7 research outputs found

    Inadequate Loading Stimulus on ISS Results in Bone and Muscle Loss

    Get PDF
    INTRODUCTION Exercise has been the primary countermeasure to combat musculoskeletal changes during International Space Station (ISS) missions. However, these countermeasures have not been successful in preventing loss of bone mineral density (BMD) or muscle volume in crew members. METHODS We examined lower extremity loading during typical days on-orbit and on Earth for four ISS crew members. In-shoe forces were monitored using force-measuring insoles placed inside the shoes. BMD (by DXA), muscle volumes (by MRI), and strength were measured before and after long-duration spaceflight (181 +/- 15 days). RESULTS The peak forces measured during ISS activity were significantly less than those measured in 1g for the same activities. Typical single-leg loads on-orbit during walking and running were 0.89 +/- 0.17 body weights (BW) and 1.28 +/- 0.18 BW compared to 1.18 +/- 0.11 BW and 2.36 +/- .22 BW in 1g, respectively [2]. Crew members were only loaded for an average of 43.17 +/- 14.96 min a day while performing exercise on-orbit even though 146.8 min were assigned for exercise each day. Areal BMD decreased in the femoral neck and total hip by 0.71 +/- 0.34% and 0.81 +/- 0.21% per month, respectively. Changes in muscle volume were observed in the lower extremity (-10 to -16% calf; -4 to -7% thigh) but there were no changes in the upper extremity (+0.4 to -0.8%). Decrements in isometric and isokinetic strength at the knee (range: -10.4 to -24.1%), ankle (range: -4 to -22.3%), and elbow (range: -7.5 to - 16.7%) were also observed. Knee extension endurance tests showed an overall decline in total work (-14%) but an increased resistance to fatigue post-flight. DISCUSSION AND CONCLUSIONS Our findings support the conclusion that the measured exercise durations and/or loading stimuli were insufficient to protect bone and muscle health

    Foot Reaction Forces during Long Duration Space Flight

    Get PDF
    Musculoskeletal changes, particularly in the lower extremities, are an established consequence of long-duration space flight despite exercise countermeasures. It is widely believed that disuse and reduction in load bearing are key to these physiological changes, but no quantitative data characterizing the on-orbit movement environments currently exist. Here we present data from the Foot Experiment (E318) regarding astronaut activity on the ground and on-orbit during typical days from 4 International Space Station (ISS) crew members who flew during increments 6, 8, 11, and 12

    Using the Enhanced Daily Load Stimulus Model to Quantify the Mechanical Load and Bone Mineral Density Changes Experienced by Crew Members on the International Space Station

    Get PDF
    Despite the use of exercise countermeasures during long-duration space missions, bone mineral density (BMD) and predicted bone strength of astronauts continue to show decreases in the lower extremities and spine. This site-specific bone adaptation is most likely caused by the effects of microgravity on the mechanical loading environment of the crew member. There is, therefore, a need to quantify the mechanical loading experienced on Earth and on-orbit to define the effect of a given "dose" of loading on bone homeostasis. Gene et al. recently proposed an enhanced DLS (EDLS) model that, when used with entire days of in-shoe forces, takes into account recently developed theories on the importance of factors such as saturation, recovery, and standing and their effects on the osteogenic response of bone to daily physical activity. This algorithm can also quantify the tinting and type of activity (sit/unload, stand, walk, run or other loaded activity) performed throughout the day. The purpose of the current study was to use in-shoe force measurements from entire typical work days on Earth and on-orbit in order to quantify the type and amount of loading experienced by crew members. The specific aim was to use these measurements as inputs into the EDLS model to determine activity timing/type and the mechanical "dose" imparted on the musculoskeletal system of crew members and relate this dose to changes in bone homeostasis

    Broadband all-optical plane-wave ultrasound imaging system based on a Fabry-Perot scanner

    No full text
    A broadband all-optical plane-wave ultrasound imaging system for high-resolution 3D imaging of biological tissues is presented. The system is based on the planar Fabry-Perot (FP) scanner for ultrasound detection and the photoacoustic generation of ultrasound in a Carbon-Nanotube-Polydimethylsiloxane (CNT-PDMS) composite film. The FP sensor head was coated with the CNT-PDMS film to act as an ultrasound transmitting layer for pulse-echo imaging. Exciting the CNT-PDMS coating with nanosecond laser pulses generated monopolar plane-wave ultrasound pulses with MPa-range peak pressures, and a -6dB bandwidth of 22 MHz, that were transmitted into the target. The resulting scattered acoustic field was detected across a 15 mm × 15 mm scan area with a step size of 100 μm and an optically defined element size of 64 μm. The -3dB bandwidth of the sensor was 30 MHz. A 3D image of the scatterer distribution was then recovered using a k-space reconstruction algorithm. To obtain a measure of spatial resolution, the instrument line-spread function (LSF) was measured as a function of position. At the centre of the scan area the depth dependent lateral LSF ranged from 46 to 65 μm for depths between 1 and 12 mm. The vertical LSF was independent of position and measured to be 44 μm over the entire field of view. To demonstrate the ability of the system to provide high-resolution 3D images, phantoms with well-defined scattering structures of arbitrary geometry were imaged. To demonstrate its suitability for imaging biological tissues, phantoms with similar impedance mismatches, sound speed and scattering properties to those present in tissue, and ex-vivo tissue samples were imaged. Compared to conventional piezoelectric based ultrasound scanners this approach offers the potential for improved image quality and higher resolution for superficial tissue imaging. Since the FP scanner is capable of high-resolution 3D photoacoustic imaging of in-vivo biological tissues, the system could ultimately be developed into an instrument for dual-mode all-optical ultrasound and photoacoustic imaging
    corecore