43 research outputs found

    Li-ion Batery Management System

    Get PDF
    Tato práce se zabývá akumulátory, problematikou jejich parametrů a nabíjení. Zaměřuje se na akumulátory, založené na Lithium. Dále se zabývá systémem, který měří a umožňuje dobíjet Li-iontové akumulátory. Zvláště řídícím obvodem BQ76920, umožňujícím správu až 5 dobíjecích článků. Tento systém byl otestován, změřen a vyhodnocen na DPS.This thesis is about systems for Li-ion batteries. The system consists of measuring and charging. The main part of system is 3 to 5-Series Cell Li-Ion and Li-Phosphate Battery Monitor chip BQ76920. The result of this thesis is printed circuit board (PCB) with BQ76920 and a box contain PCB and battery pack. The system has been tested and measured and evaluated in this thesis.

    Visual Object Tracking in Realtime

    Get PDF
    Sledování obecného objektu na zařízení s omezenými prostředky v reálném čase je obtížné. Mnoho algoritmů věnujících se této problematice již existuje. V této práci se s nimi seznámíme. Různé přístupy k této problematice jsou diskutovány včetně hlubokého učení. Představeny jsou reprezentace objektu, datasety i metriky pro vyhodnocování. Mnoho sledovacích algorimů je představeno, osm z nich je implementováno a vyhodnoceno na VOT datasetu.Tracking a general object in real time on an embedded device is a challenge. Many algorithms for tracking objects have been developed. This thesis introduces some of these algorithms. Different approaches are discussed, including deep learning. Object representations, evaluations datasets and metrics are shown. Many tracking algorithms are presented, eight of them are implemented and evaluated on the VOT dataset.

    Measurement of cardiovascular parameters

    Get PDF
    Cílem bakalářské práce je seznámení se s problematikou měření parametrů kardiovaskulárního systému, realizace měření těchto parametrů, následná analýza, ukázat statistický postup ověřování hypotéz v této oblasti a konečně prezentace naměřených průběhů včetně automatické detekce tepové frekvence z EKG signálu ve vytvořeném programu v prostředí Guide systému Matlab. Na základě teoretických poznatků bylo dle vlastního návrhu provedeno měření systémem Biopac a rtuťovým tonometrem. Parametry, jež byly měřeny na skupině pěti lidí: EKG, krevní tlak a tepová frekvence před a po zátěži. Po zpracování dat byla provedena statistická analýza, jejímž cílem bylo ukázat postup ověření hypotézy, zda a jak se mění měřené parametry kardiovaskulárního systému po zátěži. Následně byla naměřená data přenesena do prostředí Matlab. Prezentace průběhů (vytvořený program) zahrnuje časové a spektrální analýzy (užití Fourierovy transformace) signálů EKG, automatickou detekci tepové frekvence z EKG signálu, analýzu proměnlivosti tepové frekvence (HRV) – tachogram spolu s detailní analýzou HRV spekter (spekter proměnlivosti tepové frekvence – souvisí s aktivitou sympatiku a parasympatiku), které se rovněž užívají v klinické praxi stejně jako ostatní měřené parametry kardiovaskulárního systému.The aim of the bachelor’s thesis is to get acquainted with the measurement of cardiovascular parameters, to realize the measurment of these parameters, to analyze them, show the statistic procedure of verifying hypotheses in this spere and finally the presentation of measured data including automatical detection of the heart rate from ECG signal in created program in Guide of Matlab system. On the basis of the theory was done the measurment on own suggestion with the Biopac system and with the quicksilver tonomether. The parameters, that were measured on the group of five people: ECG, blood pressure and the pulse frequency before and after the load. After the data processing was done the statistic analysis, the aim of this analysis was to show the procedure of verifying hypothesis, if and how are these measured parameters of cardiovascular system changing. After that the measured data were transported into Matlab system. The presentation of measured data (created program) contains the time domain and spectral analyses (using Fourier transform) of ECG signal, automatical detection of the heart rate from ECG signal, analysis of the heart rate variability (HRV) – tachogram together with detailed analysis of HRV spectra (spectra of heart rate variability – relating with parasympathetic and sympathetic activity), that are using in clinical practice too, just as the other measured parametres of the cardiovascular system.

    Color Correction for 3D scanner and 3D printer

    Get PDF
    Tato práce se zabývá barevnou korekcí řetězce, který začíná u 3D skeneru Artec MHT, a končí u 3D tiskárny (CJP technologie) 3D systems Zprinter 650. Cílem je řízení barevné interpretace celého řetězce od skenování povrchu reálných těles a jejich zobrazení až po výtisk jejich 3D modelu, včetně barevných textur. Princip snímání povrchu modelu pomocí 3D skeneru je podobný jako u fotoaparátu, který snímá obraz za pomocí běžného CMOS čipu. Z tohoto důvodu byly pro správnou funkci barevné korekce nalezeny metody, které upravují barvy blíže k reálným snímaným barvám. Při naplňování cílů práce, byly snímány palety barev fotoaparátem a následně takto pořízená digitální data byla analyzována programem Darktable. Analýza spočívala v porovnávání nasnímaných barevných dat s daty pořízenými spektrofotometrem a vytváření ICC profilů pro zajištění barvové přesnosti v digitálních datech při jejich pořízení, přípravě a interpretaci. Cílem bylo zajištění barvové přesnosti v digitálních datech. Poté byl stejný princip aplikován na data pořízená 3D skenerem s cílem vytvoření ICC profilu 3D skeneru. Jako výchozí bod byly studovány a uplatněny principy ve 2D fotografování a 2D tisku, to bylo možné díky tomu, že princip je u těchto zařízeních principiálně podobný jako 3D zařízení. Stejně jako u 3D skeneru i 3D tiskárna je v principu CJP (Color Jet Printing) stejná s 2D tiskárnou, a proto byl znovu pro její kalibraci využit princip kalibrace na 2D tiskových zařízeních. Byly definovány postupy, které upravují odstín barvy ke spektrofotometricky správným odstínům barev výsledného tisku na 3D tiskárně. Byly také vytištěny barvové vzorníky, u kterých bylo provedeno ověření kvality tisku. Bylo zjištěno, že s fotoaparátem, který byl použit pro objektivní měření v L*a*b* souřadnicích nezávislého prostoru, je jakékoliv nastavení barev a jejich úprava velmi citlivá na byť jen malé nepřesnosti. Bylo zjištěno, že není snadné získat přesné fotografie s~přesnými barvami do odchylky Delta EThis thesis deals with color correction of a chain that starts with the 3D Artec MHT scanner, and ends with the 3D printers (CJP – Color Jet Printing technology). In principle, it is necessary to control the color interpretation of the entire chain from the scanning of real models to the 3D print model. With color properties and their color shade, including color textures. The principle of model surface scanning using a 3D scanner is in the same principle as photo camera which scans using a conventional CMOS chip. For this reason, color palettes were scanned using the photo camera and the resulting digital data were analyzed by the Darktable software. This analysis consisted of comparing the scanned color shades of the surface with the spectrofotometer measured data. The main goal of this method was to achieve color precision in the digital data during their acquirement, adjustment and interpretation. Then the same principle was applied to the data acquired by the 3D scanner to create an ICC profile of the 3D scanner. Because the 3D printer (CJP – Color Jet Printing) uses the same principle as the 2D printer, the 2D printing device calibration principle was used again to calibrate it. There have been defined procedures that adjust the color shade to the spectrophotometrically correct shades of the resulting print on a 3D printer. Color swatches were also printed for print quality verification. It has been found that with photo camera, which was used for objective measurement in the L*a*b* coordinates of independent space, any color setting and their adjustment is very sensitive to even small imprecisions. It has been found that it is not easy to obtain accurate colors within the Detla E

    Localization of wireless devices by means of electromagnetics and ultrasound signals

    Get PDF
    Práce se věnuje přiblížení práce se zařízeními, které pracují s ultrazvukovým a rádiovým signálem. Pomocí tohoto signálu, vypočítávají vzdálenost. A následně vyhodnocují lokaci. Byla vytvořena java aplikace, která komunikuje přes TCP port, separuje data z typu String do typu Integer. A následně zpracovává Integer.Work is devoted to review handle with beacon, which work with ultrasound and radiowaves signal. This signal via calculate distance. And then calculate lacation. Was created java application,that communicates via TCP port, separates data that are type String to type Integer. And then works with integer.

    Customer Satisfaction

    Get PDF
    Bakalarska prace se zameruje na problematiku v oblasti spokojenosti zakazniku maloobchodniho sportovniho retezce prodejen Decathlon, a to konkretne na pobocce v Brne Ivanovicich. V teoreticke cast popisuje pojmy jako marketingovy vyzkum, zakaznik a jeho spokojenost nebo marketing samotny. Nasleduje analyza soucasneho prostredi a sestaveni dotaznikoveho setreni. Na zaklade analyticke casti prace obsahuje vlastni navrhy na zvyseni spokojenosti zakazniku na dane prodejne.This Bachalor thesis is focused on problematics in area of customer satisfaction in retail sport chain Decathlon, specifically in store in Brno Ivanovice. Theoretical part describes what is marketing research, customer, his satisfaction and marketing itself. Following by an analysis of the current environment and compiling a questionnaire survey based on analytical part. Thesis contains own suggestion for the increase of customer satisfaction in the store.

    Dynamic Focusing in Ultrasound Tomography

    Get PDF
    Cílem diplomové práce je seznámení se s problematikou dynamické fokusace v konvenčních ultrazvukových zobrazovacích systémech, modifikace metody pro průzvučnou ultrazvukovou tomografii a realizace a vyhodnocení této modifikace na simulovaných a reálných datech v přehledném grafickém rozhraní. Byla provedena modifikace dynamické fokusace pro 3D průzvučný ultrazvukový tomograf vyvinutý v Karslruhe. Potřebná simulovaná data pro fokusaci byla generována upraveným, již existujícím programem. Na těchto datech a na reálných datech byl odzkoušen a vyhodnocen vytvořený program dynamické fokusace.The aim of the master’s thesis, is to get acquainted with the dynamic focusing in conventional ultrasound systems, to modify this method for ultrasound computer tomography and to realize and interpret this modification on simulated and real data in a transparent graphic interface. The modification of the dynamic focusing was executed for the 3D ultrasound computer tomograph developed in Karlsruhe. Simulated data, that are necessary for focusing, were generated by existing program, which was adjusted. The new created program of the dynamic focusing was tested and evaluated with those simulated and real data.

    Assessment of the degree of adherence of medical laboratories to KDIGO 2012 guideline for evaluation and management of CKD in Czechia and Slovakia

    Get PDF
    Introduction: The aim of the study is to assess the degree of adherence of medical laboratories to Kidney Disease Improving Global Outcomes (KDIGO) 2012 Clinical Practice Guideline for the Evaluation and Management of Chronic Kidney Disease (CKD) in laboratory practice in Czechia and Slovakia. Materials and methods: An electronic questionnaire on adherence to KDIGO 2012 guideline was designed by an external quality assessment (EQA) provider SEKK spol. s.r.o. The questionnaire was placed and distributed through website to all medical biochemistry laboratories in Czechia and Slovakia (N = 396). Results: A total of 212 out of 396 laboratories responded to the questions, though some laboratories only answered some questions, those applicable to their practice. A total of 48 out of 212 laboratories adopted the KDIGO 2012 guideline in full extent. The metrological traceability of creatinine measurement to standard reference material of SRM 967 was declared by 180 out of 210 laboratories (two of the responding laboratories did not measure creatinine). Thirty laboratories are not well educated on traceability of creatinine measurement and seven laboratories do not calculate estimated glomerular filtration rate (eGFR). Both urinary albumin concentration and albumin to creatinine ratio are reported by 144 out of 175 laboratories (37 of the responding laboratories did not measure urinary albumin). Conclusion: Majority of laboratories in Czechia and Slovakia adopted some parts of the KDIGO 2012 guideline in their practice, but only 23% of the laboratories apply them completely. Thus, further education and action should be conducted to improve its implementation
    corecore