42 research outputs found

    A touching movement : force control turns machining robots into universal tools

    Full text link
    ABB has written a new chapter in the book of robot applications. While in the past it had been a tedious and time-consuming effort to program a robot for delicate fine-tuning operations, robots can now learn how to best manage such tasks themselves. This innovative approach can reduce overall programming times by up to 80 percent for robots used to grind castings, vastly improving productivity levels. With ABB’s new Flex Finishing system featuring RobotWare Machining FC (force control), one of the last real barriers to productivity improvement in this sector has been lifted

    A new nail with a locking blade for complex proximal humeral fractures

    Get PDF
    INTRODUCTION: The objective of this study was to assess the clinical outcome of displaced proximal humerus fracture treated with a new locking blade nail. MATERIALS AND METHODS: This prospective study included a series of 92 patients with acute fracture of the proximal humerus treated in one hospital level I trauma centre with locking blade nail between December 2010 and December 2013. According to the Neer classification, all fractures were two- to four-part fractures. Age adopted Constant score, DASH and visual analogue scores were used as outcome measures. RESULTS: A total of 92 patients were enrolled in the study. However, 29 patients were excluded due to loss to follow-up and death. Ultimately, 63 patients were available for final follow-up and data analysis. The mean duration of follow-up was 22 months (range 16–48 months). On average at 1 year, all fractures had united. The mean weighted Constant score was 84.2 % and the median disabilities of the arm, shoulder and hand (DASH) score was 26, the range of elevation was 115 and range of abduction was 97. The head shaft angle was 130, and pain visual analogue was 1.6. We found that 5 of the 63 patients (8 %) demonstrated complications. Two patients (3 %) displayed secondary displacement and require device removal. Two patients (3 %) had impingement due to prominent metal work, and one patient had a superficial wound infection which was treated with a course of antibiotics. CONCLUSION: Our study shows excellent results with new locking blade nail for displaced proximal humerus fractures. We think the locking blade nail offers stiff triangular fixation of the head fragment and support of the medial calcar region to prevent secondary varus collapse. LEVEL OF EVIDENCE: III
    corecore