27 research outputs found

    A meta-analysis comparing the prognostic accuracy of six diagnostic tests for predicting perioperative cardiac risk in patients undergoing major vascular surgery

    Get PDF
    OBJECTIVE: To evaluate the discriminatory value and compare the predictive performance of six non-invasive tests used for perioperative cardiac risk stratification in patients undergoing major vascular surgery. DESIGN: Meta-analysis of published reports. METHODS: Eight studies on ambulatory electrocardiography, seven on exercise electrocardiography, eight on radionuclide ventriculography, 23 on myocardial perfusion scintigraphy, eight on dobutamine stress echocardiography, and four on dipyridamole stress echocardiography were selected, using a systematic review of published reports on preoperative non-invasive tests from the Medline database (January 1975 and April 2001). Random effects models were used to calculate weighted sensitivity and specificity from the published results. Summary receiver operating characteristic (SROC) curve analysis was used to evaluate and compare the prognostic accuracy of each test. The relative diagnostic odds ratio was used to study the differences in diagnostic performance of the tests. RESULTS: In all, 8119 patients participated in the studies selected. Dobutamine stress echocardiography had the highest weighted sensitivity of 85% (95% confidence interval (CI) 74% to 97%) and a reasonable specificity of 70% (95% CI 62% to 79%) for predicting perioperative cardiac death and non-fatal myocardial infarction. On SROC analysis, there was a trend for dobutamine stress echocardiography to perform better than the other tests, but this only reached significance against myocardial perfusion scintigraphy (relative diagnostic odds ratio 5.5, 95% CI 2.0 to 14.9). CONCLUSIONS: On meta-analysis of six non-invasive tests, dobutamine stress echocardiography showed a positive trend towards better diagnostic performance than the other tests, but this was only significant in the comparison with myocardial perfusion scintigraphy. However, dobutamine stress echocardiography may be the favoured test in situations where there is valvar or left ventricular dysfunction

    Cost-effectiveness of entecavir versus lamivudine for the suppression of viral replication in chronic hepatitis B Patients in Brazil

    No full text
    Hepatitis B virus infection is an important public-health issue. Chronic patients have a higher risk of death due to complications, which increases health-care expenses in. Cost-effectiveness analysis of entecavir (ETV) versus lamivudine (LVD) for treatment of chronic hepatitis B, in e antigen (AgHBe)-positive and negative patients, based on two phase 3, controlled and randomized studies. A decision analysis model was developed, using the following endpoints: cost per patient with undetectable viral load and cost per quality life year (QALY) gained. Risks for complications (compensated or decompensated cirrhosis and hepatocellular carcinoma) were based on the cohort study REVEAL, published in 2006. The REVEAL parameters were applied to the results of the viral load levels obtained from the clinical assay data. The complication costs were based on a study of the disease cost conducted in Brazil, in 2005. The cost data were obtained predominantly from Sistema Único de Saúde [SUS - Brazilian public health system] payment tables and drug price lists. The utility data were obtained from literature and life expectancy information was based on IBGE data. The analysis perspective was that of SUS. A discount rate of 3% per year was used. For the horizon of time of 10 years, the ETV had an incremental cost of approximately two million Brazilian Reais (R$) compared to LVD. Reducing the number of complications, ETV treatment reduced costs by around 3 million, reducing final costs by 1 million, for AgHBe-positive patients. ETV also reduced the incremental cost per QALY gained. ETV was found to be the most cost-effective alternative for AgHBe-positive and negative patients

    Patterns of viral load in chronic hepatitis B patients in Brazil and their association with ALT levels and HBeAg status

    No full text
    Serum hepatitis B virus (HBV) DNA [eve[ is a predictor of the development of cirrhosis and hepatocellullar carcinoma in chronic hepatitis B patients. Nevertheless, the distribution of viral load levels in chronic HBV patients in Brazil has yet to be described. This cross-sectional study included 564 participants selected in nine Brazilian cities located in four of the five regions of the country using the database of a medical diagnostics company. Admission criteria included hepatitis B surface antigen seropositivity, availability of HBV viral toad samples and age >= 18 years. Mates comprised 64.5% of the study population. Mean age was 43.7 years. Most individuals (62.1%) were seronegative for the hepatitis B e antigen (HBeAg). Median serum ALT level was 34 U/L. In 58.5% of the patients HBV-DNA levels ranged from 300 to 99,999 copies/mL; however, in 21.6% levels were undetectable. Median HBV-DNA level was 2,351 copies/mL. Over 60% of the patients who tested negative for HBeAg and in whom ALT level was less than 1.5 times the upper limit of the normal range had HBV-DNA levels > 2,000 IU/mL, which has been considered a cut-off point for indicating a liver biopsy and/or treatment. In conclusion, HBV-DNA level identified a significant proportion of Brazilian individuals with chronic hepatitis B at risk of disease progression. Furthermore, this tool. enables those individuals with high HBV-DNA levels who are susceptible to disease progression to be identified among patients with normal or stightly elevated ALT.Bristol-Myers Squibb, Co

    Orthogonal HPLC methods for quantitating related substances and degradation products of pramlintide

    No full text
    Pramlintide is a 37-amino acid peptide that is being evaluated as a drug candidate for treating people with type 1 and insulin-using type 2 diabetes. Two high-performance liquid chromatography (HPLC) methods were developed for quantitating related substance impurities in pramlintide drug substance as well as degradation products of pramlintide formulated for parenteral administration. The methods differ with respect to separation mode and therefore provide orthogonal information concerning related substances and degradation products. One method uses a reverse phase (RP) separation mode, and the other involves a strong cation exchange (SCX) separation. Method performance testing showed that the RP- and SCX-HPLC methods both afford a high degree of selectivity, accuracy, precision, and sensitivity. The limit of quantitation for determining spiked authentic samples of degradation products was shown to be approximately 0.1% (relative to intact pramlintide) for both methods. Relative retention times for known pramlintide degradation products were determined for both the RP- and SCX-HPLC methods, demonstrating the selectivities of the 2 methods as well as the orthogonality of the information. The methods were also shown to be diastereospecific with respect to separating pramlintide from authentic samples of D-isomers at Ala5, Ala8, Ala5-Ala8, and Leu12. The methods did not resolve pramlintide, however, from diastereomers with D-isomers near the C- and N-termini, namely Lys1,Cys2, and Tyr37
    corecore