225 research outputs found

    Acceptance of non-invasive computed tomography coronary angiography: for a patient-friendly medicine

    Get PDF
    PURPOSE: This study was done to evaluate the psychological state and anxiety of patients undergoing computed tomography coronary angiography (CTCA), and assess their acceptance and satisfaction compared to invasive conventional coronary angiography (CCA). MATERIALS AND METHODS: A total of 442 consecutive patients (282 male; mean age 57.7 ± 9.5 years) who underwent CTCA for suspected or known coronary artery disease were evaluated with the Endler Multimodality Anxiety Scales (EMAS) before and after the scan, and a questionnaire administered after the scan. Among the 442 patients, 181 had a history of CCA. Two radiologists assessed the image quality of CTCA. RESULTS: Anxiety was more intense prior to the scan (EMAS score 51.7 vs. 46.7, p < 0.01) and in patients with a history of CCA (EMAS score 55.5 vs. 49.1, p < 0.01). Women presented more intense anxiety (EMAS score 59.5 vs. 47.3, p < 0.01), higher mean heart rate (63.5 ± 7.6 vs. 60.7 ± 7.3 beats per minute, p < 0.01) and a lower image quality than men (p < 0.0001). CTCA proved to be more acceptable than CCA because of accurate preparation, lower concern prior to the examination, negligible pain, higher comfort, and greater overall satisfaction (p < 0.0001). CONCLUSIONS: Computed tomography coronary angiography is a patient-friendly imaging method because of the minimal perceived discomfort. Anxiety may affect CTCA image quality in women

    Imaging features of pancreatic metastases: A comparison with pancreatic ductal adenocarcinoma

    Get PDF
    Purpose: To compare imaging features of pancreatic metastases (PM) with those of pancreatic ductal adenocarcinomas (PDAC). Methods: CT and MR scans of 24 patients with 54 PM and 30 patients with PDAC were reviewed to evaluate the imaging features, which were compared by using a Chi square test. Results: We found a statistically significant difference between PM and PDAC based on location (P < 0.001), margins (P < 0.001), arterial enhancement (P = 0.004), rim enhancement (P < 0.001), pancreatic duct dilatation (P = 0.01), common bile duct dilatation (P = 0.003), vascular involvement (P = 0.02), parenchymal atrophy (P < 0.001), peripancreatic fluid (P = 0.03). Conclusion: Imaging features might be helpful to differentiate PM from PDAC

    Dual Source Photon-Counting Computed Tomography-Part II: Clinical Overview of Neurovascular Applications

    Get PDF
    Photon-counting detector (PCD) is a novel computed tomography detector technology (photon-counting computed tomography-PCCT) that presents many advantages in the neurovascular field, such as increased spatial resolution, reduced radiation exposure, and optimization of the use of contrast agents and material decomposition. In this overview of the existing literature on PCCT, we describe the physical principles, the advantages and the disadvantages of conventional energy integrating detectors and PCDs, and finally, we discuss the applications of the PCD, focusing specifically on its implementation in the neurovascular field

    Dual-Source Photon-Counting Computed Tomography-Part I: Clinical Overview of Cardiac CT and Coronary CT Angiography Applications

    Get PDF
    The photon-counting detector (PCD) is a new computed tomography detector technology (photon-counting computed tomography, PCCT) that provides substantial benefits for cardiac and coronary artery imaging. Compared with conventional CT, PCCT has multi-energy capability, increased spatial resolution and soft tissue contrast with near-null electronic noise, reduced radiation exposure, and optimization of the use of contrast agents. This new technology promises to overcome several limitations of traditional cardiac and coronary CT angiography (CCT/CCTA) including reduction in blooming artifacts in heavy calcified coronary plaques or beam-hardening artifacts in patients with coronary stents, and a more precise assessment of the degree of stenosis and plaque characteristic thanks to its better spatial resolution. Another potential application of PCCT is the use of a double-contrast agent to characterize myocardial tissue. In this current overview of the existing PCCT literature, we describe the strengths, limitations, recent applications, and promising developments of employing PCCT technology in CCT

    Dual-Source Photon-Counting Computed Tomography-Part III: Clinical Overview of Vascular Applications beyond Cardiac and Neuro Imaging

    Get PDF
    Photon-counting computed tomography (PCCT) is an emerging technology that is expected to radically change clinical CT imaging. PCCT offers several advantages over conventional CT, which can be combined to improve and expand the diagnostic possibilities of CT angiography. After a brief description of the PCCT technology and its main advantages we will discuss the new opportunities brought about by PCCT in the field of vascular imaging, while addressing promising future clinical scenarios

    Atherosclerotic pattern of coronary myocardial bridging assessed with CT coronary angiography

    Get PDF
    The aim of our study was to evaluate the atherosclerotic pattern of patients with coronary myocardial bridging (MB) by means of CT Coronary Angiography (CT-CA). 254 consecutive patients (166 male, mean age 58.6 ± 10.3) who underwent 64-slice CT-CA according to current clinical indications were reviewed for the presence of MB and concomitant segmental atherosclerotic pattern. Coronary plaques were assessed in all patients enrolled. 73 patients (29%) presented single (90%) or multiple (10%) MB, frequently (93%) localized in the mid-distal left anterior descending artery. The MB segment was always free of atherosclerosis. Segments proximal to the MB presented: no atherosclerotic disease (n = 37), positive remodeling (n = 23), 50% stenoses (n = 7). Distal segments presented a different atherosclerosis pattern (P < 0.0001): absence of disease (n = 73), no significant lesions (n = 8). No significant differences were found between segments proximal to MB and proximal coronary segments apart from left main trunk. Pattern of atherosclerotic lesions located in segments 6 and 7 significantly differs between patients with MB and patients without MB (P < 0.05). CT-CA is a reliable method to non-invasively demonstrate MB and related atherosclerotic pattern. CT-CA provides new insight regarding atherosclerosis distribution in segments close to MB

    Influence of convolution filtering on coronary plaque attenuation values: observations in an ex vivo model of multislice computed tomography coronary angiography

    Get PDF
    Attenuation variability (measured in Hounsfield Units, HU) of human coronary plaques using multislice computed tomography (MSCT) was evaluated in an ex vivo model with increasing convolution kernels. MSCT was performed in seven ex vivo left coronary arteries sunk into oil followingthe instillation of saline (1/∞) and a 1/50 solution of contrast material (400 mgI/ml iomeprol). Scan parameters were: slices/collimation, 16/0.75 mm; rotation time, 375 ms. Four convolution kernels were used: b30f-smooth, b36f-medium smooth, b46f-medium and b60f-sharp. An experienced radiologist scored for the presence of plaques and measured the attenuation in lumen, calcified and noncalcified plaques and the surrounding oil. The results were compared by the ANOVA test and correlated with Pearson’s test. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. The mean attenuation values were significantly different between the four filters (p < 0.0001) in each structure with both solutions. After clustering for the filter, all of the noncalcified plaque values (20.8 ± 39.1, 14.2 ± 35.8, 14.0 ± 32.0, 3.2 ± 32.4 HU with saline; 74.7 ± 66.6, 68.2 ± 63.3, 66.3 ± 66.5, 48.5 ± 60.0 HU in contrast solution) were significantly different, with the exception of the pair b36f–b46f, for which a moderate-high correlation was generally found. Improved SNRs and CNRs were achieved by b30f and b46f. The use of different convolution filters significantly modifief the attenuation values, while sharper filtering increased the calcified plaque attenuation and reduced the noncalcified plaque attenuation
    • …
    corecore