1,125 research outputs found
Data user's notes of the radio astronomy experiment aboard the OGO-V spacecraft
General information concerning the low-frequency radiometer, instrument package launching and operation, and scientific objectives of the flight are provided. Calibration curves and correction factors, with general and detailed information on the preflight calibration procedure are included. The data acquisition methods and the format of the data reduction, both on 35 mm film and on incremental computer plots, are described
Pyroelectric detector arrays
A pyroelectric detector array and the method for using it are described. A series of holes formed through a silicon dioxide layer on the surface of a silicon substrate forms the mounting fixture for the pyroelectric detector array. A series of nontouching strips of indium are formed around the holes to make contact with the backside electrodes and form the output terminals for individual detectors. A pyroelectric detector strip with front and back electrodes, respectively, is mounted over the strips. Biasing resistors are formed on the surface of the silicon dioxide layer and connected to the strips. A metallized pad formed on the surface of layer is connected to each of the biasing resistors and to the film to provide the ground for the pyroelectric detector array
Magnetometer with miniature transducer and automatic transducer scanning apparatus
Magnetometer is simple to operate and has fast response. Transducer is rugged and flat and can measure magnetic fields as close as 0.08 mm from any relatively flat surface. Magnetometer has active region of approximately 0.64 by 0.76 mm and is capable of good spatial resolution of magnetic fields as low as 0.02 Oe (1.6 A/m)
A magnetic field measurement technique using a miniature transducer
The development, fabrication, and application of a magnetometer are described. The magnetometer has a miniature transducer and is capable of automatic scanning. The magnetometer described here is capable of detecting static magnetic fields as low as 1.6 A/m and its transducer has an active area 0.64 mm by 0.76 mm. Thin and rugged, the transducer uses wire, 0.05 mm in diameter, which is plated with a magnetic film, enabling measurement of transverse magnetic fields as close as 0.08 mm from a surface. The magnetometer, which is simple to operate and has a fast response, uses an inexpensive clip-on milliammeter (commonly found in most laboratories) for driving and processing the electrical signals and readout. A specially designed transducer holding mechanism replaces the XY recorder ink pen; this mechanism provides the basis for an automatic scanning technique. The instrument has been applied to the measurements of magnetic fields arising from remanent magnetization in experimental plated-wire memory planes and regions of magnetic activity in geological rock specimens
Application of the ERTS system to the study of Wyoming resources with emphasis on the use of basic data products
Many potential users of ERTS data products and other aircraft and satellite imagery are limited to visual methods of analyses of these products. Illustrations are presented from Wyoming studies that have employed these standard data products for a variety of geologic and related studies. Possible economic applications of these studies are summarized. Studies include regional geologic mapping for updating and correcting existing maps and to supplement incomplete regional mapping; illustrations of the value of seasonal images in geologic mapping; specialized mapping of such features as sand dunes, playa lakes, lineaments, glacial features, regional facies changes, and their possible economic value; and multilevel sensing as an aid in mineral exploration. Examples of cooperative studies involving botanists, plant scientists, and geologists for the preparation of maps of surface resources that can be used by planners and for environmental impact studies are given
Ariel - Volume 3 Number 5
Editors
Richard J. Bonanno
Robin A. Edwards
Associate Editors
Steven Ager
Tom Williams
Lay-out Editor
Eugenia Miller
Contributing Editors
Paul Bialas
Robert Breckenridge
Lynne Porter
David Jacoby
Terry Burt
Mark Pearlman
Michael Leo
Mike LeWitt
Editors Emeritus
Delvyn C. Case., Jr.
Paul M. Fernhof
Ariel - Volume 3 Number 7
Editors
Richard J. Bonanno
Robin A. Edwards
Associate Editors
Steven Ager
Tom Williams
Lay-out Editor
Eugenia Miller
Contributing Editors
Paul Bialas
Robert Breckenridge
David Jacoby
Mike LeWitt
Terry Burt
Michael Leo
Editors Emeritus
Delvyn C. Case, Jr.
Paul M. Fernhof
Recommended from our members
A Test of Incremental and All-or-None Theories of Acquisition by a Measure of Retention of Paired-Associate Learning
Recent research has found that subjects learning a list of paired-associates under conditions requiring one-trial learning are capable of learning a list of paired items in as few a number of trials as subject learning similar lists of paired-associates under a condition using repetition
- …