46 research outputs found

    Electrical cardioversion during pregnancy: safe or not?

    Get PDF
    Two pregnant patients with a sustained symptomatic maternal supraventricular arrhythmia are presented. Both patients were treated with direct-current cardioversion. Electrical cardioversion during pregnancy is a rarely applied but highly effective procedure in the treatment of maternal cardiac arrhythmias and is assumed safe for both mother and child. However, once foetal viability is reached, monitoring of the foetal heart rate is advised and facilities for immediate caesarean section should be available

    1,25-Dihydroxyvitamin D3 modulates the phenotype and function of Monocyte derived dendritic cells in cattle

    Get PDF
    Abstract Background The active form of the vitamin D3, 1,25-Dihydroxyvitamin D3 (1,25-(OH)2D3) has been shown to have major effects not only on physiological processes but also on the regulation of the immune system of vertebrates. Dendritic cells are specialised antigen presenting cells which are in charge of the initiation of T-cell dependant immune responses and as such are key regulators of responses towards pathogens. In this study we set out to evaluate the effects of 1,25-(OH)2D3 on the phenotype of cattle monocyte-derived dendritic cells (MoDCs) and how the conditioning with this vitamin affects the function of these myeloid cells. Results MoDCs were generated from CD14+ monocytes with bovine IL-4 and GM-CSF with or without 1,25-(OH)2D3 supplementation for 10 days. Vitamin D conditioned MoDCs showed a reduced expression of co-stimulatory and antigen presenting molecules, as well as a reduced capability of endocytose ovalbumin. Furthermore, the capacity of MoDCs to induce proliferation in an allogeneic mixed leukocyte reaction was abolished when MoDCs were generated in presence of 1,25-(OH)2D3. LPS induced maturation of 1,25-(OH)2D3conditioned MoDCs resulted in lower secretion of IL-12 and higher IL-10 than that observed in MoDCs. Conclusions The typical immunotolerant phenotype observed in cattle DCs after exposure to 1,25-(OH)2D3 has a significant effect on the functionality of these immune cells, inhibiting the T-cell stimulatory capacity of MoDCs. This could have profound implications on how the bovine immune system deals with pathogens, particularly in diseases such as tuberculosis or paratuberculosis

    The relationship between high-frequency right ventricular pacing and paroxysmal atrial fibrillation burden

    No full text
    Right ventricular pacing increases the risk of persistent atrial fibrillation (AF) in the long term. The effects of right ventricular pacing on paroxysmal AF (PAF) are unknown. The aim was to examine the effect of right ventricular pacing on AF burden (AFB) in patients with symptomatic drug-resistant PAF. Pooled analysis of pacemaker-derived counters and AF diagnostic data from the Atrial Fibrillation Therapy (AFT) and Pacemaker Atrial Fibrillation Suppression (PAFS) randomized anti-AF pacemaker algorithm trials were used.Five hundred and fifty-four patients from the AFT (n = 372) and PAFS (n = 182) were studied. The individual percentages of pacing, Atrial Sense Ventricular Pace (ASVP), Atrial Pace Ventricular Pace (APVP), and Atrial Pace Ventricular Sense (APVS) as well as total ventricular pacing during synchronous rhythm (VPinSR, %) were examined for an effect on AFB. Three hundred and twenty-one (AFT, age 64 +/- 11, 55% male) and 79 (PAFS, age 71 +/- 8, 54% male) patients had complete data for analysis. Increased VPinSR was weakly associated with an increased AFB (effect size-10% VPinSR increased AFB by only 0.03%) in AFT (P = 0.04) but not PAFS (P = 0.98) or the pooled analysis (P = 0.95). None of the synchronous paced modalities (ASVP, APVP, APVS) significantly increased AFB compared with sinus rhythm (Atrial Sense Ventricular Sense) (P = ns).No pacing modality, atrial or ventricular, had a significant effect on AFB. On the basis of these data, the detrimental effect of high-frequency right ventricular pacing on AFB in paced PAF patients, unlike with persistent AF, appears to be minimal in the short term

    The safety and effectiveness of a nurse led cardioversion service under sedation

    No full text
    Objective: To assess the safety and effectiveness of nurse led elective cardioversion of atrial fibrillation under sedation. Design: Prospective, longitudinal study. Setting: Cardiac catheterisation laboratory and recovery area of a district general hospital. Patients: 300 patients referred for elective cardioversion of persistent atrial fibrillation. Interventions: Pre-procedure evaluations (history, physical examination, blood tests), consent, sedation administration, cardioversions, and post-procedure monitoring until discharge by advanced life support certified coronary care unit nurses trained in the techniques. A doctor was immediately available if required but not present. Main outcome measures: Success rates at discharge and at six weeks, energy delivered, number of shocks, dose of sedation, immediate, 24, and 48 hour patient perceptions, complications, waiting times, and cost effectiveness. Results: Cardioversion success rate was 87% at discharge and 48% at six weeks. Mean (SD) cumulative energy was 497 (282) J and number of shocks 1.6 (0.8). Mean (SD) dose of sedation was 23 (9) mg intravenous diazepam. No patient required reversal of sedation, airway support, or medical intervention. Ninety eight per cent of patients had no pain or recall of the procedure. Four patients who were adequately anticoagulated experienced embolic phenomena. Ninety eight per cent of patients would repeat the procedure if necessary. Without requirement for a physician or anaesthetist, waiting times for elective cardioversion fell from three months to under four weeks. There was a significant reduction in the estimated cost of the procedure from £337 with general anaesthesia to £130 with nurse led sedation and cardioversion (p < 0.001). Conclusion: With appropriate training, a nurse led cardioversion service with sedation is safe, effective, well tolerated, and cost efficient
    corecore