1,556 research outputs found
Expanding the use of real-time electromagnetic tracking in radiation oncology.
In the past 10 years, techniques to improve radiotherapy delivery, such as intensity-modulated radiation therapy (IMRT), image-guided radiation therapy (IGRT) for both inter- and intrafraction tumor localization, and hypofractionated delivery techniques such as stereotactic body radiation therapy (SBRT), have evolved tremendously. This review article focuses on only one part of that evolution, electromagnetic tracking in radiation therapy. Electromagnetic tracking is still a growing technology in radiation oncology and, as such, the clinical applications are limited, the expense is high, and the reimbursement is insufficient to cover these costs. At the same time, current experience with electromagnetic tracking applied to various clinical tumor sites indicates that the potential benefits of electromagnetic tracking could be significant for patients receiving radiation therapy. Daily use of these tracking systems is minimally invasive and delivers no additional ionizing radiation to the patient, and these systems can provide explicit tumor motion data. Although there are a number of technical and fiscal issues that need to be addressed, electromagnetic tracking systems are expected to play a continued role in improving the precision of radiation delivery
Quantifying the ki-67 heterogeneity profile in prostate cancer.
BackgroundKi-67 is a robust predictive/prognostic marker in prostate cancer; however, tumor heterogeneity in prostate biopsy samples is not well studied.MethodsUsing an MRI/US fusion device, biopsy cores were obtained systematically and by targeting when indicated by MRI. Prostate cores containing cancer from 77 consecutive men were analyzed. The highest Ki-67 was used to determine interprostatic variation. Ki-67 range (highest minus lowest) was used to determine intraprostatic and intralesion variation. Apparent diffusion coefficient (ADC) values were evaluated in relation to Ki-67.ResultsInterprostatic Ki-67 mean ± standard deviation (SD) values for NCCN low (L), intermediate (I), and high (H) risk patients were 5.1 ± 3.8%, 7.4 ± 6.8%, and 12.0 ± 12.4% (ANOVA P = 0.013). Intraprostatic mean ± SD Ki-67 ranges in L, I, and H risk patients were 2.6 ± 3.6%, 5.3 ± 6.8%, and 10.9 ± 12.3% (ANOVA P = 0.027). Intralesion mean ± SD Ki-67 ranges in L, I, and H risk patients were 1.1 ± 0.9%, 5.2 ± 7.9%, and 8.1 ± 10.8% (ANOVA P = 0.22). ADC values at Ki-67 > and <7.1% were 860 ± 203 and 1036 ± 217, respectively (P = 0.0029).ConclusionsHigh risk patients have significantly higher inter- and intraprostatic Ki-67 heterogeneity. This needs to be considered when utilizing Ki-67 clinically
Recommended from our members
Comparison of transabdominal ultrasound and electromagnetic transponders for prostate localization.
The aim of this study is to compare two methodologies of prostate localization in a large cohort of patients. Daily prostate localization using B-mode ultrasound has been performed at the Nebraska Medical Center since 2000. More recently, a technology using electromagnetic transponders implanted within the prostate was introduced into our clinic (Calypso(R)). With each technology, patients were localized initially using skin marks. Localization error distributions were determined from offsets between the initial setup positions and those determined by ultrasound or Calypso. Ultrasound localization data was summarized from 16619 imaging sessions spanning 7 years; Calypso localization data consists of 1524 fractions in 41 prostate patients treated in the course of a clinical trial at five institutions and 640 localizations from the first 16 patients treated with our clinical system. Ultrasound and Calypso patients treated between March and September 2007 at the Nebraska Medical Center were analyzed and compared, allowing a single institutional comparison of the two technologies. In this group of patients, the isocenter determined by ultrasound-based localization is on average 5.3 mm posterior to that determined by Calypso, while the systematic and random errors and PTV margins calculated from the ultrasound localizations were 3 - 4 times smaller than those calculated from the Calypso localizations. Our study finds that there are systematic differences between Calypso and ultrasound for prostate localization
The role of chronic and recurrent infection in the generation of overactive bladder symptoms in multiple sclerosis
This thesis provides original evidence that patients with multiple sclerosis may harbour undisclosed urinary infection that generates urothelial inflammation and overactive bladder symptoms. The studies within this thesis examine the performance of recommended diagnostic tests for urinary tract infection, and explore the bacterial ecology of urinary infection and its associated urothelial inflammatory response. The association between lower urinary tract inflammation, bacterial colonisation and the generation of overactive bladder symptoms is explored. A novel therapy with proposed immunomodulatory effects was tested as a candidate treatment for overactive bladder symptoms. The urinary dipstick is the recommended diagnostic test for urinary infection in patients with multiple sclerosis. In patients with chronic lower urinary tract symptoms, the dipstick failed to identify culture-positive bacterial infection in more than half of cases. This failure is compounded by the poor performance of current culture-based diagnosis that employs erroneous quantitative diagnostic thresholds. When a sensitive culture method was deployed and quantitative thresholds rejected, controlled data demonstrated that bacterial urinary infection was evident in sixty percent of patients. Quantitative and qualitative differences in the bacterial ecology of infecting isolates were evident amongst patients and controls. This was associated with increased urothelial inflammation amongst patients. Prospective, controlled data demonstrated that escalating urothelial inflammation, characterised by the expression of pyuria, was associated with increased bacterial load in the lower urinary tract. Pyuria predicted the severity of overactive bladder symptoms and indices of bladder function. Am immunomodulatory treatment for overactive bladder symptoms was tested as part of this work but no therapeutic effects were identified
Urinary ATP as an indicator of infection and inflammation of the urinary tract in patients with lower urinary tract symptoms
BACKGROUND:
Adenosine-5'-triphosphate (ATP) is a neurotransmitter and inflammatory cytokine implicated in the pathophysiology of lower urinary tract disease. ATP additionally reflects microbial biomass thus has potential as a surrogate marker of urinary tract infection (UTI). The optimum clinical sampling method for ATP urinalysis has not been established. We tested the potential of urinary ATP in the assessment of lower urinary tract symptoms, infection and inflammation, and validated sampling methods for clinical practice.
METHODS:
A prospective, blinded, cross-sectional observational study of adult patients presenting with lower urinary tract symptoms (LUTS) and asymptomatic controls, was conducted between October 2009 and October 2012. Urinary ATP was assayed by a luciferin-luciferase method, pyuria counted by microscopy of fresh unspun urine and symptoms assessed using validated questionnaires. The sample collection, storage and processing methods were also validated.
RESULTS:
75 controls and 340 patients with LUTS were grouped as without pyuria (n = 100), pyuria 1-9 wbc ?l(-1) (n = 120) and pyuria ?10 wbc ?l(-1) (n = 120). Urinary ATP was higher in association with female gender, voiding symptoms, pyuria greater than 10 wbc ?l(-1) and negative MSU culture. ROC curve analysis showed no evidence of diagnostic test potential. The urinary ATP signal decayed with storage at 23°C but was prevented by immediate freezing at ??-20°C, without boric acid preservative and without the need to centrifuge urine prior to freezing.
CONCLUSIONS:
Urinary ATP may have a role as a research tool but is unconvincing as a surrogate, clinical diagnostic marker
Neonatal exposure to monosodium glutamate results in dysmorphology of orofacial lower motor neurons
Glutamate is the most abundant excitatory neurotransmitter in the central nervous system, and is stored and released by both neurons and astrocytes. Despite the important role of glutamate as a neurotransmitter, high levels of extracellular glutamate can result in excitotoxicity and apoptosis. Monosodium glutamate (MSG) is a naturally occurring sodium salt of glutamic acid that is used as a flavour enhancer in many processed foods. Neonatal exposure to MSG has been shown to result in neurodegeneration in several forebrain regions, characterised by neuronal loss and neuroendocrine abnormalities. However, the brainstem effects of neonatal MSG exposure have not been investigated. It is therefore hypothesized that MSG exposure during the early postnatal period would impact brainstem lower motor neurons involved in feeding behaviour. The effect of neonatal MSG exposure on brainstem lower motor neurons was investigated by exposing rat pups to either 4 mg/g MSG or saline from postnatal day (P) 4 through 10. On P28, brains were preserved by vascular perfusion with fixative, frozen sectioned and stained for NĂŻssl substance. The number, size and shape of brainstem motor neurons were compared between MSG and saline-exposed animals. MSG exposure had no impact on the total number of neurons in the nuclei examined. However, MSG exposure was associated with a significant increase in the number of round somata in both the trigeminal and facial nuclei. Furthermore, MSG exposure resulted in significantly smaller neurons in all motor nuclei examined. These results suggest that neonatal exposure to MSG impacts the development of brainstem lower motor neurons which may impact feeding and swallowing behaviours in young animals.
Recommended from our members
Modeling Real-Time 3-D Lung Deformations for Medical Visualization
In this paper, we propose a physics-based and physiology-based approach for modeling real-time deformations of 3-D high-resolution polygonal lung models obtained from high-resolution computed tomography (HRCT) images of normal human subjects. The physics-based deformation operator is nonsymmetric, which accounts for the heterogeneous elastic properties of the lung tissue and spatial-dynamic flow properties of the air. An iterative approach is used to estimate the deformation with the deformation operator initialized based on the regional alveolar expandability, a key physiology-based parameter. The force applied on each surface node is based on the airflow pattern inside the lungs, which is known to be based on the orientation of the human subject. The validation of lung dynamics is done by resimulating the lung deformation and comparing it with HRCT data and computing force applied on each node derived from a 4-D HRCT dataset of a normal human subject using the proposed deformation operator and verifying its gradient with the orientation
Lower urinary tract symptoms that predict microscopic pyuria
INTRODUCTION AND HYPOTHESIS: Urinary dipsticks and culture analyses of a mid-stream urine specimen (MSU) at 10(5) cfu ml(-1) of a known urinary pathogen are considered the gold standard investigations for diagnosing urinary tract infection (UTI). However, the reliability of these tests has been much criticised and they may mislead. It is now widely accepted that pyuria (≥1 WBC μl(-1)) detected by microscopy of a fresh unspun, unstained specimen of urine is the best biological indicator of UTI available. We aimed to scrutinise the greater potential of symptoms analysis in detecting pyuria and UTI. METHODS: Lower urinary tract symptom (LUTS) descriptions were collected from patients with chronic lower urinary tract symptoms referred to a tertiary referral unit. The symptoms informed a 39-question inventory, grouped into storage, voiding, stress incontinence and pain symptoms. All questions sought a binary yes or no response. A bespoke software package was developed to collect the data. The study was powered to a sample of at least 1,990 patients, with sufficient power to analyse 39 symptoms in a linear model with an effect size of Cohen's f(2) = 0.02, type 1 error probability = 0.05; and power (1-β); 95% where β is the probability of type 2 error). The inventory was administered to 2,050 female patients between August 2004 and November 2011. The data were collated and the following properties assessed: internal consistency, test-retest reliability, inter-observer reliability, internal responsiveness, external responsiveness, construct validity analysis and a comparison with the International Consultation on Incontinence Modular Questionnaire for female lower urinary tract symptoms (ICIQ-FLUTS). The dependent variable used as a surrogate marker of UTI was microscopic pyuria. An MSU sample was sent for routine culture. RESULTS: The symptoms proved reliable predictors of microscopic pyuria. In particular, voiding symptoms correlated well with microscopic pyuria (χ(2) = 88, df = 1, p < 0.001). The symptom inventory has significant psychometric characteristics as below: test-retest reliability: Cronbach's alpha was 0.981; inter-observer reliability, Cronbach's alpha was 0.995, internal responsiveness F = 221, p < 0.001, external responsiveness F = 359, df = 5, p < 0.001. The correlation coefficients for the domains of the ICIQ-FLUTS were around R = 0.5, p < 0.001. CONCLUSION: This symptoms score performed well on the standard, psychometric validation. The score changed in response to treatment and in a direction appropriate to the changes in microscopic pyuria. It correlated with measures of quality of life. It would seem to make a good candidate for monitoring treatment progress in ordinary clinical practice
Safety and efficacy of non-absorbable mesh in contemporary gynaecological surgery
Mesh-augmented pelvic floor surgery evolved to address the limitations of native tissue repair in reconstructive surgery. The development of the synthetic mid-urethral tape signalled a revolution in the treatment of stress urinary incontinence, whilst the use of mesh in abdominal apical prolapse repair may confer benefits over native tissue alternatives. However, these procedures can be associated with mesh-specific complications, underlining the need for shared decision-making between physicians and patients prior to mesh surgery.
Transvaginal non-absorbable mesh implants for pelvic organ prolapse are associated with a high risk of serious adverse events, leading to withdrawal or restricted use in many countries. Increased scrutiny has led to growing concerns about complications associated with all types of mesh-augmented reconstructive surgery, attracting widespread media attention.
National and international reports have been commissioned examining the safety and efficacy of mesh surgery in gynaecology. They have all highlighted systemic failures in the development, regulation and clinical adoption of medical devices. The widespread application of novel devices prior to the availability of reliable safety and efficacy data, and delayed recognition of adverse events, is of serious concern. Notwithstanding, the available data continue to support a role for mesh augmentation. This review outlines the evolution of gynaecological mesh, the safety and efficacy of pelvic floor surgery using non-absorbable mesh materials, and an overview of specific complications
Health-Related Quality of Life After Stereotactic Body Radiation Therapy for Localized Prostate Cancer: Results From a Multi-institutional Consortium of Prospective Trials
PurposeTo evaluate the early and late health-related quality of life (QOL) outcomes among prostate cancer patients following stereotactic body radiation therapy (SBRT).Methods and MaterialsPatient self-reported QOL was prospectively measured among 864 patients from phase 2 clinical trials of SBRT for localized prostate cancer. Data from the Expanded Prostate Cancer Index Composite (EPIC) instrument were obtained at baseline and at regular intervals up to 6 years. SBRT delivered a median dose of 36.25 Gy in 4 or 5 fractions. A short course of androgen deprivation therapy was given to 14% of patients.ResultsMedian follow-up was 3 years and 194 patients remained evaluable at 5 years. A transient decline in the urinary and bowel domains was observed within the first 3 months after SBRT which returned to baseline status or better within 6 months and remained so beyond 5 years. The same pattern was observed among patients with good versus poor baseline function and was independent of the degree of early toxicities. Sexual QOL decline was predominantly observed within the first 9 months, a pattern not altered by the use of androgen deprivation therapy or patient age.ConclusionLong-term outcome demonstrates that prostate SBRT is well tolerated and has little lasting impact on health-related QOL. A transient and modest decline in urinary and bowel QOL during the first few months after SBRT quickly recovers to baseline levels. With a large number of patients evaluable up to 5 years following SBRT, it is unlikely that unexpected late adverse effects will manifest themselves
- …