579 research outputs found

    Cluster Dynamics for Randomly Frustrated Systems with Finite Connectivity

    Full text link
    In simulations of some infinite range spin glass systems with finite connectivity, it is found that for any resonable computational time, the saturatedenergy per spin that is achieved by a cluster algorithm is lowered in comparison to that achieved by Metropolis dynamics.The gap between the average energies obtained from these two dynamics is robust with respect to variations of the annealing schedule. For some probability distribution of the interactions the ground state energy is calculated analytically within the replica symmetry assumptionand is found to be saturated by a cluster algorithm.Comment: Revtex, 4 pages with 3 figure

    The development, usability, and reliability of the Electronic Patient Visit Assessment (ePVA) for head and neck cancer

    Get PDF
    Background: Annually, over 65,000 persons are diagnosed with head and neck cancer in the United States. During treatment, up to 50% of patients become severely symptomatic with pain, fatigue, mouth sores, and inability to eat. Long term complications are lymphedema, fibrosis, dysphagia, and musculoskeletal impairment. Patients’ ability to perform daily activities and to interact socially may be impaired, resulting in poor quality of life. A pragmatic, clinically useful assessment is needed to ensure early detection and intervention for patients to report symptoms and functional limitations over time. We developed the Electronic Patient Visit Assessment (ePVA) that enables patients to report 42 symptoms related to head and neck cancer and 17 limitations of functional status. This manuscript reports (I) the development of the ePVA, (II) the content validity of the ePVA, and (III) the usability and reliability of the ePVA. Methods: Usability was evaluated using the “Think Aloud” technique to guide the iterative process to refine the ePVA based on participants’ evaluations. After signing the informed consent, 30 participants with head and neck cancer completed the ePVA using digital tablet devices while thinking aloud about ease of use. All patient conversations were recorded and professionally transcribed. Reliability of the ePVA symptom and functional limitation measures was estimated using the Kuder-Richardson test. Convergent validity of the ePVA was evaluated using the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30 global QoL/health scale. Transcribed qualitative data were analyzed using directed content analysis approach. Quantitative analyses consisted of descriptive statistics and correlation analyses. Results: Among participants, 90% strongly agreed or agreed that the ePVA system was easy to use and 80% were very satisfied. Only minor usability problems were reported due to formatting and software “bugs”. Reporting of usability problems decreased in frequency over the study period and no usability problems were reported by the last 3 participants who completed the ePVA. Based on participants’ suggestions during the iterative process, refinement of the ePVA included increased touch sensitivity of the touch screen technology and customized error messages to improve ease of use. The ePVA also recorded patient reported symptoms (mouth symptoms: 93%, fibrosis: 60%, fatigue: 60%). The ePVA demonstrated acceptable reliability (alpha =0.82–0.85) and convergent validity (ePVA total number of reported symptoms and function limitations was negatively correlated with EORTC QLQ-C30 global QOL/health scale: r=−0.55038, P<0.01). Conclusions: The ePVA was rigorously developed, accepted by patients with satisfaction, and demonstrated acceptable reliability and convergent validity. Future research will use data generated by the ePVA to determine the impact of symptom trajectories on functional status, treatment interruptions and terminations, and health resource use in head and neck cancer

    The usefulness of the electronic patient visit assessment (ePVA) as a clinical support tool for real-time interventions in head and neck cancer

    Get PDF
    Background: Patients with head and neck cancer (HNC) experience painful, debilitating symptoms and functional limitations that can interrupt cancer treatment, and decrease their health-related quality of life (HRQoL). The Electronic Patient Visit Assessment (ePVA) for head and neck is a web-based mHealth patient-reported measure that asks questions about 21 categories of symptoms and functional limitations common to HNC. This article presents the development and usefulness of the ePVA as a clinical support tool for real-time interventions for patient-reported symptoms and functional limitations in HNC. Methods: Between January 2018 and August 2019, 75 participants were enrolled in a clinical usefulness study of the ePVA. Upon signing informed consent, participants completed the ePVA and the European Organization for Research and Treatment of Cancer (EORTC) Quality of Life Questionnaire (QLQ) general (C30) questionnaire v3.0 (scores range from 0 to 100 with 100 representing best HRQoL). Clinical usefulness of the ePVA was defined as demonstration of reliability, convergent validity with HRQoL, and acceptability of the ePVA (i.e., >70% of eligible participants complete the ePVA at two or more visits and >70% of ePVA reports are read by providers). Formal focus group discussions with the interdisciplinary teamthat cared for patients with HNC guided the development of the ePVA as a clinical support tool. Qualitative and quantitative methods were used throughout the study. Descriptive statistics consisting of means and frequencies, Pearson correlation coefficient, and Student’s t-tests were calculated using SAS 9.4 and STATA. Results: The participants were primarily male (71%), White (76%), diagnosed with oropharyngeal or oralcavity cancers (53%), and undergoing treatment for HNC (69%). Data analyses supported the reliability (alpha =0.85), convergent validity with HRQoL scores, and acceptability of the ePVA. Participants with the highest number of symptoms and functional limitations reported significantly worse HRQoL (sumof symptoms: r=–0.50, P<0.0001; sum of function limitations: r=–0.56, P<0.0001). Ninety-two percent of participants (59 of 64) who had follow-up visits within the 6-month study period completed the ePVA at twoor more visits and providers read 89% (169 of 189) of automated ePVA reports. The use of the ePVA as aclinical support tool for real-time interventions for symptoms and functional limitations reported by patients is described in a clinical exemplar. Conclusions: This research indicates that the ePVA may be a useful mHealth tool as a clinical support tool for real-time interventions for patient-reported symptoms and functional limitations in HNC. The study findings support future translational research to enhance the usefulness of the ePVA in real world settings for early interventions that decrease symptom burden and improve the QoL of patients with HNC

    Automatic mental processes, automatic actions and behaviours in game transfer phenomena: an empirical self-report study using online forum data

    Get PDF
    Previous studies have demonstrated that the playing of videogames can have both intended and unintended effects. The purpose of this study was to investigate the influence of videogames on players’ mental processes and behaviours in day-to-day settings. A total of 1,023 self-reports from 762 gamers collected from online videogame forums were classified, quantified, described and explained. The data include automatic thoughts, sensations and impulses, automatic mental replays of the game in real life, and voluntary/involuntary behaviours with videogame content. Many gamers reported that they had responded – at least sometimes – to real life stimuli as if they were still playing videogames. This included overreactions, avoidances, and involuntary movements of limbs. These experiences lasted relatively short periods of time but in a minority of players were recurrent. The gamers' experiences appeared to be enhanced by virtual embodiment, repetitive manipulation of game controls, and their gaming habits. However, similar phenomena may also occur when doing other non-gaming activities. The implications of these game transfer experiences are discussed

    Comparison of new forms of creatine in raising plasma creatine levels

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Previous research has shown that plasma creatine levels are influenced by extracellular concentrations of insulin and glucose as well as by the intracellular creatine concentration. However, the form of creatine administered does not appear to have any effect although specific data on this is lacking. This study examined whether the administration of three different forms of creatine had different effects on plasma creatine concentrations and pharmacokinetics.</p> <p>Methods</p> <p>Six healthy subjects (three female and three male subjects) participated in the study. Each subject was assigned to ingest a single dose of isomolar amounts of creatine (4.4 g) in the form of creatine monohydrate (CrM), tri-creatine citrate (CrC), or creatine pyruvate (CrPyr) using a balanced cross-over design. Plasma concentration curves, determined over eight hours after ingestion, were subject to pharmacokinetic analysis and primary derived data were analyzed by repeated measures ANOVA.</p> <p>Results</p> <p>Mean peak concentrations and area under the curve (AUC) were significantly higher with CrPyr (17 and 14%, respectively) in comparison to CrM and CrC. Mean peak concentration and AUC were not significantly different between CrM and CrC. Despite the higher peak concentration with CrPyr there was no difference between the estimated velocity constants of absorption (ka) or elimination (kel) between the three treatments. There was no effect of treatment with CrPyr on the plasma pyruvate concentration.</p> <p>Conclusion</p> <p>The findings suggest that different forms of creatine result in slightly altered kinetics of plasma creatine absorption following ingestion of isomolar (with respect to creatine) doses of CrM, CrC and CrPyr although differences in ka could not be detected due to the small number of blood samples taken during the absorption phase. Characteristically this resulted in higher plasma concentrations of creatine with CrPyr. Differences in bioavailability are thought to be unlikely since absorption of CrM is already close to 100%. The small differences in kinetics are unlikely to have any effect on muscle creatine elevation during periods of creatine loading.</p

    Non-universal current flow near the metal-insulator transition in an oxide interface

    Full text link
    In systems near phase transitions, macroscopic properties often follow algebraic scaling laws, determined by the dimensionality and the underlying symmetries of the system. The emergence of such universal scaling implies that microscopic details are irrelevant. Here, we locally investigate the scaling properties of the metal-insulator transition at the LaAlO3/SrTiO3 interface. We show that, by changing the dimensionality and the symmetries of the electronic system, coupling between structural and electronic properties prevents the universal behavior near the transition. By imaging the current flow in the system, we reveal that structural domain boundaries modify the filamentary flow close to the transition point, preventing a fractal with the expected universal dimension from forming. Our results offer a generic platform to engineer electronic transitions on the nanoscale.Comment: 19 pages, 6 figure

    Ground states of two-dimensional ±\pmJ Edwards-Anderson spin glasses

    Full text link
    We present an exact algorithm for finding all the ground states of the two-dimensional Edwards-Anderson ±J\pm J spin glass and characterize its performance. We investigate how the ground states change with increasing system size and and with increasing antiferromagnetic bond ratio xx. We find that that some system properties have very large and strongly non-Gaussian variations between realizations.Comment: 15 pages, 21 figures, 2 tables, uses revtex4 macro
    • 

    corecore