212 research outputs found

    Diagnosis and endovascular treatment of an internal mammary artery injury

    Get PDF
    Internal mammary artery (IMA) disruption after blunt chest trauma is rare. In some instances, it may occur after mild chest trauma with minor external physical findings. However, prompt diagnosis and treatment are necessary, as it can be associated with vascular and parenchymal injuries. We report a case of blunt chest trauma resulting in a sternal fracture associated with an IMA injury, active anterior mediastinal bleeding, bilateral lung contusions, and a left hemothorax. It was successfully treated by selective embolization to the left IMA branch and chest tube placement

    Inflammatory markers as prognostic factors of survival in patients affected by hepatocellular carcinoma undergoing transarterial chemoembolization

    Get PDF
    Transarterial chemoembolization (TACE) is a good choice for hepatocellular carcinoma (HCC) treatment when surgery and liver transplantation are not feasible. Few studies reported the value of prognostic factors influencing survival after chemoembolization. In this study, we evaluated whether preoperative inflammatory factors such as neutrophil to lymphocyte ratio and platelet to lymphocyte ratio affected our patient survival when affected by hepatocellular carcinoma. Methods. We retrospectively evaluated a total of 72 patients with hepatocellular carcinoma that underwent TACE. We enrolled patients with different etiopathogeneses of hepatitis and histologically proven HCC not suitable for surgery. The overall study population was dichotomized in two groups according to the median NLR value and was analyzed also according to other prognostic factors. Results. The global median overall survival (OS) was 28 months. The OS in patients with high NLR was statistically significantly shorter than that in patients with low NLR. The following pretreatment variables were significantly associated with the OS in univariate analyses: age, Child-Pugh score, BCLC stage, INR, and NLR. Pretreated high NLR was an independently unfavorable factor for OS. Conclusion. NLR could be considered a good prognostic factor of survival useful to stratify patients that could benefit from TACE treatment

    The utility of the 3D imaging software in the macroscopic rendering of complex gynecologic specimens

    Get PDF
    A new generation of three dimensional (3D) imaging software for the anatomical rendering of the human body, and related surgical pathologies, is postulated. Its practical application is underlined

    Contrast enhanced ultrasound (CEUS) in blunt abdominal trauma.

    Get PDF
    In the assessment of polytrauma patient, an accurate diagnostic study protocol with high sensitivity and specificity is necessary. Computed Tomography (CT) is the standard reference in the emergency for evaluating the patients with abdominal trauma. Ultrasonography (US) has a high sensitivity in detecting free fluid in the peritoneum, but it does not show as much sensitivity for traumatic parenchymal lesions. The use of Contrast-Enhanced Ultrasound (CEUS) improves the accuracy of the method in the diagnosis and assessment of the extent of parenchymal lesions. Although the CEUS is not feasible as a method of first level in the diagnosis and management of the polytrauma patient, it can be used in the follow-up of traumatic injuries of abdominal parenchymal organs (liver, spleen and kidneys), especially in young people or children

    MOKA3D: An innovative approach to 3D gas kinematic modelling. I. Application to AGN ionized outflows

    Full text link
    Studying the feedback process of Active Galactic Nuclei (AGN) requires characterising multiple kinematical components, such as rotating gas and stellar disks, outflows, inflows, and jets. To compare the observed properties with theoretical predictions of galaxy evolution and feedback models and to assess the mutual interaction and energy injection rate into the interstellar medium (ISM), one usually relies on simplified kinematic models. These models have several limitations, as they often do not take into account projection effects, beam smearing and the surface brightness distribution of the emitting medium. Here, we present MOKA3D, an innovative approach to model the 3D gas kinematics from integral field spectroscopy observations. In this first paper, we discuss its application to the case of AGN ionised outflows, whose observed clumpy emission and apparently irregular kinematics are only marginally accounted for by existing kinematical models. Unlike previous works, our model does not assume the surface brightness distribution of the gas, but exploits a novel procedure to derive it from the observations by reconstructing the 3D distribution of emitting clouds and providing accurate estimates of the spatially resolved outflow physical properties (e.g. mass rate, kinetic energy). As an example, we demonstrate the capabilities of our method by applying it to three nearby Seyfert-II galaxies observed with MUSE at the VLT and selected from the MAGNUM survey, showing that the complex kinematic features observed can be described by a conical outflow with a constant radial velocity field and a clumpy distribution of clouds.Comment: 17 pages, 14 figure

    Castel di Sangro-Scontrone field camp – structural and applied geomorphology

    Get PDF
    The Geomorphological Field Camp 2014 in the Castel di Sangro-Scontrone area is the result of geological and geomorphological teaching field work activities carried out in Central Italy by a group of 23 students attending the Structural Geomorphology and Applied Geomorphology courses (Master's Degree in Geological Science and Technology of the Università degli Studi ‘G. d'Annunzio’ Chieti-Pescara, Italy, Department of Engineering and Geology). The Field Camp 2014 was organized in May 2014, following regular classes held during the fall term. General activities for the field camp were developed over four main stages: (1) preliminary analysis of the regional geological and geomorphological setting of the area; (2) preliminary activities for the analysis of the local area (orography, hydrography and photogeology investigations, and geographical information system processing); (3) field work, focused on the analysis of a specific issue concerning structural geomorphology or applied geomorphology (e.g. landscape evolution, river channel change, landslide distribution, and flood hazard); and (4) post-field work production of the map. Finally, the fundamental role of field work in the analysis of landscape and in land management was outlined: indeed, the overall field camp enhanced the crucial role of field-based learning for young geomorphologists in order to acquire a strong sensitivity to geomorphological processes and landscape evolution

    MUSE AO spectroscopy confirms five dual AGNs and two strongly lensed QSOs at sub-arcsec separation

    Full text link
    The novel Gaia Multi Peak (GMP) technique has proven to be able to successfully select dual and lensed AGN candidates at sub-arcsec separations. Both populations are important because dual AGNs represent one of the central, still largely untested, predictions of lamdaCDM cosmology, and compact lensed quasars allow to probe the central regions of the lensing galaxies. In this work, we present high spatial resolution spectroscopy of twelve GMP-selected systems. We use the the adaptive-optics assisted integral-field spectrograph MUSE at VLT to resolve each system and study the nature of each component. All the targets reveal the presence of two components confirming the GMP selection. We classify five targets as dual AGNs, two as lensed systems, and five as a chance alignment of a star and and AGN. Having separations between 0.30" and 0.86", these dual and lensed systems are, to date, among the most compact ever discovered at z >0.3. This is the largest sample of distant dual AGNs with sub-arcsec separations ever presented in a single paper.Comment: 11 pages, 9 figure

    Multiaxial Fatigue Assessment of Friction Stir Welded Tubular Joints of Al 6082-T6

    Get PDF
    The present paper addresses the problem of designing aluminium friction stir (FS) welded joints against multiaxial fatigue. After developing a bespoke FS welding technology suitable for joining aluminium tubes, some one hundred welded tubular specimens of Al 6082-T6 were tested under pure axial, pure torsional and biaxial tension-torsion loading. The influence was explored of two independent variables, namely the proportional or nonproportional nature of the biaxial loading and the effect of axial and torsional non-zero mean stresses. The experimental results were re-analysed using the Modified Wöhler Curve Method (MWCM), with this bi-parametrical critical plane approach being applied in terms of nominal stresses, notch stresses, and also the Point Method. The validation exercise carried out using these experimental data demonstrated that the MWCM is applicable to prediction of the fatigue lives for these FS welded joints, with its use resulting in life estimates that fall within the uniaxial and torsional calibration scatter bands. The approach proposed in the present paper offers, for the first time, a complete solution to the problem of designing tubular FS welded joints against multiaxial fatigue loading

    GMP-selected dual and lensed AGNs: selection function and classification based on near-IR colors and resolved spectra from VLT/ERIS, KECK/OSIRIS, and LBT/LUCI

    Full text link
    The Gaia-Multi-Peak (GMP) technique can be used to identify large numbers of dual or lensed AGN candidates at sub-arcsec separation, allowing us to study both multiple SMBHs in the same galaxy and rare, compact lensed systems. The observed samples can be used to test the predictions of the models of SMBH merging once 1) the selection function of the GMP technique is known, and 2) each system has been classified as dual AGN, lensed AGN, or AGN/star alignment. Here we show that the GMP selection is very efficient for separations above 0.15'' when the secondary (fainter) object has magnitude G<20.5. We present the spectroscopic classification of five GMP candidates using VLT/ERIS and Keck/OSIRIS, and compare them with the classifications obtained from: a) the near-IR colors of 7 systems obtained with LBT/LUCI, and b) the analysis of the total, spatially-unresolved spectra. We conclude that colors and integrated spectra can already provide reliable classifications of many systems. Finally, we summarize the confirmed dual AGNs at z>0.5 selected by the GMP technique, and compare this sample with other such systems from the literature, concluding that GMP can provide a large number of confirmed dual AGNs at separations below 7 kpc.Comment: 14 pages,A&A, in pres

    GMP-selected dual and lensed AGNs: Selection function and classification based on near-IR colors and resolved spectra from VLT/ERIS, Keck/OSIRIS, and LBT/LUCI

    Get PDF
    The Gaia Multipeak (GMP) technique can be used to identify large numbers of dual or lensed active galactic nucleus (AGN) candidates at subarcsec separation, allowing us to study both multiple supermassive black holes (SMBHs) in the same galaxy and rare, compact lensed systems. The observed samples can be used to test the predictions of the models of SMBH merging when (1) the selection function of the GMP technique is known, and (2) each system has been classified as a dual AGN, a lensed AGN, or an AGN/star alignment. Here we show that the GMP selection is very efficient for separations above 0:15′′ when the secondary (fainter) object has a magnitude G ≤ 20:5. We present the spectroscopic classification of five GMP candidates using VLT/ERIS and Keck/OSIRIS and compare them with the classifications obtained from (a) the near-IR colors of seven systems obtained with LBT/LUCI, and (b) the analysis of the total spatially unresolved spectra. We conclude that colors and integrated spectra can already provide reliable classifications of many systems. Finally, we summarize the confirmed dual AGNs at z &gt; 0:5 selected by the GMP technique, and compare this sample with other such systems from the literature, concluding that GMP can provide a large number of confirmed dual AGNs at separations below 7 kpc
    • …
    corecore