on 30-day survival following in-hospital cardiac arrest. Over approximately two years, 330 adult patients who sustain an in-hospital cardiac arrest and are in a non-shockable rhythm will be randomised in a 3:1 ratio to receive ongoing treatment with a mechanical chest compression device (LUCAS 2/3, Jolife AB/Stryker, Lund, Sweden) or continued manual chest compressions. It is intended that recruitment will occur on a 24/7 basis by the clinical cardiac arrest team. The primary study outcome is the proportion of eligible participants randomised in the study during site operational recruitment hours. Participants will be enrolled using a model of deferred consent, with consent for follow-up sought from patients or their consultee in those that survive the cardiac arrest event. The trial will have an embedded qualitative study, in which we will conduct semi-structured interviews with hospital staff to explore facilitators and barriers to study recruitment. Discussion The findings of COMPRESS-RCT will provide important information about the deliverability of an effectiveness trial to evaluate the effect on 30-day mortality of routine use of mechanical chest compression devices in adult in-hospital cardiac arrest patients

    Differential Proteome Analysis of Bone Marrow Mesenchymal Stem Cells from Adolescent Idiopathic Scoliosis Patients

    Get PDF
    Adolescent idiopathic scoliosis (AIS) is a complex three-dimensional deformity of the spine. The cause and pathogenesis of scoliosis and the accompanying generalized osteopenia remain unclear despite decades of extensive research. In this study, we utilized two-dimensional fluorescence difference gel electrophoresis (2D-DIGE) coupled with mass spectrometry (MS) to analyze the differential proteome of bone marrow mesenchymal stem cells (BM-MSCs) from AIS patients. In total, 41 significantly altered protein spots were detected, of which 34 spots were identified by MALDI-TOF/TOF analysis and found to represent 25 distinct gene products. Among these proteins, five related to bone growth and development, including pyruvate kinase M2, annexin A2, heat shock 27 kDa protein, Ξ³-actin, and Ξ²-actin, were found to be dysregulated and therefore selected for further validation by Western blot analysis. At the protein level, our results supported the previous hypothesis that decreased osteogenic differentiation ability of MSCs is one of the mechanisms leading to osteopenia in AIS. In summary, we analyzed the differential BM-MSCs proteome of AIS patients for the first time, which may help to elucidate the underlying molecular mechanisms of bone loss in AIS and also increase understanding of the etiology and pathogenesis of AIS

    In vivo fluorescence imaging of the transport of charged chlorine6 conjugates in a rat orthotopic prostate tumour

    Get PDF
    Polymeric drug conjugates are used in cancer therapy and, varying their molecular size and charge, will affect their in vivo transport and extravasation in tumours. Partitioning between tumour vasculature and tumour tissue will be of particular significance in the case of photosensitizer conjugates used in photodynamic therapy, where this partitioning can lead to different therapeutic effects. Poly-l-lysine chlorine6 conjugates (derived from polymers of averageMr 5000 and 25 000) were prepared both in a cationic state and by poly-succinylation in an anionic state. A fluorescence scanning laser microscope was used to follow the pharmacokinetics of these conjugates in vivo in an orthotopic rat prostate cancer model obtained with MatLyLu cells. Fluorescence was excited with the 454–528 nm group of lines of an argon laser and a 570 nm long pass filter used to isolate the emission. Results showed that the conjugates initially bound to the walls of the vasculature, before extravasating into the tissue, and eventually increasing in fluorescence. The anionic conjugates produced tissue fluorescence faster than the cationic ones, and surprisingly, the largerMr conjugates produced tissue fluorescence faster than the smaller ones with the same charge. These results are consistent with differences in aggregation state between conjugates. Β© 1999 Cancer Research Campaig
    • …
    corecore