43 research outputs found

    SLAM - Based Approach to Dynamic Ship Positioning

    Full text link
    Dynamically positioned vessels, used by offshore industry, use not only satellite navigation but also different positioning systems, often referred to as reference' systems. Most of them use multiple technical devices located outside the vessel which creates some problems with their accessibility and performance. In this paper, a basic concept of reference system independent from any external device is presented, basing on hydroacoustics and Simultaneous Localization and Mapping (SLAM) method. Theoretical analysis of its operability is also performed

    A novel technique for fetal heart rate estimation from Doppler ultrasound signal

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The currently used fetal monitoring instrumentation that is based on Doppler ultrasound technique provides the fetal heart rate (FHR) signal with limited accuracy. It is particularly noticeable as significant decrease of clinically important feature - the variability of FHR signal. The aim of our work was to develop a novel efficient technique for processing of the ultrasound signal, which could estimate the cardiac cycle duration with accuracy comparable to a direct electrocardiography.</p> <p>Methods</p> <p>We have proposed a new technique which provides the true beat-to-beat values of the FHR signal through multiple measurement of a given cardiac cycle in the ultrasound signal. The method consists in three steps: the dynamic adjustment of autocorrelation window, the adaptive autocorrelation peak detection and determination of beat-to-beat intervals. The estimated fetal heart rate values and calculated indices describing variability of FHR, were compared to the reference data obtained from the direct fetal electrocardiogram, as well as to another method for FHR estimation.</p> <p>Results</p> <p>The results revealed that our method increases the accuracy in comparison to currently used fetal monitoring instrumentation, and thus enables to calculate reliable parameters describing the variability of FHR. Relating these results to the other method for FHR estimation we showed that in our approach a much lower number of measured cardiac cycles was rejected as being invalid.</p> <p>Conclusions</p> <p>The proposed method for fetal heart rate determination on a beat-to-beat basis offers a high accuracy of the heart interval measurement enabling reliable quantitative assessment of the FHR variability, at the same time reducing the number of invalid cardiac cycle measurements.</p

    Specificity of Geotechnical Measurements and Practice of Polish Offshore Operations

    Get PDF
    As offshore market in Europe grows faster and faster, new sea areas are being managed and new ideas on how to use the sea potential are being developed. In North Sea, where offshore industry conducts intensive expansion since late 1960s, numerous wind farms, oil and gas platforms and pipelines have been put into operation following extensive research, including geotechnical measurement. Recently, a great number of similar projects is under development in Baltic Sea, inter alia in Polish EEZ, natural conditions of which vary from the North Sea significantly. In this paper, those differences are described together with some solutions to problems thereby arising

    Detection of atrial fibrillation episodes in long-term heart rhythm signals using a support vector machine

    Get PDF
    Atrial fibrillation (AF) is a serious heart arrhythmia leading to a significant increase of the risk for occurrence of ischemic stroke. Clinically, the AF episode is recognized in an electrocardiogram. However, detection of asymptomatic AF, which requires a long-term monitoring, is more efficient when based on irregularity of beat-to-beat intervals estimated by the heart rate (HR) features. Automated classification of heartbeats into AF and non-AF by means of the Lagrangian Support Vector Machine has been proposed. The classifier input vector consisted of sixteen features, including four coefficients very sensitive to beat-to-beat heart changes, taken from the fetal heart rate analysis in perinatal medicine. Effectiveness of the proposed classifier has been verified on the MIT-BIH Atrial Fibrillation Database. Designing of the LSVM classifier using very large number of feature vectors requires extreme computational efforts. Therefore, an original approach has been proposed to determine a training set of the smallest possible size that still would guarantee a high quality of AF detection. It enables to obtain satisfactory results using only 1.39% of all heartbeats as the training data. Post-processing stage based on aggregation of classified heartbeats into AF episodes has been applied to provide more reliable information on patient risk. Results obtained during the testing phase showed the sensitivity of 98.94%, positive predictive value of 98.39%, and classification accuracy of 98.86%.Web of Science203art. no. 76

    IgG4-related inflammatory orbital pseudotumors : a retrospective case series

    Get PDF
    Orbital diseases may be divided into congenital defects of the orbit, infectious and inflammatory diseases, orbital tumors (including malignant and benign tumors) and injuries. Idiopathic inflammatory syndromes are often encountered within the orbit and are usually classified as orbital pseudotumors. The etiology of pseudotumors of the vision organ is unknown. Infectious agents, autoimmune disorders and improper healing are taken into consideration in the pathogenesis of this disorder. Thanks to detailed studies conducted in recent years, a new disease syndrome was identified in 2001. It is known as IgG4-related disease, and its differentiation is based on the analysis of IgG4 levels in the affected tissues. Orbital locations of the disease were first reported in Japan as late as at the end of 2009. This finding triggered the European studies on this subject. To date, no such studies have been conducted in Poland. The starting study population consisted of 167 patients with isolated infiltrative tumor diseases within the orbital region treated at the Department of Otolaryngology, Head and Neck Surgery of the Medical College Jagiellonian University in Krakow. Detailed analysis and diagnostic screening for IgG4-related disease was performed in a total of 17 patients diagnosed with orbital pseudotumor

    Fetal electrocardiograms, direct and abdominal with reference heartbeat annotations

    Get PDF
    Monitoring fetal heart rate (FHR) variability plays a fundamental role in fetal state assessment. Reliable FHR signal can be obtained from an invasive direct fetal electrocardiogram (FECG), but this is limited to labour. Alternative abdominal (indirect) FECG signals can be recorded during pregnancy and labour. Quality, however, is much lower and the maternal heart and uterine contractions provide sources of interference. Here, we present ten twenty-minute pregnancy signals and 12 five-minute labour signals. Abdominal FECG and reference direct FECG were recorded simultaneously during labour. Reference pregnancy signal data came from an automated detector and were corrected by clinical experts. The resulting dataset exhibits a large variety of interferences and clinically significant FHR patterns. We thus provide the scientific community with access to bioelectrical fetal heart activity signals that may enable the development of new methods for FECG signals analysis, and may ultimately advance the use and accuracy of abdominal electrocardiography methods.Web of Science71art. no. 20

    ТЕЛЕСНЫЕ НАКАЗАНИЯ

    Get PDF
    Great expectations are connected with application of indirect fetal electrocardiography (FECG), especially for home telemonitoring of pregnancy. Evaluation of fetal heart rate (FHR) variability, when determined from FECG, uses the same criteria as for FHR signal acquired classically—through ultrasound Doppler method (US). Therefore, the equivalence of those two methods has to be confirmed, both in terms of recognizing classical FHR patterns: baseline, accelerations/decelerations (A/D), long-term variability (LTV), as well as evaluating the FHR variability with beat-to-beat accuracy—short-term variability (STV). The research material consisted of recordings collected from 60 patients in physiological and complicated pregnancy. The FHR signals of at least 30 min duration were acquired dually, using two systems for fetal and maternal monitoring, based on US and FECG methods. Recordings were retrospectively divided into normal (41) and abnormal (19) fetal outcome. The complex process of data synchronization and validation was performed. Obtained low level of the signal loss (4.5% for US and 1.8% for FECG method) enabled to perform both direct comparison of FHR signals, as well as indirect one—by using clinically relevant parameters. Direct comparison showed that there is no measurement bias between the acquisition methods, whereas the mean absolute difference, important for both visual and computer-aided signal analysis, was equal to 1.2 bpm. Such low differences do not affect the visual assessment of the FHR signal. However, in the indirect comparison the inconsistencies of several percent were noted. This mainly affects the acceleration (7.8%) and particularly deceleration (54%) patterns. In the signals acquired using the electrocardiography the obtained STV and LTV indices have shown significant overestimation by 10 and 50% respectively. It also turned out, that ability of clinical parameters to distinguish between normal and abnormal groups do not depend on the acquisition method. The obtained results prove that the abdominal FECG, considered as an alternative to the ultrasound approach, does not change the interpretation of the FHR signal, which was confirmed during both visual assessment and automated analysis

    Insights from the STICH trial: Change in left ventricular size after coronary artery bypass grafting with and without surgical ventricular reconstruction

    Get PDF
    ObjectiveThe present analysis of the Surgical Treatment for Ischemic Heart Failure randomized trial data examined the left ventricular volumes at baseline and 4 months after surgery to determine whether any magnitude of postoperative reduction in end-systolic volume affected survival after coronary artery bypass grafting alone compared with bypass grafting plus surgical ventricular reconstruction.MethodsOf the 1000 patients randomized, 555 underwent an operation and had a paired imaging assessment with the same modality at baseline and 4 months postoperatively. Of the remaining 455 patients, 424 either died before the 4-month study or did not have paired imaging tests and were excluded, and 21 were not considered because they had died before surgery or did not receive surgery.ResultsSurgical ventricular reconstruction resulted in improved survival compared with coronary artery bypass grafting alone when the postoperative end-systolic volume index was 70 mL/m2 or less. However, the opposite was true for patients achieving a postoperative volume index greater than 70 mL/m2. A reduction in the end-systolic volume index of 30% or more compared with baseline was an infrequent event in both treatment groups and did not produce a statistically significant survival benefit with ventricular reconstruction.ConclusionsIn patients undergoing coronary artery bypass grafting plus surgical ventricular reconstruction, a survival benefit was realized compared with bypass alone, with the achievement of a postoperative end-systolic volume index of 70 mL/m2 or less. Extensive ventricular remodeling at baseline might limit the ability of ventricular reconstruction to achieve a sufficient reduction in volume and clinical benefit
    corecore