6 research outputs found

    Sensitive Determination of Cd in Small-Volume Samples by Miniaturized Liquid Drop Anode Atmospheric Pressure Glow Discharge Optical Emission Spectrometry

    No full text
    A novel liquid drop anode (LDA) direct current atmospheric pressure glow discharge (dc-APGD) system was applied for direct determination of Cd in liquid microsamples (50 μL) by optical emission spectrometry (OES). The microdischarge was generated in open-to-air atmosphere between a solid pin type tungsten cathode and a liquid drop placed on a graphite disk anode. The arrangement of the graphite disk placed on a PTFE chip platform as well as the solid pin type cathode was simple and robust. The limit of detection (LOD) of Cd for the developed LDA-APGD-OES method was 0.20–0.40 μg L<sup>–1</sup>, while precision (as the relative standard deviation for the repeated measurements) was within 2–5%. By using the liquid drop of 50 μL, the linearity range of 1–1000 μg L<sup>–1</sup> was achieved. The effect of addition of the low-molecular weight (LMW) organic compounds, easily ionized elements (EIEs), i.e., Ca, K, Mg, and Na, as well as the foreign ions (Al, Cu, Fe, Mn, Zn) to the solution on the <i>in situ</i> atomization and excitation processes occurred during operation of the LDA-APGD system, and the response of Cd was studied. Validation of the proposed method was demonstrated by analysis of <i>Lobster hepatopancreas</i> (TORT-2), pig kidney (ERM-BB186), and groundwater (ERM-CA615) certified reference materials (CRMs) and recoveries of Cd from water samples spiked with 25 μg L<sup>–1</sup> of Cd. Very good agreement between the found and certified values of Cd in the CRMs (the recoveries were within the range of 96.3–99.6%) indicated trueness of the method and its reliability for determination of traces of Cd. In the case of the spiked water samples, the recoveries obtained were in the range from 95.2 to 99.5%

    Surface recombination and space-charge-limited photocurrent-voltage (PC-V) measurements in (Cd,Mn)Te samples. Kinetics of photocurrent (PC)

    Full text link
    Photocurrent-voltage characteristic (PC-V) is a method of determining the critical parameter in X-ray and gamma-ray detector plates, i.e., the carrier mobility - lifetime product, mt. We show on the (Cd,Mn)Te samples that the measurement results depend strongly on the surface treatment and the charge space distribution. The PC-V characteristics obtained for hv > Eg and hv ~ Eg indicated that etching with 20% HCl caused an appearance of a significant concentration of very shallow surface traps at the (Cd,Mn)Te sample surface. These traps seriously changed the measurements of PC-V characteristics and PC kinetics. We also noticed a small contribution of holes to photoconductivity in the PC kinetics. The PC-V characteristics measurements for hv > Eg may test the detector plate surface quality.Comment: 16 pages, 13 figure

    The cosmic ray detector for the NICA collider

    No full text
    Multi-Purpose Detector (MPD) is a main part of a new Ion Collider fAcility (NICA) located in Dubna, Russia. To increase MPD functionality, it was proposed to add an additional muon trigger system for off-beam calibration of the MPD sub-detectors and for rejection of cosmic ray background during experiments. The system could also be very useful for astrophysical observations of cosmic showers initiated by high energy primary particles. This article describes the main goals of MCORD detector and the early stage of MCORD design, based on plastic scintillators with silicon photomultiplier photodetectors (SiPM) for scintillation readout and electronic system based on MicroTCA standard

    The cosmic ray detector for the NICA collider

    Get PDF
    Multi-Purpose Detector (MPD) is a main part of a new Ion Collider fAcility (NICA) located in Dubna, Russia. To increase MPD functionality, it was proposed to add an additional muon trigger system for off-beam calibration of the MPD sub-detectors and for rejection of cosmic ray background during experiments. The system could also be very useful for astrophysical observations of cosmic showers initiated by high energy primary particles. This article describes the main goals of MCORD detector and the early stage of MCORD design, based on plastic scintillators with silicon photomultiplier photodetectors (SiPM) for scintillation readout and electronic system based on MicroTCA standard
    corecore