17 research outputs found

    Effects of biophysical stimulation in patients undergoing arthroscopic reconstruction of anterior cruciate ligament: prospective, randomized and double blind study

    Get PDF
    Pre-clinical studies have shown that treatment by pulsed electromagnetic fields (PEMFs) can limit the catabolic effects of pro-inflammatory cytokines on articular cartilage and favour the anabolic activity of the chondrocytes. Anterior cruciate ligament (ACL) reconstruction is usually performed by arthroscopic procedure that, even if minimally invasive, may elicit an inflammatory joint reaction detrimental to articular cartilage. In this study the effect of I-ONE PEMFs treatment in patients undergoing ACL reconstruction was investigated. The study end-points were (1) evaluation of patients’ functional recovery by International Knee Documentation Committee (IKDC) Form; (2) use of non-steroidal anti-inflammatory drugs (NSAIDs), necessary to control joint pain and inflammation. The study design was prospective, randomized and double blind. Sixty-nine patients were included in the study at baseline. Follow-up visits were scheduled at 30, 60 and 180 days, followed by 2-year follow-up interview. Patients were evaluated by IKDC Form and were asked to report on the use of NSAIDs. Patients were randomized to active or placebo treatments; active device generated a magnetic field of 1.5 mT at 75 Hz. Patients were instructed to use the stimulator (I-ONE) for 4 h per day for 60 days. All patients underwent ACL reconstruction with use of quadruple hamstrings semitendinosus and gracilis technique. At baseline there were no differences in the IKDC scores between the two groups. At follow-up visits the SF-36 Health Survey score showed a statistically significant faster recovery in the group of patients treated with I-ONE stimulator (P < 0.05). NSAIDs use was less frequent among active patients than controls (P < 0.05). Joint swelling resolution and return to normal range of motion occurred faster in the active treated group (P < 0.05) too. The 2-year follow-up did not shown statistically significant difference between the two groups. Furthermore for longitudinal analysis the generalized linear mixed effects model was applied to calculate the group × time interaction coefficient; this interaction showed a significant difference (P < 0.0001) between the active and placebo groups for all investigated variables: SF-36 Health Survey, IKDC Subjective Knee Evaluation and VAS. Twenty-nine patients (15 in the active group; 14 in the placebo group) underwent both ACL reconstruction and meniscectomy; when they were analysed separately the differences in SF-36 Health Survey scores between the two groups were larger then what observed in the whole study group (P < 0.05). The results of this study show that patient’s functional recovery occurs earlier in the active group. No side effects were observed and the treatment was well tolerated. The use of I-ONE should always be considered after ACL reconstruction, particularly in professional athletes, to shorten the recovery time, to limit joint inflammatory reaction and its catabolic effects on articular cartilage and ultimately for joint preservation

    Description of the attachment geometry of the anteromedial and posterolateral bundles of the ACL from arthroscopic perspective for anatomical tunnel placement

    Get PDF
    The anterior cruciate ligament (ACL) consists of an anteromedial bundle (AMB) and a posterolateral bundle (PLB). A reconstruction restoring the functional two-bundled nature should be able to approximate normal ACL function better than the most commonly used single-bundle reconstructions. Accurate tunnel positioning is important, but difficult. The purpose of this study was to provide a geometric description of the centre of the attachments relative to arthroscopically visible landmarks. The AMB and PLB attachment sites in 35 dissected cadaver knees were measured with a 3D system, as were anatomical landmarks of femur and tibia. At the femur, the mean ACL centre is positioned 7.9 ± 1.4 mm (mean ± 1 SD) shallow, along the notch roof, from the most lateral over-the-top position at the posterior edge of the intercondylar notch and from that point 4.0 ± 1.3 mm from the notch roof, low on the surface of the lateral condyle wall. The mean AMB centre is at 7.2 ± 1.8 and 1.4 ± 1.7 mm, and the mean PLB centre at 8.8 ± 1.6 and 6.7 ± 2.0 mm. At the tibia, the mean ACL centre is positioned 5.1 ± 1.7 mm lateral of the medial tibial spine and from that point 9.8 ± 2.1 mm anterior. The mean AMB centre is at 3.0 ± 1.6 and 9.4 ± 2.2 mm, and the mean PLB centre at 7.2 ± 1.8 and 10.1 ± 2.1 mm. The ACL attachment geometry is well defined relative to arthroscopically visible landmarks with respect to the AMB and PLB. With simple guidelines for the surgeon, the attachments centres can be found during arthroscopic single-bundle or double-bundle reconstructions

    Performance control after arthroscopic arthrolysis with capsulectomy in fresh-frozen elbow joints

    No full text
    Background and objective Posttraumatic or postoperative movement restrictions in elbow joints can often occur (including capsular contracture) and can generate everyday limitations. In persistent elbow stiffness, arthroscopic arthrolysis with removal of the dorsal and ventral capsule portions can be carried out. The purpose of this study was to assess the efficacy of arthroscopic capsulectomy by means of an in vitro anatomical study. Methods A standardized elbow arthroscopy with ventral and dorsal capsulectomy was performed and image-documented in five fresh-frozen elbow specimens. Subsequently, open dissection of the elbow joint was performed to analyze the amount of residual capsule by means of photodocumentation of the specimens. Results Regardless of the surgeon and surgical experience, anterior and posterior remnants of the capsule remained in all specimens. Dorsal capsule strands around the standard arthroscopy portals were noticed particularly more often in the area of the high dorsolateral camera portal. An incomplete capsulectomy was seen on the ulnar side at the level of the posterior medial ligament (PML) in the immediate vicinity of the ulnar nerve. Ventrally, a capsulectomy was performed from the radial side and also the ulnar side until the brachialis muscle and additionally a complete capsulectomy as far as the anterior medial ligament (AML) and radial collateral ligament (RCL) was achieved. The capsule was completely resected in a proximal direction. Distally, irrelevant capsular remnants were found in the region of the annular ligament and distal of the tip of the coronoid process. Conclusion Arthroscopic arthrolysis can be performed with a high degree of radicality. The radicality must be self-critically taken into account in one's own action. The radicality of the portal change may even be higher ventrally than with an isolated column procedure. On the other hand, it must be critically considered that posteriorly, the PML cannot be adequately addressed by means of arthroscopy due to the risk of ulnar nerve injury. Portal changes might help to enable a more complete visualization of the joint capsule and may avoid leaving possibly relevant remnants of the capsule. If a release of the PML is required, this may have to be carried out in combination with an ulnar nerve release in a mini-open technique

    LA RIFORMA DEL CODICE DELLA PROPRIETĂ€ INDUSTRIALE

    No full text
    Il 18 agosto 2010 è stato pubblicato sulla Gazzetta Ufficiale n. 192, ed è quindi entrato in vigore il successivo 2 settembre, il d.lgs. 13 agosto 2010, n. 131, approvato il 30 luglio dal Consiglio dei Ministri e recante la revisione del Codice della Proprietà Industriale: 130 articoli, che vanno ben al di là di un semplice decreto correttivo, ma delineano un vero e proprio “nuovo” Codice, caratterizzato da un approccio realistico, che tende a commisurare la protezione dei diritti di proprietà industriale a ciò che ciascuno di essi rappresenta sul mercato e, prima ancora, nel “mondo della vita”, delineando in questo modo un equilibrio tra esclusive e concorrenza, che si distacca decisamente dall’impostazione “proprietaria” a cui la Relazione al testo originario del Codice dichiarava di ispirarsi
    corecore