48 research outputs found

    Automated distal coronary bypass with a novel magnetic coupler (MVP system)

    Get PDF
    AbstractObjectiveWe sought to assess the feasibility of performing sutureless distal coronary artery bypass anastomoses with a novel magnetic coupling device.MethodsFrom May 2000 to April 2001, single-vessel side-to-side coronary artery bypass grafting on a beating heart was performed in 39 domestic white pigs (35-60 kg) without the use of mechanical stabilization, shunts, or perfusion bridges. Animals were divided into 2 groups. Seventeen pigs underwent right internal thoracic artery to right coronary artery bypass grafting through a median sternotomy (group 1) with a novel magnetic vascular positioning system (MVP system; Ventrica, Inc, Fremont, Calif). Twenty-two pigs underwent left internal thoracic artery to left anterior descending artery grafting with the MVP anastomotic device through a left anterior minithoracotomy (group 2). This system consists of 2 pairs of elliptical magnetic implants and a deployment device. One pair of magnets forms the anastomotic docking port within the graft; the other pair forms an identical anastomotic docking port within the target vessel. The anastomosis is created when the 2 docking ports magnetically couple. Anastomotic patency was evaluated by means of angiography during the first postoperative week and at 1 month. Histologic studies were performed at different time points as late as 6 months.ResultsRight internal thoracic artery to right coronary artery anastomoses and left internal thoracic artery to left anterior descending artery anastomoses were successfully performed with the system in all animals. The self-adherent and self-aligning properties of the implants allowed for immediate and secure approximation of the arteries (total anastomotic time between 2-3 minutes). Anastomoses were constructed without a stabilization platform. Five nondevice-related deaths occurred postoperatively. One-week angiography, performed in 35 surviving animals, showed a patent graft and anastomosis in all cases. The patency rate at 1 month was 97% (33/34). Histologic studies as late as 6 months demonstrated neointimal coverage of the magnets without any significant luminal obstruction. Histology also confirmed the presence of viable tissue between magnets.ConclusionThe MVP anastomotic system uses magnetic force to create rapid and secure distal coronary artery anastomoses, which might facilitate minimally invasive and totally endoscopic coronary artery bypass surgery

    Therapeutic decision-making for patients with fluctuating mitral regurgitation

    Get PDF
    Mitral regurgitation (MR) is a common, progressive, and difficult-to-manage disease. MR is dynamic in nature, with physiological fluctuations occurring in response to various stimuli such as exercise and ischaemia, which can precipitate the development of symptoms and subsequent cardiac events. In both chronic primary and secondary MR, the dynamic behaviour of MR can be reliably examined during stress echocardiography. Dynamic fluctuation of MR can also have prognostic value; patients with a marked increase in regurgitant volume or who exhibit increased systolic pulmonary artery pressure during exercise have lower symptom-free survival than those who do not experience significant changes in MR and systolic pulmonary artery pressure during exercise. Identifying patients who have dynamic MR, and understanding the mechanisms underlying the condition, can potentially influence revascularization strategies (such as the surgical restoration of coronary blood flow) and interventional treatment (including cardiac resynchronization therapy and new approaches targeted to the mitral valve)

    Methods of estimation of mitral valve regurgitation for the cardiac surgeon

    Get PDF
    Mitral valve regurgitation is a relatively common and important heart valve lesion in clinical practice and adequate assessment is fundamental to decision on management, repair or replacement. Disease localised to the posterior mitral valve leaflet or focal involvement of the anterior mitral valve leaflet is most amenable to mitral valve repair, whereas patients with extensive involvement of the anterior leaflet or incomplete closure of the valve are more suitable for valve replacement. Echocardiography is the recognized investigation of choice for heart valve disease evaluation and assessment. However, the technique is depended on operator experience and on patient's hemodynamic profile, and may not always give optimal diagnostic views of mitral valve dysfunction. Cardiac catheterization is related to common complications of an interventional procedure and needs a hemodynamic laboratory. Cardiac magnetic resonance (MRI) seems to be a useful tool which gives details about mitral valve anatomy, precise point of valve damage, as well as the quantity of regurgitation. Finally, despite of its higher cost, cardiac MRI using cine images with optimized spatial and temporal resolution can also resolve mitral valve leaflet structural motion, and can reliably estimate the grade of regurgitation

    Choice of Valves — Homografts

    No full text

    Identification of the functional profilin gene, its localization to chromosome subband 17p13.3, and demonstration of its deletion in some patients with Miller-Dieker syndrome.

    No full text
    Profilin is a conserved actin-monomer-binding protein which is found in all eukaryotes, including yeast. Although amino acid sequence analysis and RNase protection analysis suggest a single profilin isoform in mammalian cells, Southern blot analysis of human and somatic cell hybrid DNA indicates several loci in the human genome which hybridize with the profilin cDNA. We therefore isolated human genomic clones to analyze these genetic loci in detail. Only one of the cloned loci has typical features of a functional gene, including upstream transcriptional elements and typical exon-intron structure. Four other isolated loci are all diverged, intronless pseudogenes and are likely to be nonfunctional. The functional gene was localized to human chromosome band 17p13 by analysis of somatic cell hybrids and by in situ chromosomal localization. The Miller-Dieker syndrome (MDS), a rare congenital disorder manifested by characteristic facial abnormalities and lissencephaly (smooth brain), is associated with microdeletions of the distal 17p region. RFLP analysis of a patient with MDS, and analysis of somatic cell hybrids containing partially deleted chromosomes 17 from patients with MDS, using the profilin gene probe, indicate that profilin is localized to chromosome subband 17p13.3. These results also indicate that profilin is the first identified cloned gene which is part of the genetic material deleted in some patients with MDS but that other patients have smaller deletions not affecting the profilin locus. Thus, single allelic deletion of the profilin locus may contribute to the clinical phenotype of the MDS in some patients but does not play a major role in the essential phenotype

    Cardiac positioning using an apical suction device maintains beating heart hemodynamics

    No full text
    Background: Cardiac positioning during off-pump coronary artery bypass (OPCAB) using deep pericardial sutures (DPS) typically results in some degree of hemodynamic compromise. We sought to determine whether cardiac positioning using an apical suction device was hemodynamically superior to DPS. Methods: Five healthy pigs underwent sternotomy and instrumentation to measure right atrial (RA) pressure, left ventricular (LV) pressure and volume, and aortic pressure and flow. These variables were recorded at baseline, with simple attachment of the apical suction device (Xpose™ Access Device, Guidant, Inc.), and during exposure of the posterior descending artery (PDA) and obtuse marginal (OM) branches of the left circumflex artery using DPS and the apical suction device. Results: Application of the apical suction device to the beating heart in neutral anatomic position did not result in any statistically significant change in hemodynamics compared to baseline except for a small decrease in RA pressure. DPS positioning resulted in statistically significant compromise in nearly all measured hemodynamic parameters, including cardiac output (-21% PDA, -30% OM), mean arterial pressure (-8% PDA, -26% OM), and stroke work (-31% PDA, -38% OM). In addition, LV end-diastolic pressure decreased (-59% PDA, -51% OM) while RA pressure increased (+17% PDA, +16% OM). Similar target exposure using the apical suction device resulted in near-baseline hemodynamics. The only statistically significant changes were a modest decrease in cardiac output (-18% OM) and RA pressure (-11% PDA). Conclusion: DPS positioning significantly compromises hemodynamics due to reduced LVfilling. The apical suction device provides good exposure with less hemodynamic compromise.link_to_subscribed_fulltex

    Right ventricular volume measurement using the conductance catheter method: Validation in excised porcine hearts

    No full text
    The conductance catheter method for measuring right ventricular (RV) volume changes was assessed in seven excised porcine hearts. A 5-FG conductance catheter was placed within a latex balloon and positioned in the RV cavity of seven freshly excised porcine hearts. Conductance was recorded while saline was withdrawn from the intraventricular balloon in 2 mi decrements. Linear regression analysis of measured conductance versus reference volumes was computed. The effect of left ventricular (LV) filling and catheter length on conductance derived RV volume was also determined. Conductance derived volumes were highly correlated with reference volumes [R 2 0.976, standard deviation (SD) 0.035]. The mean gradient of regression was 0.97 (SD 0.10), and it was not significantly affected by LV volume alterations. However, when we analyzed LV filling, a small but significant increase in the y-intercept was observed (LV empty 3.11 ml, SD 1.71; LV full 4.58, SD 2.39; p = 0.008). Introduction of the catheter through either the tricuspid or pulmonary orifices were both effective in ventricular volume measurement. The effect of mismatch between the catheter length and the RV long axis dimension was evaluated by changing the position of the active sensing electrodes along the catheter body. Conductance measurements, obtained from catheters shorter than the long axis of the RV, still maintained a highly linear correlation with real volume, but regression gradients were significantly reduced (long 0.975, SD 0.087; medium 0.787, SD 0.094; small 0.589, SD 0.091; p < 0.001). These results show that a conductance catheter of appropriate length can accurately measure RV volume, despite the complex shape and geometric changes associated with ventricular filling.link_to_subscribed_fulltex

    Minimally invasive direct access heart valve surgery

    No full text
    We review our experience with minimally invasive direct access (MIDA) heart valve surgery in 518 patients. Two hundred fifty-two patients underwent MIDA aortic valve replacement (AVR) or repair and 266 underwent MIDA mitral valve repair or replacement. Among the 250 AVRs, 157 (63%) were men, aged 63.2 ± 14.6 years, NYHA functional Class 2.4 ± 0.8. The surgical approach was right parasternal in 36 (14%) or upper hemisternotomy in 216 (86%). There were four (2%) operative deaths. Perioperative complications included 14 (5.6%) reexplorations for bleeding, 7 (3%) chest wound infections, 5 (2%) strokes, and 1 (0.4%) external iliac vein injury. Follow-up was complete in 193 (77%) patients, with a mean follow-up of 12 ± 8 months. Late complications included 2 (0.8%) nonfatal myocardial infarctions, 4 (2%) reoperations for, respectively, 2 pericardial complications, 1 paravalvar leak, and 1 infected valve. There were five (2%) late deaths from congestive heart failure, pneumonia, hemorrhage, aneurysm, and cancer. Mean follow-up NYHA Class was 1.4 ± 0.6. For the 266 mitral patients, 145 (54.5%) were men, age 58.7 ± 13.6 years, functional Class 2.3 ± 0.5. The surgical approach was right parasternal in 195 (73%), lower hemisternotomy in 53 (20%), right submammary thoracotomy in 9 (3.4%), or full sternotomy through a small skin incision in 9 (3.4%). There were 2 (0.8%) operative deaths. Perioperative complications included 4 (1.5%) reoperations for bleeding, 4 (1.5%) strokes, and 5 (2%) wound infections, and 3 (1%) ascending aortic complications. Follow-up was complete in 202 (76%) patients with a mean follow-up of 9.5 ± 6.4 months. Late complications included one (0.4%) nonfatal myocardial infarction and three (1%) reoperations all converting repairs to replacements. There were three (1%) late deaths from suicide, pneumonia, and sudden death, respectively. Mean follow-up NYHA functional Class was 1.3 ± 0.5. We conclude that MIDA heart valve surgery is safe and effective for the majority of patients requiring isolated elective aortic or mitral valve surgery.link_to_subscribed_fulltex

    Modified Glenn connection for acutely ischemic right ventricular failure reverses secondary left ventricular dysfunction

    Get PDF
    Background: Right heart failure after cardiopulmonary bypass can result in severe hemodynamic compromise with high mortality, but the underlying mechanisms remain poorly understood. After ischemia-induced right ventricular failure, alterations in the interventricular septal position decrease left ventricular compliance and limit filling but may also distort left ventricular geometry and compromise contractility and relaxation. This study investigated the effect of acute isolated right ventricular ischemia on biventricular performance and interaction and the response of subsequent right ventricular unloading by use of a modified Glenn shunt. Methods: In 8 pigs isolated right ventricular ischemic failure was induced by means of selective coronary ligation. A modified Glenn circuit was then established by a superior vena cava-pulmonary artery connection. Ventricular performance was determined by conductance catheter-derived right ventricular pressure-volume loops and left ventricular pressure-segment length loops. Hemodynamic data at baseline, after right ventricular ischemia, and after institution of the Glenn circuit were obtained during inflow occlusion, and the load-independent contractile indices were derived. Results: Right ventricular free-wall ischemia resulted in acute right ventricular dilation (118 ± 81 mL vs 169 ± 70 mL, P = .0008) and impairment of left ventricular contractility indicated by the reduced end-systolic pressure-volume relation slope (50.0 ± 19 mm Hg/mm vs 18.9 ± 8 mm Hg/mm, P = .002) and preload recruitable stroke work index slope (69.6 ± 26 erg · cm -3 · 10 3 vs 39.7 ± 13 erg · cm -3 · 10 3, P = .003). In addition, left ventricular relaxation (τ) was significantly prolonged (33.3 ± 10 ms vs 53.0 ± 16 ms, P = .012). Right ventricular unloading with the Glenn shunt reduced right ventricular dilation and significantly improved left ventricular contraction, end-systolic pressure-volume relation slope (18.9 ± 8 mm Hg/mm vs 35.8 ± 18 mm Hg/mm, P = .002), preload recruitable stroke work index slope (39.7 ± 26 erg · cm -3 · 10 3 vs 63.0 ± 22 erg · cm -3 · 10 3, P = .003), and diastolic performance (τ 53.0 ± 16 ms vs 43.5 ± 13 ms, P = .001). Conclusions: Right ventricular ischemia-induced dilation resulted in acute impairment of left ventricular contractility and relaxation. A modified Glenn shunt attenuated the left ventricular dysfunction by limiting right ventricular dilation and restoring left ventricular cavity geometry.link_to_subscribed_fulltex