1,457 research outputs found
The Time of Flight System of the AMS-02 Space Experiment
The Time-of-Flight (TOF) system of the AMS detector gives the fast trigger to
the read out electronics and measures velocity, direction and charge of the
crossing particles. The new version of the detector (called AMS-02) will be
installed on the International Space Station on March 2004. The fringing field
of the AMS-02 superconducting magnet is kG where the
photomultiplers (PM) are installed. In order to be able to operate with this
residual field, a new type of PM was chosen and the mechanical design was
constrained by requiring to minimize the angle between the magnetic field
vector and the PM axis. Due to strong field and to the curved light guides, the
time resolution will be ps, while the new electronics will allow
for a better charge measurement.Comment: 5 pages, 4 figures. Proc. of 7th Int. Conf. on Adv. Tech. and Part.
Phys., 15-19 October 2001,Como (Italy
Epidemiology of intensive care unit-acquired sepsis in Italy: results of the SPIN-UTI network
BACKGROUND:
Sepsis is the major cause of mortality from any infectious disease worldwide. Sepsis may be the result of a healthcare associated infection (HAI): the most frequent adverse events during care delivery especially in Intensive Care Units (ICUs). The main aim of the present study was to describe the epidemiology of ICU-acquired sepsis and related outcomes among patients enrolled in the framework of the Italian Nosocomial Infections Surveillance in ICUs - SPIN-UTI project.
STUDY DESIGN:
Prospective multicenter study.
METHODS:
The SPIN-UTI network adopted the European protocols for patient-based HAI surveillance.
RESULTS:
During the five editions of the SPIN-UTI project, from 2008 to 2017, 47.0% of HAIs has led to sepsis in 832 patients. Overall, 57.0% episodes were classified as sepsis, 20.5% as severe sepsis and 22.5% as septic shock. The most common isolated microorganisms from sepsis episodes were Acinetobacter baumannii, Klebsiella pneumoniae and Pseudomonas aeruginosa. The case fatality rate increased with the severity of sepsis and the mean length of ICU-stay was significantly higher in patients with ICU-acquired sepsis than in patients without.
CONCLUSION:
Our study provides evidence that ICU-acquired sepsis occurs frequently in Italian ICU patients and is associated with a high case fatality rate and increased length of stay. However, in order to explain these findings further analyses are needed in this population of ICU patient
The AMS-02 Time of Flight System. Final Design
The AMS-02 detector is a superconducting magnetic spectrometer that will
operate on the International Space Station. The time of flight (TOF) system of
AMS-02 is composed by four scintillator planes with 8, 8, 10, 8 counters each,
read at both ends by a total of 144 phototubes. This paper describes the new
design, the expected performances, and shows preliminary results of the ion
beam test carried on at CERN on October 2002.Comment: 4 pages, 6 EPS figures. Proc. of the 28th ICRC (2003
The AMS-02 RICH Imager Prototype - In-Beam Tests with 20 GeV/c per Nucleon Ions -
A prototype of the AMS Cherenkov imager (RICH) has been tested at CERN by
means of a low intensity 20 GeV/c per nucleon ion beam obtained by
fragmentation of a primary beam of Pb ions. Data have been collected with a
single beam setting, over the range of nuclear charges 2<Z<~45 in various beam
conditions and using different radiators. The charge Z and velocity beta
resolutions have been measured.Comment: 4 pages, contribution to the ICRC 200
The AMS-RICH velocity and charge reconstruction
The AMS detector, to be installed on the International Space Station,
includes a Ring Imaging Cerenkov detector with two different radiators, silica
aerogel (n=1.05) and sodium fluoride (n=1.334). This detector is designed to
provide very precise measurements of velocity and electric charge in a wide
range of cosmic nuclei energies and atomic numbers. The detector geometry, in
particular the presence of a reflector for acceptance purposes, leads to
complex Cerenkov patterns detected in a pixelized photomultiplier matrix. The
results of different reconstruction methods applied to test beam data as well
as to simulated samples are presented. To ensure nominal performances
throughout the flight, several detector parameters have to be carefully
monitored. The algorithms developed to fulfill these requirements are
presented. The velocity and charge measurements provided by the RICH detector
endow the AMS spectrometer with precise particle identification capabilities in
a wide energy range. The expected performances on light isotope separation are
discussed.Comment: Contribution to the ICRC07, Merida, Mexico (2007); Presenter: F.
Bara
the effects of the film thickness and roughness in the anodization process of very thin aluminum films
Introduction The anodization of aluminum foils having micrometer thickness is a common process and results in hexagonally self-ordered alumina membranes. However, anodic aluminum oxide (AAO) membranes fabricated from nanometer-thin films present new challenges to the anodization process, since aluminum films adheres poorly on supporting substrates and the smoothness of the film is highly related to the kind of substrate. In the current work we studied the effect of the aluminum thickness and roughness, using films ranging from 100 to 800 nm in thickness and from 2 to 15 nm in root means square roughness (on a scan area of 100 ÎĽm2), on the final alumina morphology. We deposited Al thin films by sputtering method on transparent conductive glass substrates. A strong dependence between the Al film roughness and the final alumina pore organization was observed. It was also determined that by reducing the Al film thickness, smaller Al grains were generated, leading to a homogenous pore formation. It was found that, for thicknesses below 300 nm, the electrolyte used to perform anodization becomes a critical parameter due to the competitive effect of aluminum delamination with respect to the anodization reaction. Phosphoric acid showed less delamination problems than oxalic acid
Changes in the expression of extracellular regulated kinase (ERK 1/2) in the R6/2 mouse model of Huntington's disease after phosphodiesterase IV inhibition
The mitogen-activated protein kinases (MAPKs) superfamily comprises three major signaling pathways: the extracellular signal-regulated protein kinases (ERKs), the c-Jun N-terminal kinases or stress-activated protein kinases (JNKs/SAPKs) and the p38 family of kinases.ERK 1/2 signaling has been implicated in a number of neurodegenerative disorders, including Huntington's disease (HD). Phosphorylation patterns of ERK 1/2 and JNK are altered in cell models of HD. In this study, we aimed at studying the correlations between ERK 1/2 and the neuronal vulnerability to HD degeneration in the R6/2 transgenic mouse model of HD. Single and double-label immunofluorescence for phospho-ERK (pERK, the activated form of ERK) and for each of the striatal neuronal markers were employed on perfusion-fixed brain sections from R6/2 and wild-type mice. Moreover, Phosphodiesterase 4 inhibition through rolipram was used to study the effects on pERK expression in the different types of striatal neurons. We completed our study with western blot analysis. Our study shows that pERK levels increase with age in the medium spiny striatal neurons and in the parvalbumin interneurons, and that rolipram counteracts such increase in pERK. Conversely, cholinergic and somatostatinergic interneurons of the striatum contain higher levels of pERK in the R6/2 mice compared to the controls. Rolipram induces an increase in pERK expression in these interneurons. Thus, our study confirms and extends the concept that the expression of phosphorylated ERK 1/2 is related to neuronal vulnerability and is implicated in the pathophysiology of cell death in HD. (C) 2012 Elsevier Inc. All rights reserved
- …