100 research outputs found

    Associations Between Radiation Oncologist Demographic Factors and Segmentation Similarity Benchmarks: Insights From a Crowd-Sourced Challenge Using Bayesian Estimation

    Get PDF
    PURPOSE: The quality of radiotherapy auto-segmentation training data, primarily derived from clinician observers, is of utmost importance. However, the factors influencing the quality of clinician-derived segmentations are poorly understood; our study aims to quantify these factors. METHODS: Organ at risk (OAR) and tumor-related segmentations provided by radiation oncologists from the Contouring Collaborative for Consensus in Radiation Oncology data set were used. Segmentations were derived from five disease sites: breast, sarcoma, head and neck (H&N), gynecologic (GYN), and GI. Segmentation quality was determined on a structure-by-structure basis by comparing the observer segmentations with an expert-derived consensus, which served as a reference standard benchmark. The Dice similarity coefficient (DSC) was primarily used as a metric for the comparisons. DSC was stratified into binary groups on the basis of structure-specific expert-derived interobserver variability (IOV) cutoffs. Generalized linear mixed-effects models using Bayesian estimation were used to investigate the association between demographic variables and the binarized DSC for each disease site. Variables with a highest density interval excluding zero were considered to substantially affect the outcome measure. RESULTS: Five hundred seventy-four, 110, 452, 112, and 48 segmentations were used for the breast, sarcoma, H&N, GYN, and GI cases, respectively. The median percentage of segmentations that crossed the expert DSC IOV cutoff when stratified by structure type was 55% and 31% for OARs and tumors, respectively. Regression analysis revealed that the structure being tumor-related had a substantial negative impact on binarized DSC for the breast, sarcoma, H&N, and GI cases. There were no recurring relationships between segmentation quality and demographic variables across the cases, with most variables demonstrating large standard deviations. CONCLUSION: Our study highlights substantial uncertainty surrounding conventionally presumed factors influencing segmentation quality relative to benchmarks

    Application of volumetric modulated arc therapy (VMAT) in a dual-vendor environment

    Get PDF
    Background and Purpose The purpose of this study was to assess plan quality and treatment time achievable with the new VMAT optimization tool implemented in the treatment planning system Oncentra MasterPlan® as compared to IMRT for Elekta SynergyS® linear accelerators. Materials and methods VMAT was implemented on a SynergyS® linear accelerator (Elekta Ltd., Crawley, UK) with Mosaiq® record and verify system (IMPAC Medical Systems, Sunnyvale, CA) and the treatment planning system Oncentra MasterPlan® (Nucletron BV, Veenendaal, the Netherlands). VMAT planning was conducted for three typical target types of prostate cancer, hypopharynx/larynx cancer and vertebral metastases, and compared to standard IMRT with respect to plan quality, number of monitor units (MU), and treatment time. Results For prostate cancer and vertebral metastases single arc VMAT led to similar plan quality as compared to IMRT. For treatment of the hypopharynx/larynx cancer, a second arc was necessary to achieve sufficient plan quality. Treatment time was reduced in all cases to 35% to 43% as compared to IMRT. Times required for optimization and dose calculation, however, increased by a factor of 5.0 to 6.8. Conclusion Similar or improved plan quality can be achieved with VMAT as compared to IMRT at reduced treatment times but increased calculation times

    Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A phase III multi-centre randomised trial (ROSEL) has been initiated to establish the role of stereotactic radiotherapy in patients with operable stage IA lung cancer. Due to rapid changes in radiotherapy technology and evolving techniques for image-guided delivery, guidelines had to be developed in order to ensure uniformity in implementation of stereotactic radiotherapy in this multi-centre study.</p> <p>Methods/Design</p> <p>A Quality Assurance Working Party was formed by radiation oncologists and clinical physicists from both academic as well as non-academic hospitals that had already implemented stereotactic radiotherapy for lung cancer. A literature survey was conducted and consensus meetings were held in which both the knowledge from the literature and clinical experience were pooled. In addition, a planning study was performed in 26 stage I patients, of which 22 were stage 1A, in order to develop and evaluate the planning guidelines. Plans were optimised according to parameters adopted from RTOG trials using both an algorithm with a simple homogeneity correction (Type A) and a more advanced algorithm (Type B). Dose conformity requirements were then formulated based on these results.</p> <p>Conclusion</p> <p>Based on current literature and expert experience, guidelines were formulated for this phase III study of stereotactic radiotherapy versus surgery. These guidelines can serve to facilitate the design of future multi-centre clinical trials of stereotactic radiotherapy in other patient groups and aid a more uniform implementation of this technique outside clinical trials.</p

    Determination of the optimal matching position for setup images and minimal setup margins in adjuvant radiotherapy of breast and lymph nodes treated in voluntary deep inhalation breath-hold

    Get PDF
    Background Adjuvant radiotherapy (RT) of left-sided breast cancer is increasingly performed in voluntary deep inspiration breath-hold (vDIBH). The aim of this study was to estimate the reproducibility of breath-hold level (BHL) and to find optimal bony landmarks for matching of orthogonal setup images to minimise setup margins. Methods 1067 sets of images with an orthogonal setup and tangential field from 67 patients were retrospectively analysed. Residual position errors were determined in the tangential treatment field images for different matches of the setup images. Variation of patient posture and BHL were analysed for position errors of the vertebrae, clavicula, ribs and sternum in the setup and tangential field images. The BHL was controlled with a Varian RPM® system. Setup margins were calculated using the van Herk’s formula. Patients who underwent lymph node irradiation were also investigated. Results For the breast alone, the midway compromise of the ribs and sternum was the best general choice for matching of the setup images. The required margins were 6.5 mm and 5.3 mm in superior-inferior (SI) and lateral/anterior-posterior (LAT/AP) directions, respectively. With the individually optimised image matching position also including the vertebrae, slightly smaller margins of 6.0 mm and 4.8 mm were achieved, respectively. With the individually optimised match, margins of 7.5 mm and 10.8 mm should be used in LAT and SI directions, respectively, for the lymph node regions. These margins were considered too large. The reproducibility of the BHL was within 5 mm in the AP direction for 75% of patients. Conclusions The smallest setup margins were obtained when the matching position of the setup images was individually optimised for each patient. Optimal match for the breast alone is not optimal for the lymph node region, and, therefore, a threshold of 5 mm was introduced for residual position errors of the sternum, upper vertebrae, clavicula and chest wall to retain minimal setup margins of 5 mm. Because random interfraction variation in patient posture was large, we recommend daily online image guidance. The BHL should be verified with image guidance.BioMed Central open acces
    corecore