209 research outputs found

    On the accuracy of retrieved wind information from Doppler lidar observations

    Get PDF
    A single pulsed Doppler lidar was successfully deployed to measure air flow and turbulence over the Malvern hills, Worcester, UK. The DERA Malvern lidar used was a CO2 µm pulsed Doppler lidar. The lidar pulse repetition rate was 120 Hz and had a pulse duration of 0.6 µs The system was set up to have 41 range gates with range resolution of 112 m. This gave a theoretical maximum range of approximately 4.6 km. The lidar site was 2 km east of the Malvern hill ridge which runs in a north-south direction and is approximately 6 km long. The maximum height of the ridge is 430 m. Two elevation scans (Range-Height Indicators) were carried out parallel and perpendicular to the mean surface flow. Since the surface wind was primarily westerly the scans were carried out perpendicular and parallel to the ridge of the Malvern hills. The data were analysed and horizontal winds, vertical winds and turbulent fluxes were calculated for profiles throughout the boundary layer. As an aid to evaluating the errors associated with the derivation of velocity and turbulence profiles, data from a simple idealized profile was also analysed using the same method. The error analysis shows that wind velocity profiles can be derived to an accuracy of 0.24 m s-1 in the horizontal and 0.3 m s-1 in the vertical up to a height of 2500 m. The potential for lidars to make turbulence measurements, over a wide area, through the whole depth of the planetary boundary layer and over durations from seconds to hours is discussed

    Plume motion and large-scale circulation in a cylindrical Rayleigh-B\'enard cell

    Full text link
    We used the time correlation of shadowgraph images to determine the angle Θ\Theta of the horizontal component of the plume velocity above (below) the center of the bottom (top) plate of a cylindrical Rayleigh-B\'enard cell of aspect ratio Γ≡D/L=1\Gamma \equiv D/L = 1 (DD is the diameter and L≃87L \simeq 87 mm the height) in the Rayleigh-number range 7×107≤R≤3×1097\times 10^7 \leq R \leq 3\times 10^{9} for a Prandtl number σ=6\sigma = 6. We expect that Θ\Theta gives the direction of the large-scale circulation. It oscillates time-periodically. Near the top and bottom plates Θ(t)\Theta(t) has the same frequency but is anti-correlated.Comment: 4 pages, 6 figure

    Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control

    Get PDF
    The aim of this study was to assess the diagnostic accuracy of dual-source computed tomography (DSCT) for evaluation of coronary artery disease (CAD) in a population with extensive coronary calcifications without heart rate control. Thirty patients (24 male, 6 female, mean age 63.1±11.3 years) with a high pre-test probability of CAD underwent DSCT coronary angiography and invasive coronary angiography (ICA) within 14±9 days. No beta-blockers were administered prior to the scan. Two readers independently assessed image quality of all coronary segments with a diameter ≥1.5 mm using a four-point score (1: excellent to 4: not assessable) and qualitatively assessed significant stenoses as narrowing of the luminal diameter >50%. Causes of false-positive (FP) and false-negative (FN) ratings were assigned to calcifications or motion artifacts. ICA was considered the standard of reference. Mean body mass index was 28.3±3.9 kg/m(2) (range 22.4–36.3 kg/m(2)), mean heart rate during CT was 70.3±14.2 bpm (range 47–102 bpm), and mean Agatston score was 821±904 (range 0–3,110). Image quality was diagnostic (scores 1–3) in 98.6% (414/420) of segments (mean image quality score 1.68±0.75); six segments in three patients were considered not assessable (1.4%). DSCT correctly identified 54 of 56 significant coronary stenoses. Severe calcifications accounted for false ratings in nine segments (eight FP/one FN) and motion artifacts in two segments (one FP/one FN). Overall sensitivity, specificity, positive and negative predictive value for evaluating CAD were 96.4, 97.5, 85.7, and 99.4%, respectively. First experience indicates that DSCT coronary angiography provides high diagnostic accuracy for assessment of CAD in a high pre-test probability population with extensive coronary calcifications and without heart rate control

    Human chondrocytes in tridimensional culture.

    Full text link
    peer reviewedCartilage was taken from the macroscopically normal part of human femoral heads immediately after orthopedic surgical operations for total prothesis consecutive to hip arthrosis. After clostridial collagenase digestion and repeated washings, chondrocytes (10(6) cells) were cultivated in a gyrotory shaker (100 rpm). Under these conditions, cells were kept in suspension and after 3 to 5 d formed a flaky aggregate which, on Day 10, became dense. These chondrocytes were morphologically differentiated: they had a round shape, were situated inside cavities, and were surrounded by a new matrix. Histochemical methods showed the presence of collagen and polysaccharides in cell cytoplasm and in intercellular matrix, and the immunofluorescence method using specific antisera (anticartilage proteoglycans and anti-type II collagen) showed that these two constituents were in intercellular matrix. The measurement of the amounts of proteoglycans (PG) released into culture medium and those present in chondrocyte aggregate (by a specific PG radioimmunoassay) showed a maximum production on Days 3 to 5 of culture, then the production decreased and stabilized (from Day 10 to the end of culture). The observed difference between the amounts of PG in aggregates after 20 d and those after 2 h of culture demonstrated that PG neosynthesis did occur during cultivation. This conclusion was supported by other results obtained by [14C]glucosamine incorporation in chondrocyte aggregates. Moreover, the aggregate fresh weight related to cell number (appreciated by DNA assay) increased significantly with culture duration. Three-dimensional chondrocyte culture represents an interesting model: chondrocytes were differentiated morphologically as well as biosynthetically and synthesized a new cartilage matrix

    High glycine concentration increases collagen synthesis by articular chondrocytes in vitro: acute glycine deficiency could be an important cause of osteoarthritis

    Get PDF
    Collagen synthesis is severely diminished in osteoarthritis; thus, enhancing it may help the regeneration of cartilage. This requires large amounts of glycine, proline and lysine. Previous works of our group have shown that glycine is an essential amino acid, which must be present in the diet in large amounts to satisfy the demands for collagen synthesis. Other authors have shown that proline is conditionally essential. In this work we studied the effect of these amino acids on type II collagen synthesis. Bovine articular chondrocytes were cultured under a wide range of different concentrations of glycine, proline and lysine. Chondrocytes were characterized by type II collagen immunocytochemistry of confluence monolayer cultures. Cell growth and viability were assayed by trypan blue dye exclusion method. Type II collagen was measured in the monolayer, every 48 h for 15 days by ELISA. Increase in concentrations of proline and lysine in the culture medium enhances the synthesis of type II collagen at low concentrations, but these effects decay before 1.0 mM. Increase of glycine as of 1.0 mM exceeds these effects and this increase continues more persistently by 60–75%. Since the large effects produced by proline and lysine are within the physiological range, while the effect of glycine corresponds to a much higher range, these results demonstrated a severe glycine deficiency for collagen synthesis. Thus, increasing glycine in the diet may well be a strategy for helping cartilage regeneration by enhancing collagen synthesis, which could contribute to the treatment and prevention of osteoarthriti

    Is there a gender difference in noninvasive coronary imaging? Multislice computed tomography for noninvasive detection of coronary stenoses

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Multislice computed tomography (MSCT) coronary angiography is the foremost alternative to invasive coronary angiography.</p> <p>Methods</p> <p>We sought to compare the diagnostic accuracy of MSCT in female and male patients with suspected coronary disease. Altogether 50 women and 95 men underwent MSCT with 0.5 mm detector collimation. Coronary artery stenoses of at least 50% on conventional coronary angiography were considered significant.</p> <p>Results</p> <p>The coronary vessel diameters of all four main coronary artery branches were significantly larger in men than in women. The diagnostic accuracy of MSCT in identifying patients with coronary artery disease was significantly lower for women (72%) compared with men (89%, <it>p </it>< 0.05). Also sensitivity (70% vs. 95%), positive predictive value (64% vs. 93%), and the rate of nondiagnostic examinations (14% vs. 4%, all: <it>p </it>< 0.05) were significantly worse for women. The effective radiation dose of MSCT coronary angiography was significantly higher in the examination of women (13.7 ± 1.2 mSv) than of men (11.7 ± 0.9 mSv, <it>p </it>< 0.001), mainly as a result of the fact that the radiosensitive female breast (contributing 24.5% of the dose in women) is in the x-ray path.</p> <p>Conclusion</p> <p>Noninvasive coronary angiography with MSCT might be less accurate and sensitive for women than men. Also, women are exposed to a significantly higher effective radiation dose than men.</p
    • …
    corecore