4,272 research outputs found
Applications of computer graphics to aircraft synthesis
The history of the development of an aircraft configuration synthesis program using interactive computer graphics was described. A system based on time-sharing was compared to two different concepts based on distributed computing
Development of a machine protection system for the Superconducting Beam Test Facility at Fermilab
Fermilab's Superconducting RF Beam Test Facility currently under construction
will produce electron beams capable of damaging the acceleration structures and
the beam line vacuum chambers in the event of an aberrant accelerator pulse.
The accelerator is being designed with the capability to operate with up to
3000 bunches per macro-pulse, 5Hz repetition rate and 1.5 GeV beam energy. It
will be able to sustain an average beam power of 72 KW at the bunch charge of
3.2 nC. Operation at full intensity will deposit enough energy in niobium
material to approach the melting point of 2500 {\deg}C. In the early phase with
only 3 cryomodules installed the facility will be capable of generating
electron beam energies of 810 MeV and an average beam power that approaches 40
KW. In either case a robust Machine Protection System (MPS) is required to
mitigate effects due to such large damage potentials. This paper will describe
the MPS system being developed, the system requirements and the controls issues
under consideration.Comment: 3 pp. 13th International Conference on Accelerator and Large
Experimental Physics Control Systems (ICALEPCS 2011). 10-14 Oct 2011.
Grenoble, Franc
Entangled and disentangled evolution for a single atom in a driven cavity
For an atom in an externally driven cavity, we show that special initial
states lead to near-disentangled atom-field evolution, and superpositions of
these can lead to near maximally-entangled states. Somewhat counterintutively,
we find that (moderate) spontaneous emission in this system actually leads to a
transient increase in entanglement beyond the steady-state value. We also show
that a particular field correlation function could be used, in an experimental
setting, to track the time evolution of this entanglement
Aerodynamic analysis of three advanced configurations using the TranAir full-potential code
Computational results are presented for three advanced configurations: the F-16A with wing tip missiles and under wing fuel tanks, the Oblique Wing Research Aircraft, and an Advanced Turboprop research model. These results were generated by the latest version of the TranAir full potential code, which solves for transonic flow over complex configurations. TranAir embeds a surface paneled geometry definition in a uniform rectangular flow field grid, thus avoiding the use of surface conforming grids, and decoupling the grid generation process from the definition of the configuration. The new version of the code locally refines the uniform grid near the surface of the geometry, based on local panel size and/or user input. This method distributes the flow field grid points much more efficiently than the previous version of the code, which solved for a grid that was uniform everywhere in the flow field. TranAir results are presented for the three configurations and are compared with wind tunnel data
Rollup subsolar array Quarterly technical report, 5 Mar. - 30 May 1969
Thermal cycling and environmental tests for solar arra
Measured Quantum Dynamics of a Trapped Ion
The measurement process is taken into account in the dynamics of trapped ions
prepared in nonclassical motional states. The induced decoherence is shown to
manifest itself both in the inhibition of the internal population dynamics and
in a damping of the vibrational motion without classical counterpart.
Quantitative comparison with present experimental capabilities is discussed,
leading to a proposal for the verification of the predicted effects.Comment: 5 Pages, no figures; Plain REVTeX; to be published in the 1st May
issue of Phys. Rev. A, Rap. Commun. (1997
Safety of localizing epilepsy monitoring intracranial electroencephalograph electrodes using MRI: radiofrequency-induced heating
Purpose:
To investigate heating during postimplantation localization of intracranial electroencephalograph (EEG) electrodes by MRI.
Materials and Methods:
A phantom patient with a realistic arrangement of electrodes was used to simulate tissue heating during MRI. Measurements were performed using 1.5 Tesla (T) and 3T MRI scanners, using head- and body-transmit RF-coils. Two electrode-lead configurations were assessed: a standard condition with external electrode-leads physically separated and a fault condition with all lead terminations electrically shorted.
Results:
Using a head-transmit-receive coil and a 2.4 W/kg head-average specific absorption rate (SAR) sequence, at 1.5T the maximum temperature change remained within safe limits (<1°C). Under standard conditions, we observed greater heating (2.0°C) at 3T on one system and similar heating (<1°C) on a second, compared with the 1.5T system. In all cases these temperature maxima occurred at the grid electrode. In the fault condition, larger temperature increases were observed at both field strengths, particularly for the depth electrodes. Conversely, with a body-transmit coil at 3T significant heating (+6.4°C) was observed (same sequence, 1.2/0.5 W/kg head/body-average) at the grid electrode under standard conditions, substantially exceeding safe limits. These temperature increases neglect perfusion, a major source of heat dissipation in vivo.
Conclusion:
MRI for intracranial electrode localization can be performed safely at both 1.5T and 3T provided a head-transmit coil is used, electrode leads are separated, and scanner-reported SARs are limited as determined in advance for specific scanner models, RF coils and implant arrangements. Neglecting these restrictions may result in tissue injury
Feasibility of simultaneous intracranial EEG-fMRI in humans: a safety study
In epilepsy patients who have electrodes implanted in their brains as part of their pre-surgical assessment, simultaneous intracranial EEG and fMRI (icEEG-fMRI) may provide important localising information and improve understanding of the underlying neuropathology. However, patient safety during icEEG-fMRI has not been addressed.
Here the potential health hazards associated with icEEG-fMRI were evaluated theoretically and the main risks identified as: mechanical forces on electrodes from transient magnetic effects, tissue heating due to interaction with the pulsed RF fields and tissue stimulation due to interactions with the switched magnetic gradient fields. These potential hazards were examined experimentally in vitro on a Siemens 3 T Trio, 1.5 T Avanto and a GE 3 T Signa Excite scanner using a Brain Products MR compatible EEG system.
No electrode flexion was observed. Temperature measurements demonstrated that heating well above guideline limits can occur. However heating could be kept within safe limits (< 1.0 °C) by using a head transmit RF coil, ensuring EEG cable placement to exit the RF coil along its central z-axis, using specific EEG cable lengths and limiting MRI sequence specific absorption rates (SARs). We found that the risk of tissue damage due to RF-induced heating is low provided implant and scanner specific SAR limits are observed with a safety margin used to account for uncertainties (e.g. in scanner-reported SAR). The observed scanner gradient switching induced current (0.08 mA) and charge density (0.2 μC/cm2) were well within safety limits (0.5 mA and 30 μC/cm2, respectively). Site-specific testing and a conservative approach to safety are required to avoid the risk of adverse events
Time evolution and squeezing of the field amplitude in cavity QED
We present the conditional time evolution of the electromagnetic field
produced by a cavity QED system in the strongly coupled regime. We obtain the
conditional evolution through a wave-particle correlation function that
measures the time evolution of the field after the detection of a photon. A
connection exists between this correlation function and the spectrum of
squeezing which permits the study of squeezed states in the time domain. We
calculate the spectrum of squeezing from the master equation for the reduced
density matrix using both the quantum regression theorem and quantum
trajectories. Our calculations not only show that spontaneous emission degrades
the squeezing signal, but they also point to the dynamical processes that cause
this degradation.Comment: 12 pages. Submitted to JOSA
Implementation and evaluation of simultaneous video-electroencephalography and functional magnetic resonance imaging
The objective of this study was to demonstrate that the addition of simultaneous and synchronised video to electroencephalography (EEG)-correlated functional magnetic resonance imaging (fMRI) could increase recorded information without data quality reduction. We investigated the effect of placing EEG, video equipment and their required power supplies inside the scanner room, on EEG, video and MRI data quality, and evaluated video-EEG-fMRI by modelling a hand motor task. Gradient-echo, echo-planner images (EPI) were acquired on a 3-T MRI scanner at variable camera positions in a test object [with and without radiofrequency (RF) excitation], and human subjects. EEG was recorded using a commercial MR-compatible 64-channel cap and amplifiers. Video recording was performed using a two-camera custom-made system with EEG synchronization. An in-house script was used to calculate signal to fluctuation noise ratio (SFNR) from EPI in test object with variable camera positions and in human subjects with and without concurrent video recording. Five subjects were investigated with video-EEG-fMRI while performing hand motor task. The fMRI time series data was analysed using statistical parametric mapping, by building block design general linear models which were paradigm prescribed and video based. Introduction of the cameras did not alter the SFNR significantly, nor did it show any signs of spike noise during RF off conditions. Video and EEG quality also did not show any significant artefact. The Statistical Parametric Mapping{T} maps from video based design revealed additional blood oxygen level-dependent responses in the expected locations for non-compliant subjects compared to the paradigm prescribed design. We conclude that video-EEG-fMRI set up can be implemented without affecting the data quality significantly and may provide valuable information on behaviour to enhance the analysis of fMRI data
- …