9,509 research outputs found
Infrared Observations of novae in the SOFIA era
Classical novae inject chemically enriched gas and dust into the local
inter-stellar medium (ISM). Abundances in the ejecta can be deduced from
infrared (IR) forbidden line emission. IR spectroscopy can determine the
mineralogy of grains that grow in nova ejecta. We anticipate the impact that
NASA's new Stratospheric Observatory for Infrared Astronomy (SOFIA) will have
on future IR studies of novae.Comment: To appear in the proceedings of "Physics of Evolved Stars 2015 - A
conference dedicated to the memory of Olivier Chesneau
The circumstellar dust of "Born-Again" stars
We describe the evolution of the carbon dust shells around Very Late Thermal
Pulse (VLTP) objects as seen at infrared wavelengths. This includes a 20-year
overview of the evolution of the dust around Sakurai's object (to which Olivier
made a seminal contribution) and FG Sge. VLTPs may occur during the endpoint of
as many as 25% of solar mass stars, and may therefore provide a glimpse of the
possible fate of the Sun.Comment: To appear in the proceedings of "Physics of Evolved Stars 2015 - A
conference dedicated to the memory of Olivier Chesneau
A comparison of minimum distance and maximum likelihood techniques for proportion estimation
The estimation of mixing proportions P sub 1, P sub 2,...P sub m in the mixture density f(x) = the sum of the series P sub i F sub i(X) with i = 1 to M is often encountered in agricultural remote sensing problems in which case the p sub i's usually represent crop proportions. In these remote sensing applications, component densities f sub i(x) have typically been assumed to be normally distributed, and parameter estimation has been accomplished using maximum likelihood (ML) techniques. Minimum distance (MD) estimation is examined as an alternative to ML where, in this investigation, both procedures are based upon normal components. Results indicate that ML techniques are superior to MD when component distributions actually are normal, while MD estimation provides better estimates than ML under symmetric departures from normality. When component distributions are not symmetric, however, it is seen that neither of these normal based techniques provides satisfactory results
The tail of the Jurassic fish Leedsichthys problematicus (Osteichthyes: Actinopterygii) collected by Alfred Nicholson Leeds - an example of the importance of historical records in palaeontology
The specimen of the tail of <i>Leedsichthys problematicus</i>, now in The Natural History Museum, London, was one of the most spectacular fossil vertebrates from the Oxford Clay Formation of Peterborough, but as an isolated find it shares no bones in common with the holotype of the genus and species. However, a letter from Alfred Nicholson Leeds and related documents cast valuable new light on the excavation of the tail, indicating that it was discovered with cranial bones, gill-rakers, and two pectoral fins, thereby including elements that can potentially be compared with those of the holotype. The documents also clearly indicate that The Natural History Museum's specimen is not part of the same individual as any other numbered specimen of <i>Leedsichthys</i> as had been speculated on other occasions. The maximum size of the animal represented by The Natural History Museum's specimen was possibly around 9 metres, considerably less than previous estimates of up to 27.6 metres for <i>Leedsichthys</i>. Historical documentary evidence should therefore be rigorously checked both when studying historical specimens in science, and in preparing text for museum display labels
Optimal Nitrogen Applications: A Stochastic Dynamic Model of Irrigated Corn in the Southern High Plains
Crop Production/Industries,
Effectiveness of an inlet flow turbulence control device to simulate flight noise fan in an anechoic chamber
A hemispherical inlet flow control device was tested on a 50.8 cm. (20-inch) diameter fan stage in the NASA-Lewis anechoic chamber. The control device used honeycomb and wire mesh to reduce turbulence intensities entering the fan. Far field acoustic power level results show about a 5 db reduction in blade passing tone and about 10 dB reduction in multiple pure tone sound power at 90% design fan speed with the inlet device in place. Hot film cross probes were inserted in the inlet to obtain data for two components of the turbulence at 65 and 90% design fan speed. Without the flow control device, the axial intensities were below 1.0%, while the circumferential intensities were almost twice this value. The inflow control device significantly reduced the circumferential turbulence intensities and also reduced the axial length scale
HB 239 - Business Courts
Georgia voters passed a constitutional amendment in November 2018, endorsing the establishment of a state-wide business court. The Act serves as the enabling legislation for the state-wide business court’s creation and implementation. Among other provisions, the Act provides the court’s location alternatives, jurisdictional limitations, filing fee, amount in controversy requirements, filing and transfer procedures, consent and objection rights for parties with cases and controversies slated for adjudication in state-wide business court, and minimum experience requirements for the presiding judge
Long-term storage and age‐biased export of fluvial organic carbon: field evidence from West Iceland
Terrestrial organic carbon (OC) plays an important role in the carbon cycle, but questions remain regarding the controls and timescale(s) over which atmospheric CO₂ remains sequestered as particulate OC (POC). Motivated by observations that terrestrial POC is physically stored within soils and other shallow sedimentary deposits, we examined the role that sediment storage plays in the terrestrial OC cycle. Specifically, we tested the hypothesis that sediment storage impacts the age of terrestrial POC. We focused on the Efri Haukadalsá River catchment in Iceland as it lacks ancient sedimentary bedrock that would otherwise bias radiocarbon‐based determinations of POC storage duration by supplying pre‐aged “petrogenic” POC.
Our radiocarbon measurements of riverine suspended sediments and deposits implicated millennial‐scale storage times. Comparison between the sample types (suspended and deposits) suggested an age offset between transported (suspended sediments) and stored (deposits) POC at the time of sampling, which is predicted by theory for the sediment age distribution in floodplains. We also observed that POC in suspended sediments is younger than the predicted mean storage duration generated from independent geomorphological data, which suggested an additional role for OC cycling. Consistent with this, we observed interparticle heterogeneity in the composition of POC by imaging our samples at the microscale using X‐ray absorption spectroscopy. Specifically, we found that particles within individual samples differed in their sulfur oxidation state, which is indicative of multiple origins and/or diagenetic histories. Altogether, our results support recent coupled sediment storage and OC cycling models and indicate that the physical drivers of sediment storage are important factors controlling the cadence of carbon cycling
Recommended from our members
Safe use of symbols in handover documentation for medical teams
Concern has been reported about the safe use of medical abbreviations in documents such as handover sheets and medical notes, especially when information is being communicated between staff of different specialties (BBC 2008, Sheppard et al. 2008). This article describes a study to investigate whether the use of symbols in handover documentation that is shared within and between multidisciplinary teams (MDTs) has similar safety implications. We asked 19 healthcare professionals from a range of specialties to identify 45 different combinations of 38 individual symbols. The symbols and combinations of symbols were extracted from 102 handover sheets taken from 6 different healthcare contexts in 4 London hospitals. Three symbols proposed in Microsoft's Common User Interface guidelines for alert symbols were also included. Results reveal that while some symbols are well understood, many others are either ambiguous or unknown. These results have implications for the safe use of symbols in medical documents, including paper and electronic handover documents and Electronic Patient Records (EPRs), especially where teams comprise individuals from different professional backgrounds, i.e. MDTs. We offer initial suggestions for standardisation and further research
- …