Characterisation of the mechanobiology of stents in vitro
This paper was presented at the 4th Micro and Nano Flows Conference (MNF2014), which was held at University College, London, UK. The conference was organised by Brunel University and supported by the Italian Union of Thermofluiddynamics, IPEM, the Process Intensification Network, the Institution of Mechanical Engineers, the Heat Transfer Society, HEXAG - the Heat Exchange Action Group, and the Energy Institute, ASME Press, LCN London Centre for Nanotechnology, UCL University College London, UCL Engineering, the International NanoScience Community, www.nanopaprika.eu.Long-term efficacy of percutaneous coronary intervention (PCI) to treat coronary heart disease is hampered by incidence of in-stent restenosis (ISR). The regrowth of a healthy endothelial layer post-treatment, a key factor in successful vascular repair, has been shown to be affected by the high sensitivity of endothelial cells (EC) to shear stress. Characterisation of stented artery haemodynamics is required to understand the response of EC to complex flow and shear stress patterns induced by stent structure. A device for the in vitro study of coronary stents has been developed and fabricated in polydimethylsiloxane (PDMS). Balloon-mounted cobalt-chromium stents have been successfully deployed, and particle tracking has been employed to obtain streamlines under low flow rate. High-resolution flow-patterns can be imaged, and complemented with in silico analysis from μCT data. The device allows for the seeding of EC, and sustained exposure to shear stress. EC response can be investigated by comparing real-time footage of cellular migration and proliferation to the haemodynamics of the specific region
Endothelial repair in stented arteries is accelerated by inhibition of Rho-associated protein kinase.
AIMS: Stent deployment causes endothelial cell (EC) denudation, which promotes in-stent restenosis and thrombosis. Thus endothelial regrowth in stented arteries is an important therapeutic goal. Stent struts modify local hemodynamics, however the effects of flow pertubation on EC injury and repair are incompletely understood. By studying the effects of stent struts on flow and EC migration we identified an intervention that promotes endothelial repair in stented arteries. METHODS AND RESULTS: In vitro and in vivo models were developed to monitor endothelialization under flow and the influence of stent struts. A 2D parallel-plate flow chamber with 100 μm ridges arranged perpendicular to the flow was used. Live cell imaging coupled to computational fluid dynamic simulations revealed that EC migrate in the direction of flow upstream from the ridges but subsequently accumulate downstream from ridges at sites of bidirectional flow. The mechanism of EC trapping by bidirectional flow involved reduced migratory polarity associated with altered actin dynamics. Inhibition of Rho-associated protein kinase (ROCK) enhanced endothelialization of ridged surfaces by promoting migratory polarity under bidirectional flow (p<0.01). To more closely mimic the in vivo situation we cultured EC on the inner surface of polydimethylsiloxane tubing containing Coroflex Blue stents (65 μm struts) and monitored migration. ROCK inhibition significantly enhanced EC accumulation downstream from struts under flow (p<0.05). We investigated the effects of ROCK inhibition on re-endothelialization in vivo using a porcine model of EC denudation and stent placement. En face staining and confocal microscopy revealed that inhibition of ROCK using fasudil (30 mg/day via osmotic minipump) significantly increased re-endothelialization of stented carotid arteries (p<0.05). CONCLUSIONS: Stent struts delay endothelial repair by generating localised bidirectional flow which traps migrating EC. ROCK inhibitors accelerate endothelial repair of stented arteries by enhancing EC polarity and migration through regions of bidirectional flow
Engineered Models of Metastasis with Application to Study Cancer Biomechanics
Three-dimensional complex biomechanical interactions occur from the initial steps of tumor formation to the later phases of cancer metastasis. Conventional monolayer cultures cannot recapitulate the complex microenvironment and chemical and mechanical cues that tumor cells experience during their metastatic journey, nor the complexity of their interactions with other, noncancerous cells. As alternative approaches, various engineered models have been developed to recapitulate specific features of each step of metastasis with tunable microenvironments to test a variety of mechanistic hypotheses. Here the main recent advances in the technologies that provide deeper insight into the process of cancer dissemination are discussed, with an emphasis on three-dimensional and mechanical factors as well as interactions between multiple cell types
Integrating particle tracking with computational fluid dynamics to assess haemodynamic perturbation by coronary artery stents
Aims
Coronary artery stents have profound effects on arterial function by altering fluid flow mass transport and wall shear stress. We developed a new integrated methodology to analyse the effects of stents on mass transport and shear stress to inform the design of haemodynamically-favourable stents.
Methods and results
Stents were deployed in model vessels followed by tracking of fluorescent particles under flow. Parallel analyses involved high-resolution micro-computed tomography scanning followed by computational fluid dynamics simulations to assess wall shear stress distribution. Several stent designs were analysed to assess whether the workflow was robust for diverse strut geometries. Stents had striking effects on fluid flow streamlines, flow separation or funnelling, and the accumulation of particles at areas of complex geometry that were tightly coupled to stent shape. CFD analysis revealed that stents had a major influence on wall shear stress magnitude, direction and distribution and this was highly sensitive to geometry.
Conclusions
Integration of particle tracking with CFD allows assessment of fluid flow and shear stress in stented arteries in unprecedented detail. Deleterious flow perturbations, such as accumulation of particles at struts and non-physiological shear stress, were highly sensitive to individual stent geometry. Novel designs for stents should be tested for mass transport and shear stress which are important effectors of vascular health and repair
Development of clinical prediction models for outcomes of complicated intra-abdominal infection.
Methods
A multicentre observational study was conducted from August 2016 to February 2017 in the UK. Adult patients diagnosed with cIAI were included. Multivariable logistic regression was performed to develop CPMs for mortality and cIAI relapse. The c-statistic was used to test model discrimination. Model calibration was tested using calibration slopes and calibration in the large (CITL). The CPMs were then presented as point scoring systems and validated further.
Results
Overall, 417 patients from 31 surgical centres were included in the analysis. At 90 days after diagnosis, 17.3 per cent had a cIAI relapse and the mortality rate was 11.3 per cent. Predictors in the mortality model were age, cIAI aetiology, presence of a perforated viscus and source control procedure. Predictors of cIAI relapse included the presence of collections, outcome of initial management, and duration of antibiotic treatment. The c-statistic adjusted for model optimism was 0.79 (95 per cent c.i. 0.75 to 0.87) and 0.74 (0.73 to 0.85) for mortality and cIAI relapse CPMs. Adjusted calibration slopes were 0.88 (95 per cent c.i. 0.76 to 0.90) for the mortality model and 0.91 (0.88 to 0.94) for the relapse model; CITL was −0.19 (95 per cent c.i. −0.39 to −0.12) and − 0.01 (− 0.17 to −0.03) respectively.
Conclusion
Relapse of infection and death after complicated intra-abdominal infections are common. Clinical prediction models were developed to identify patients at increased risk of relapse or death after treatment, although these require external validation