1,204 research outputs found

    Developing a platform of environmental omics for the green-lipped mussel Perna viridis

    Get PDF
    Session Track: Aquatic and terrestrial ecotoxicologyOral presentationConference Theme: Science across bridges, borders and boundariesThe green-lipped mussel Perna viridis is an important marine biomonitor species in pollution monitoring and ecotoxicological studies in Asia-Pacific region, and considered as a subtropical equivalent biomonitor of the temperate Mytilus species. However, the genomic information of P. viridis is still largely unexplored when compared with Mytilus species. This study aimed to establish a transcriptomic profile of P. viridis using the next generation sequencing technology and provide a good representative set of genomic information for elucidation of toxic mechanisms upon pollution stresses and identification of a suite of suitable biomarkers for monitoring marine pollution and environmental stresses. To obtain a wide spectrum of environmental-associated transcripts, adult mussels (4-5 cm shell length) were collected from different locations in Hong Kong and from those after 24-hour exposures to various challenges of physical stresses and chemical pollutants, so as to cover a wide range of stress-associated transcription patterns for future environmental studies. Two males and females from each location and from each treatment were chosen for obtaining the three target tissues (i.e., hepatopancreas, gill and adductor muscle). For each sex and each tissue type, a total RNA sample was extracted from pooled tissues from the field and laboratory treated mussels. The RNA sample was subjected to cDNA library construction, followed by the RNA-sequencing using a Solexa GAIIx (Illumina). Including the splicing variants, a de novo assembly of a total length of 295,064,579 base-pair (bp) contig was obtained, with 233,257 contigs assembled of an average size of 1264 bp. The 192,879 non-redundant assembled transcripts were blasted against the NCBI nr database and three molluscan EST databases, and resulted in 44,713 transcripts with at least a blast hit, and having a top match with the sequences from the Pacific oyster, Crassostrea gigas (27,651 transcripts). A total of 5,131 transcripts were assigned with KEGG annotation involving in 329 pathways. Based on multivariate statistical analysis, expression patterns of genes from stress associated responses and detoxification were strongly tissue-specific but the differences between genders were little. The anticipated genomic database generated from this study will further strengthen the role of P. viridis as a universal marine biomonitor in the Asia-Pacific region.published_or_final_versio

    Uncertainty quantification in non-rigid image registration via stochastic gradient Markov chain Monte Carlo

    Get PDF
    We develop a new Bayesian model for non-rigid registration of three-dimensional medical images, with a focus on uncertainty quantification. Probabilistic registration of large images with calibrated uncertainty estimates is difficult for both computational and modelling reasons. To address the computational issues, we explore connections between the Markov chain Monte Carlo by backpropagation and the variational inference by backpropagation frameworks, in order to efficiently draw samples from the posterior distribution of transformation parameters. To address the modelling issues, we formulate a Bayesian model for image registration that overcomes the existing barriers when using a dense, high-dimensional, and diffeomorphic transformation parametrisation. This results in improved calibration of uncertainty estimates. We compare the model in terms of both image registration accuracy and uncertainty quantification to VoxelMorph, a state-of-the-art image registration model based on deep learning

    De novo transcriptome analysis of Perna viridis highlights tissue-specific patterns for environmental studies

    Get PDF
    published_or_final_versio

    Video-assisted mediastinoscopic transhiatal esophagectomy combined with laparoscopy for esophageal cancer

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Minimally invasive transhiatal esophagectomy for esophageal cancer includes mediastinoscopic and laparoscopic transhiatal esophagectomy. It is inadequate in both two techniques. It is impossible to dissect the lower esophagus with single mediastinoscopy or the upper and middle esophagus with single laparoscopy. We use mediastinoscopy combined with laparoscopy to dissect the whole esophagus and stomach including lymph node dissection. In addition, laparoscopic gastric mobilization leads to less trauma than an open gastroplasty.</p> <p>Methods</p> <p>40 cases of video-assisted mediastinoscopic transhiatal esophagectomy were performed and divided into two groups.32 patients were received surgical therapy of single mediastinoscopic esophagectomy with open gastroplasty in group A, while 8 patients were received surgical therapy of mediastinoscopic esophagectomy combined with laparoscopic lower esophageal and gastric dissection in group B. The perioperative complications were recorded.</p> <p>Results</p> <p>Video-assisted mediastinoscopic transhiatal esophagectomy was performed successfully both in group A and B. It suggested that mediastinoscopy combined with laparoscopy be better than single mediastinoscopy because of less blood loss, less pain, shorter ICU stay and complete lower mediastinal lymph nodes resection.</p> <p>Conclusions</p> <p>Video-assisted mediastinoscopic transhiatal esophagectomy combined with laparoscopy is a safe and minimally invasive technique with whole esophagus and mediastinal lymph node dissection in the clear visualization of the mediastinum, reducing the abdominal trauma.</p

    Evaluation of preoperative intra-aortic balloon pump in coronary patients with severe left ventricular dysfunction undergoing OPCAB surgery: early and mid-term outcomes

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The purpose of the present study was to evaluate the safety and the cost-effectiveness of using preoperative IABP as support compared with postoperative IABP treatment in coronary patients with severe left ventricular dysfunction (SLVD) who is undergoing off-pump coronary artery bypass surgery (OPCAB), including early outcomes, hospital mortality and morbidity, and mid-term follow-up outcomes.</p> <p>Methods</p> <p>Between March 2000 and December 2008, we prospectively and randomly studied the insertion of preoperative IABP in 115 (7.4%) and postoperative IABP in 106 (6.8%) of the 1560 consecutive patients. Group A is preoperative IABP therapy. Group B is postoperative IABP therapy.</p> <p>Results</p> <p>There was no significant difference in the number of grafts used between the two groups. Completeness of revascularization did not differ between the two groups. The statistically significant difference was hospital mortality (2.6% in group A vs. 3.8% in group B) (<it>p </it>< 0.05). And there was significant reduction in postoperative low cardiac output, malignant arrhythmia, acute renal failure and length of stay in ICU in group A, compared with group B (<it>p </it>< 0.05). In the two groups, six-, 12-, 24- and 48-month survival rates were similar. In the study the degree of improvement in angina and quality of life did not differ significantly between the two groups.</p> <p>Conclusion</p> <p>The use of preoperative IABP in SLVD patients undergoing OPCAB is of safety and effectiveness. The combined use of preoperative IABP and OPCAB allows complete revascularization in SLVD patients with an important reduction in operative mortality and excellent mid-term results.</p

    Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination

    Get PDF
    Lung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases.Nevertheless, in the published literatures,the LUS images may display a significant variation in technical execution,while scanning parameters may influence diagnostic accuracy.The inter- and intra-observer reliabilities of ultrasound exam have been extensively studied in general and in LUS.As expected,the reliability declines in the hands of novices when they perform the point-of-care ultrasound (POC US).Consequently,having appropriate guidelines regarding to technical aspects of neonatal LUS exam is very important especially because diagnosis is mainly based on interpretation of artifacts produced by the pleural line and the lungs.The present work aimed to create an instrument operation specification and parameter setting guidelines for neonatal LUS.Technical aspects and scanning parameter settings that allow for standardization in obtaining LUS images include (1)select a high-end equipment with high-frequency linear array transducer (12-14 MHz).(2)Choose preset suitable for lung examination or small organs.(3)Keep the probe perpendicular to the ribs or parallel to the intercostal space.(4)Set the scanning depth at 4-5 cm.(5)Set 1-2 focal zones and adjust them close to the pleural line.(6)Use fundamental frequency with speckle reduction 2-3 or similar techniques.(7)Turn off spatial compounding imaging.(8)Adjust the time-gain compensation to get uniform image from the near-to far-field

    Observation of a ppb mass threshoud enhancement in \psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) decay

    Full text link
    The decay channel ψπ+πJ/ψ(J/ψγppˉ)\psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) is studied using a sample of 1.06×1081.06\times 10^8 ψ\psi^\prime events collected by the BESIII experiment at BEPCII. A strong enhancement at threshold is observed in the ppˉp\bar{p} invariant mass spectrum. The enhancement can be fit with an SS-wave Breit-Wigner resonance function with a resulting peak mass of M=186113+6(stat)26+7(syst)MeV/c2M=1861^{+6}_{-13} {\rm (stat)}^{+7}_{-26} {\rm (syst)} {\rm MeV/}c^2 and a narrow width that is Γ<38MeV/c2\Gamma<38 {\rm MeV/}c^2 at the 90% confidence level. These results are consistent with published BESII results. These mass and width values do not match with those of any known meson resonance.Comment: 5 pages, 3 figures, submitted to Chinese Physics

    The Spin Structure of the Nucleon

    Full text link
    We present an overview of recent experimental and theoretical advances in our understanding of the spin structure of protons and neutrons.Comment: 84 pages, 29 figure

    The 'Positive Effect' is present in older Chinese adults: evidence from an eye tracking study

    Get PDF
    The 'Positive Effect' is defined as the phenomenon of preferential cognitive processing of positive affective information, and avoidance or dismissal of negative affective information in the social environment. The ‘Positive Effect’ is found for older people compared with younger people in western societies and is believed to reflect a preference for positive emotional regulation in older adults. It is not known whether such an effect is Universal, and in East Asian cultures, there is a highly controversial debate concerning this question. In the current experiment we explored whether Chinese older participants showed a 'Positive Effect' when they inspected picture pairs that were either a positive or a negative picture presented with a neutral picture, or a positive and negative picture paired together. The results indicated that both groups of participants showed an attentional bias to both pleasant (more processing of) and unpleasant pictures (initial orienting to) when these were paired with neutral pictures. When pleasant and unpleasant pictures were paired together both groups showed an initial orientation bias for the pleasant picture, but the older participants showed this bias for initial orienting and increased processing measures, providing evidence of a ‘Positive Effect’ in older Chinese adults
    corecore