16 research outputs found

    Funkcja endoprotezy onkologicznej w nawrotowym mi臋saku kostno pochodnym dalszego ko艅ca ko艣ci udowej .

    Get PDF
    Endoprothesis is the commonly used method of segmental reconstruction after bone tumor resection around knee. To achieve stability after extensive removal of knee structures, hinged endoprostheses are usually being preferred as a limb salvage procedure. Despite advances in diagnostics and preoperative tumor chemotherapy and radiotherapy, as well as meticulous intraoperative preparation, local tumor recurrence is still possible. We analyzed 22 patients with osteosarcoma in distal femur who underwent the knee arthroplasty with modular replacement system between 2002 and 2007. Three of them (two females aged 33 and 44 and one male aged 29) developed local recurrence 7, 9 and 12 months after operation. All of them were offered the amputation or metastatectomy, as well as further chemotherapy, and all refused. Reasons for refusal included disseminated disease, uncertain prognosis of amputation treatment and still good functional outcome despite existing tumor around the prosthesis. Two of the above mentioned patients deceased from disseminated disease 7 and 11 months later, one patient is still being followed 10 months long. Clinical examinations have shown the effective and satisfactory prosthesis functions in reported patients during the whole observation period. We have concluded that limb salvage surgery with implantation of hinged knee endoprosthesis in tumors in distal femur provide satisfactory functional outcome even when local tumor recurrence is found.Endoproteza jest powszechnie u偶ywan膮 metod膮 segmentalnej rekonstrukcji po resekcji guz贸w ko艣ci w okolicy stawu kolanowego. Dla uzyskania stabilno艣ci po rozleg艂ym usuni臋ciu struktur stawu kolanowego, protezy zawiasowe s膮 zazwyczaj preferowane jako procedury oszcz臋dzaj膮ce ko艅czyn臋. Pomimo zaawansowanej diagnostyki i przedoperacyjnej chemioterapii i radioterapii guza, jak r贸wnie偶 drobiazgowego 艣r贸doperacyjnego preparowania, miejscowa wznowa guza nadal jest mo偶liwa. Przeanalizowali艣my 22 pacjent贸w z mi臋sakiem kostnopochodnym dalszego ko艅ca ko艣ci udowej, kt贸rzy zostali poddani endoprotezoplastyce poresekcyjnej stawu kolanowego z u偶yciem modularnego systemu pomi臋dzy 2002r. a 2007r. U trzech z nich (dwie kobiety w wieku 33 i 44 lata i jeden m臋偶czyzna w wieku 29 lat) rozwin臋艂a si臋 miejscowa wznowa 7, 9 i 12 miesi臋cy po operacji. Zaproponowano im amputacj臋 lub resekcj臋 wznowy, jak r贸wnie偶 dalsz膮 chemioterapi臋. Wszyscy odm贸wili. Przyczynami odmowy by艂y: rozsiana choroba nowotworowa, niepewne rokowanie po amputacji i wci膮偶 dobry czynno艣ciowy wynik pomimo istniej膮cego guza wok贸艂 endoprotezy. Dw贸ch z tych pacjent贸w zmar艂o z powodu rozsianego procesu nowotworowego 7 i 11 miesi臋cy p贸藕niej, a trzeci chory by艂 jeszcze obserwowany przez kolejnych 10 miesi臋cy. Kliniczna ocena pokaza艂a wydoln膮 i zadawalaj膮c膮 funkcj臋 endoprotezy u opisywanych chorych podczas ca艂ego okresu obserwacji. Stwierdzili艣my, 偶e operacje oszcz臋dzaj膮ce ko艅czyn臋 z wszczepieniem endoprotezy poresekcyjnej, zawiasowej stawu kolanowego w guzach dalszego ko艅ca ko艣ci udowej przynosi zadawalaj膮cy wynik czynno艣ciowy nawet kiedy wyst臋puje miejscowa wznowa guza

    LUMiC(A (R)) Endoprosthetic Reconstruction After Periacetabular Tumor Resection:Short-term Results

    Get PDF
    Reconstruction of periacetabular defects after pelvic tumor resection ranks among the most challenging procedures in orthopaedic oncology, and reconstructive techniques are generally associated with dissatisfying mechanical and nonmechanical complication rates. In an attempt to reduce the risk of dislocation, aseptic loosening, and infection, we introduced the LUMiC(A (R)) prosthesis (implantcast, Buxtehude, Germany) in 2008. The LUMiC(A (R)) prosthesis is a modular device, built of a separate stem (hydroxyapatite-coated uncemented or cemented) and acetabular cup. The stem and cup are available in different sizes (the latter of which is also available with silver coating for infection prevention) and are equipped with sawteeth at the junction to allow for rotational adjustment of cup position after implantation of the stem. Whether this implant indeed is durable at short-term followup has not been evaluated. (1) What proportion of patients experience mechanical complications and what are the associated risk factors of periacetabular reconstruction with the LUMiC(A (R)) after pelvic tumor resection? (2) What proportion of patients experience nonmechanical complications and what are the associated risk factors of periacetabular reconstruction with the LUMiC(A (R)) after pelvic tumor resection? (3) What is the cumulative incidence of implant failure at 2 and 5 years and what are the mechanisms of reconstruction failure? (4) What is the functional outcome as assessed by Musculoskeletal Tumor Society (MSTS) score at final followup? We performed a retrospective chart review of every patient in whom a LUMiC(A (R)) prosthesis was used to reconstruct a periacetabular defect after internal hemipelvectomy for a pelvic tumor from July 2008 to June 2014 in eight centers of orthopaedic oncology with a minimum followup of 24 months. Forty-seven patients (26 men [55%]) with a mean age of 50 years (range, 12-78 years) were included. At review, 32 patients (68%) were alive. The reverse Kaplan-Meier method was used to calculate median followup, which was equal to 3.9 years (95% confidence interval [CI], 3.4-4.3). During the period under study, our general indications for using this implant were reconstruction of periacetabular defects after pelvic tumor resections in which the medial ilium adjacent to the sacroiliac joint was preserved; alternative treatments included hip transposition and saddle or custom-made prostheses in some of the contributing centers; these were generally used when the medial ilium was involved in the tumorous process or if the LUMiC(A (R)) was not yet available in the specific country at that time. Conventional chondrosarcoma was the predominant diagnosis (n = 22 [47%]); five patients (11%) had osseous metastases of a distant carcinoma and three (6%) had multiple myeloma. Uncemented fixation (n = 43 [91%]) was preferred. Dual-mobility cups (n = 24 [51%]) were mainly used in case of a higher presumed risk of dislocation in the early period of our study; later, dual-mobility cups became the standard for the majority of the reconstructions. Silver-coated acetabular cups were used in 29 reconstructions (62%); because only the largest cup size was available with silver coating, its use depended on the cup size that was chosen. We used a competing risk model to estimate the cumulative incidence of implant failure. Six patients (13%) had a single dislocation; four (9%) had recurrent dislocations. The risk of dislocation was lower in reconstructions with a dual-mobility cup (one of 24 [4%]) than in those without (nine of 23 [39%]) (hazard ratio, 0.11; 95% CI, 0.01-0.89; p = 0.038). Three patients (6%; one with a preceding structural allograft reconstruction, one with poor initial fixation as a result of an intraoperative fracture, and one with a cemented stem) had loosening and underwent revision. Infections occurred in 13 reconstructions (28%). Median duration of surgery was 6.5 hours (range, 4.0-13.6 hours) for patients with an infection and 5.3 hours (range, 2.8-9.9 hours) for those without (p = 0.060); blood loss was 2.3 L (range, 0.8-8.2 L) for patients with an infection and 1.5 L (range, 0.4-3.8 L) for those without (p = 0.039). The cumulative incidences of implant failure at 2 and 5 years were 2.1% (95% CI, 0-6.3) and 17.3% (95% CI, 0.7-33.9) for mechanical reasons and 6.4% (95% CI, 0-13.4) and 9.2% (95% CI, 0.5-17.9) for infection, respectively. Reasons for reconstruction failure were instability (n = 1 [2%]), loosening (n = 3 [6%]), and infection (n = 4 [9%]). Mean MSTS functional outcome score at followup was 70% (range, 33%-93%). At short-term followup, the LUMiC(A (R)) prosthesis demonstrated a low frequency of mechanical complications and failure when used to reconstruct the acetabulum in patients who underwent major pelvic tumor resections, and we believe this is a useful reconstruction for periacetabular resections for tumor or failed prior reconstructions. Still, infection and dislocation are relatively common after these complex reconstructions. Dual-mobility articulation in our experience is associated with a lower risk of dislocation. Future, larger studies will need to further control for factors such as dual-mobility articulation and silver coating. We will continue to follow our patients over the longer term to ascertain the role of this implant in this setting. Level IV, therapeutic study
    corecore