200 research outputs found

    Technical Note: REFIR-PAD level 1 data analysis and performance characterization

    Get PDF
    The outgoing long-wave radiation from the Earth's atmosphere in the far infrared spectral region is mostly unexplored, while is well recognized that the water vapour contribution to greenhouse trapping is dominant in this region. The Radiation Explorer in the Far InfraRed (REFIR) study has proven the feasibility of a space-borne Fourier transform spectrometer able to perform the measurement in the 100–1100 cm<sup>−1</sup> range with a resolution of 0.5 cm<sup>−1</sup>. Following this work a prototype of the spectrometer named REFIR-PAD (Prototype for Applications and Development) has been developed to observe the atmospheric radiance from both ground-based sites and from stratospheric balloon platforms. In this work we describe the REFIR-PAD level 1 data analysis procedure, that, starting from raw instrumental data produces the calibrated atmospheric spectral radiance. Performances of the procedure are also described

    Nanoparticles-cell association predicted by protein corona fingerprints

    Get PDF
    In a physiological environment (e.g., blood and interstitial fluids) nanoparticles (NPs) will bind proteins shaping a "protein corona" layer. The long-lived protein layer tightly bound to the NP surface is referred to as the hard corona (HC) and encodes information that controls NP bioactivity (e.g. cellular association, cellular signaling pathways, biodistribution, and toxicity). Decrypting this complex code has become a priority to predict the NP biological outcomes. Here, we use a library of 16 lipid NPs of varying size (Ø ≈ 100-250 nm) and surface chemistry (unmodified and PEGylated) to investigate the relationships between NP physicochemical properties (nanoparticle size, aggregation state and surface charge), protein corona fingerprints (PCFs), and NP-cell association. We found out that none of the NPs' physicochemical properties alone was exclusively able to account for association with human cervical cancer cell line (HeLa). For the entire library of NPs, a total of 436 distinct serum proteins were detected. We developed a predictive-validation modeling that provides a means of assessing the relative significance of the identified corona proteins. Interestingly, a minor fraction of the HC, which consists of only 8 PCFs were identified as main promoters of NP association with HeLa cells. Remarkably, identified PCFs have several receptors with high level of expression on the plasma membrane of HeLa cells

    Measurement of the water vapour vertical profile and of the Earth's outgoing far infrared flux

    No full text
    International audienceOur understanding of global warming depends on the accuracy with which the atmospheric components that modulate the Earth's radiation budget are known. Many uncertainties still exist on the radiative effect of water in the different spectral regions, among which the far infrared where few observations have been made. An assessment is shown of the atmospheric outgoing flux obtained from a balloon-borne platform with wideband spectrally resolved nadir measurements at the top-of-atmosphere over the full spectral range, including the far infrared, from 100 to 1400 cm?1, made by a Fourier transform spectrometer with uncooled detectors. From these measurements, we retrieve 15 pieces of information about water vapour and temperature profiles, and surface temperature, with a precision of 5% for the mean water vapour profile and a major improvement of the upper troposphere-lower stratosphere knowledge. The retrieved atmospheric state makes it possible to calculate the emitted radiance as a function of the zenith angle and to determine the outgoing radiation flux, proving that spectrally resolved observations can be used to derive accurate information on the integrated flux. While the retrieved temperature is in good agreement with ECMWF analysis, the retrieved water vapour profile differs significantly, and, depending on time and location, the derived flux differs in the far infrared (0?600 cm?1) from that derived from ECMWF by 2?3.5 W/m2±0.4 W/m2. The observed discrepancy is larger than current estimates of radiative forcing due to CO2 increases since pre-industrial time. The error with which the flux is determined is caused mainly by calibration uncertainties while detector noise has a negligible effect, proving that uncooled detectors are adequate for top of the atmosphere radiometry

    Au Nanoparticles Decorated Graphene-Based Hybrid Nanocomposite for As(III) Electroanalytical Detection

    Get PDF
    Electrochemical sensors integrating hybrid nanostructured platforms are a promising alternative to conventional detection techniques for addressing highly relevant challenges of heavy metal determination in the environment. Hybrid nanocomposites based on graphene derivatives and inorganic nanoparticles (NPs) are ideal candidates as active materials for detecting heavy metals, as they merge the relevant physico-chemical properties of both the components, finally leading to a rapid and sensitive current response. In this work, a hybrid nanocomposite formed of reduced graphene oxide (RGO) sheets, surface functionalized by π-π interactions with 1-pyrene carboxylic acid (PCA), and decorated in situ by Au NPs, was synthesized by using a colloidal route. The hybrid nanocomposite was characterized by cyclic voltammetry and electrochemical impedance spectroscopy with respect to the corresponding single components, both bare and deposited as a layer-by-layer junction onto the electrode. The results demonstrated the high electrochemical activity of the hybrid nanocomposite with respect to the single components, highlighting the crucial role of the nanostructured surface morphology of the electrode and the PCA coupling agent at the NPs-RGO interphase in enhancing the nanocomposite electroactivity. Finally, the Au NP-decorated PCA-RGO sheets were tested by anodic stripping voltammetry of As(III) ion—a particularly relevant analyte among heavy metal ions—in order to assess the sensing ability of the nanocomposite material with respect to its single components. The nanocomposite has been found to present a sensitivity higher than that characterizing the bare components, with LODs complying with the directives established by the U.S. EPA and in line with those reported for state-of-the-art electrochemical sensors based on other Au-graphene nanocomposites

    Polystyrene perturbs the structure, dynamics, and mechanical properties of DPPC membranes: An experimental and computational study

    Get PDF
    Synthetic plastic oligomers can interact with the cells of living organisms by different ways. They can be intentionally administered to the human body as part of nanosized biomedical devices. They can be inhaled by exposed workers, during the production of multicomponent, polymer-based nanocomposites. They can leak out of food packaging. Most importantly, they can result from the degradation of plastic waste, and enter the food chain. A physicochemical characterization of the effects of synthetic polymers on the structure and dynamics of cell components is still lacking. Here, we combine a wide spectrum of experimental techniques (calorimetry, x-ray, and neutron scattering) with atomistic Molecular Dynamics simulations to study the interactions between short chains of polystyrene (25 monomers) and model lipid membranes (DPPC, in both gel and fluid phase). We find that doping doses of polystyrene oligomers alter the thermal properties of DPPC, stabilizing the fluid lipid phase. They perturb the membrane structure and dynamics, in a concentration-dependent fashion. Eventually, they modify the mechanical properties of DPPC, reducing its bending modulus in the fluid phase. Our results call for a systematic, interdisciplinary assessment of the mechanisms of interaction of synthetic, everyday use polymers with cell membranes

    Amperometric separation-free immunosensor for real-time environmental monitoring

    Get PDF
    Immunoanalytical techniques have found widespread use due to the characteristics of specificity and wide applicability for many analytes, from large polymer antigens, to simple haptens, and even single atoms. Electrochemical sensors offer benefits of technical simplicity, speed and convenience via direct transduction to electronic equipment. Together, these two systems offer the possibility of a convenient, ubiquitous assay technique with high selectivity. However, they are still not widely used, mainly due to the complexity of the associated immunoassay methodologies. A separation-free immunoanalytical technique is described here, which has allowed for the analysis of atrazine in real time and in both quasi-equilibrium and stirred batch configurations. It illustrated that determinations as low as 0.13 muM (28 ppb) could be made using equilibrium incubation with an analytical range of 0.1-10 muM. Measurements could be made between 1 and 10 mM within several minutes using a real-time, stirred batch method. This system offers the potential for fast, simple, cost-effective biosensors for the analysis of many substances of environmental, biomedical and pharmaceutical concern. (C) 2001 Elsevier Science B.V. All rights reserved
    • …
    corecore