286 research outputs found

    Purification of Human Plasma/Cellular Fibronectin and Fibronectin Fragments

    Get PDF
    A method is described for the purification of plasma fibronectins based on a combination of gelatin- and arginine-Sepharose chromatography steps. Cellular fibronectin can be purified from an osteosarcoma fibroblast cell line by affinity chromatography using a monoclonal antibody anti-fibronectin as ligand. Furthermore, we also provide a protocol for the purification of fibronectin domains obtained by fractionation of thermolysin-digested plasma fibronectin on ion-exchange/gel filtration chromatography columns. Assessment of the fibronectin purity is performed by SDS-PAGE, while the ligand binding activities of specific fibronectin domains are determined by ELISA

    Portal Vein Embolization is Associated with Reduced Liver Failure and Mortality in High-Risk Resections for Perihilar Cholangiocarcinoma

    Get PDF
    Background Preoperative portal vein embolization (PVE) is frequently used to improve future liver remnant volume (FLRV) and to reduce the risk of liver failure after major liver resection. Objective This paper aimed to assess postoperative outcomes after PVE and resection for suspected perihilar cholangiocarcinoma (PHC) in an international, multicentric cohort. Methods Patients undergoing resection for suspected PHC across 20 centers worldwide, from the year 2000, were included. Liver failure, biliary leakage, and hemorrhage were classified according to the respective International Study Group of Liver Surgery criteria. Using propensity scoring, two equal cohorts were generated using matching parameters, i.e. age, sex, American Society of Anesthesiologists classification, jaundice, type of biliary drainage, baseline FLRV, resection type, and portal vein resection. Results A total of 1667 patients were treated for suspected PHC during the study period. In 298 patients who underwent preoperative PVE, the overall incidence of liver failure and 90-day mortality was 27% and 18%, respectively, as opposed to 14% and 12%, respectively, in patients without PVE (p < 0.001 and p = 0.005). After propensity score matching, 98 patients were enrolled in each cohort, resulting in similar baseline and operative characteristics. Liver failure was lower in the PVE group (8% vs. 36%, p < 0.001), as was biliary leakage (10% vs. 35%, p < 0.01), intra-abdominal abscesses (19% vs. 34%, p = 0.01), and 90-day mortality (7% vs. 18%, p = 0.03). Conclusion PVE before major liver resection for PHC is associated with a lower incidence of liver failure, biliary leakage, abscess formation, and mortality. These results demonstrate the importance of PVE as an integral component in the surgical treatment of PHC

    A large annotated medical image dataset for the development and evaluation of segmentation algorithms

    Get PDF
    Semantic segmentation of medical images aims to associate a pixel with a label in a medical image without human initialization. The success of semantic segmentation algorithms is contingent on the availability of high-quality imaging data with corresponding labels provided by experts. We sought to create a large collection of annotated medical image datasets of various clinically relevant anatomies available under open source license to facilitate the development of semantic segmentation algorithms. Such a resource would allow: 1) objective assessment of general-purpose segmentation methods through comprehensive benchmarking and 2) open and free access to medical image data for any researcher interested in the problem domain. Through a multi-institutional effort, we generated a large, curated dataset representative of several highly variable segmentation tasks that was used in a crowd-sourced challenge - the Medical Segmentation Decathlon held during the 2018 Medical Image Computing and Computer Aided Interventions Conference in Granada, Spain. Here, we describe these ten labeled image datasets so that these data may be effectively reused by the research community

    Use of a mixed tissue RNA design for performance assessments on multiple microarray formats

    Get PDF
    The comparability and reliability of data generated using microarray technology would be enhanced by use of a common set of standards that allow accuracy, reproducibility and dynamic range assessments on multiple formats. We designed and tested a complex biological reagent for performance measurements on three commercial oligonucleotide array formats that differ in probe design and signal measurement methodology. The reagent is a set of two mixtures with different proportions of RNA for each of four rat tissues (brain, liver, kidney and testes). The design provides four known ratio measurements of >200 reference probes, which were chosen for their tissue-selectivity, dynamic range coverage and alignment to the same exemplar transcript sequence across all three platforms. The data generated from testing three biological replicates of the reagent at eight laboratories on three array formats provides a benchmark set for both laboratory and data processing performance assessments. Close agreement with target ratios adjusted for sample complexity was achieved on all platforms and low variance was observed among platforms, replicates and sites. The mixed tissue design produces a reagent with known gene expression changes within a complex sample and can serve as a paradigm for performance standards for microarrays that target other species

    Comparison of risk-scoring systems in the prediction of outcome after liver resection

    Get PDF
    Background: Risk prediction techniques commonly used in liver surgery include the American Society of Anesthesiologists (ASA) grading, Charlson Comorbidity Index (CCI) and cardiopulmonary exercise tests (CPET). This study compares the utility of these techniques along with the number of segments resected as predictive tools in liver surgery. Methods: A review of a unit database of patients undergoing liver resection between February 2008 and January 2015 was undertaken. Patient demographics, ASA, CCI and CPET variables were recorded along with resection size. Clavien-Dindo grade III–V complications were used as a composite outcome in analyses. Association between predictive variables and outcome was assessed by univariate and multivariate techniques. Results: One hundred and seventy-two resections in 168 patients were identified. Grade III–V complications occurred after 42 (24.4%) liver resections. In univariate analysis of CPET variables, ventilatory equivalents for CO2 (VEqCO2) was associated with outcome. CCI score, but not ASA grade, was also associated with outcome. In multivariate analysis, the odds ratio of developing grade III–V complications for incremental increases in VEqCO2, CCI and number of liver segments resected were 1.09, 1.49 and 2.94, respectively. Conclusions: Of the techniques evaluated, resection size provides the simplest and most discriminating predictor of significant complications following liver surgery

    Liver surgery in the presence of cirrhosis or steatosis: Is morbidity increased?

    Get PDF
    <p>Abstract</p> <p>Background data</p> <p>The prevalence of steatosis and hepatitis-related liver cirrhosis is dramatically increasing together worldwide. Cirrhosis and, more recently, steatosis are recognized as a clinically important feature that influences patient morbidity and mortality after hepatic resection when compared with patients with healthy liver.</p> <p>Objective</p> <p>To review present knowledge regarding how the presence of cirrhosis or steatosis can influence postoperative outcome after liver resection.</p> <p>Methods</p> <p>A critical review of the English literature was performed to provide data concerning postoperative outcome of patients presenting injured livers who required hepatectomy.</p> <p>Results</p> <p>In clinical studies, the presence of steatosis impaired postoperative outcome regardless the severity and quality of the hepatic fat. A great improvement in postoperative outcome has been achieved using modern and multidisciplinary preoperative workup in cirrhotic patients. Due to the lack of a proper classification for morbidity and a clear definition of hepatic failure in the literature, the comparison between different studies is very limited. Although, many surgical strategies have been developed to protect injured liver surgery, no one have gained worldwide acceptance.</p> <p>Conclusion</p> <p>Surgeons should take the presence of underlying injured livers into account when planning the extent and type of hepatic surgery. Preoperative and perioperative interventions should be considered to minimize the additional damage. Further randomized trials should focus on the evaluation of novel preoperative strategies to minimize risk in these patients. Each referral liver center should have the commitment to report all deaths related to postoperative hepatic failure and to use a common classification system for postoperative complications.</p

    Safety of liver resection and effect on quality of life in patients with benign hepatic disease: Single center experience

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Although liver resection has long been established for selected patients with benign hepatic disease, the success of surgical treatment of these patients cannot be evaluated exclusively through postoperative morbidity and mortality. Therefore, the aim of the study was to prove the safety of liver resection in the treatment of benign liver tumors and to evaluate the effect of surgical treatment on the patients' qauality of life.</p> <p>Methods</p> <p>A total of 146 patients who underwent liver resection because of benign liver tumors were included in this study. Postoperative outcome was assessed and patients evaluated their quality of life before surgery and at the present time using the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire Core-30 (QLQ C-30).</p> <p>Results</p> <p>The rate of serious (> grade 2) complications was 4.1% with no postoperative death. The quality of life assessment revealed an overall improvement of general health status after resection (0.7 vs. 0.56, p < 0.001) and additionally a significant reduction of 6 out of 9 symptoms. Furthermore, compelling benefits in the patients' social and emotional coping could be detected after surgery.</p> <p>Conclusions</p> <p>Liver resection for benign liver disease is a safe procedure and leads to a significant improvement of quality of life in selected patients.</p

    Portal Vein Embolization is Associated with Reduced Liver Failure and Mortality in High-Risk Resections for Perihilar Cholangiocarcinoma

    Get PDF
    Background: Preoperative portal vein embolization (PVE) is frequently used to improve future liver remnant volume (FLRV) and to reduce the risk of liver failure after major liver resection. Objective: This paper aimed to assess postoperative outcomes after PVE and resection for suspected perihilar cholangiocarcinoma (PHC) in an international, multicentric cohort. Methods: Patients undergoing resection for suspected PHC across 20 centers worldwide, from the year 2000, were included. Liver failure, biliary leakage, and hemorrhage were classified according to the respective International Study Group of Liver Surgery criteria. Using propensity scoring, two equal cohorts were generated using matching parameters, i.e. age, sex, American Society of Anesthesiologists classification, jaundice, type of biliary drainage, baseline FLRV, resection type, and portal vein resection. Results: A total of 1667 patients were treated for suspected PHC during the study period. In 298 patients who underwent preoperative PVE, the overall incidence of liver failure and 90-day mortality was 27% and 18%, respectively, as opposed to 14% and 12%, respectively, in patients without PVE (p < 0.001 and p = 0.005). After propensity score matching, 98 patients were enrolled in each cohort, resulting in similar baseline and operative characteristics. Liver failure was lower in the PVE group (8% vs. 36%, p < 0.001), as was biliary leakage (10% vs. 35%, p < 0.01), intra-abdominal abscesses (19% vs. 34%, p = 0.01), and 90-day mortality (7% vs. 18%, p = 0.03). Conclusion: PVE before major liver resection for PHC is associated with a lower incidence of liver failure, biliary leakage, abscess formation, and mortality. These results demonstrate the importance of PVE as an integral component in the surgical treatment of PHC

    IVC CLAMP: infrahepatic inferior vena cava clamping during hepatectomy - a randomised controlled trial in an interdisciplinary setting

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Intraoperative haemorrhage is a known predictor for perioperative outcome of patients undergoing hepatic resection. While anaesthesiological lowering of central venous pressure (CVP) by fluid restriction is known to reduce bleeding during transection of the hepatic parenchyma its potential side effects remain poorly investigated. In theory it may have negative effects on kidney function and tissue perfusion and bears the risk to result in severe haemodynamic instability in case of profound intraoperative blood loss. The present randomised controlled trial evaluates efficacy and safety of infrahepatic inferior vena cava (IVC) clamping as an alternative surgical technique to reduce CVP during hepatic resection.</p> <p>Methods/Design</p> <p>The proposed IVC CLAMP trial is a single-centre randomised controlled trial with a two-group parallel design. Patients and outcome-assessors are blinded for the treatment intervention. Patients undergoing elective hepatic resection due to any reason are enrolled in IVC CLAMP. All patients admitted to the Department of General-, Visceral-, and Transplant Surgery, University of Heidelberg for elective hepatic resection are consecutively screened for eligibility and written informed consent is obtained on the day before surgery. The primary objective of this trial is to assess and compare the amount of blood loss during hepatic resection in patients receiving surgical CVP reduction by clamping of the IVC as compared to anaesthesiological CVP without infrahepatic IVC clamping reduction. In addition to blood loss a set of general as well as surgical variables are analysed.</p> <p>Discussion</p> <p>This is a randomised controlled patient and observer blinded two-group parallel trial designed to assess efficacy and safety of infrahepatic IVC clamping during elective hepatectomy.</p> <p>Trial registration</p> <p>ClinicalTrials NCT00732979</p
    corecore