120 research outputs found

    Clinical trial of FK 506 immunosuppression in adult cardiac transplantation

    Get PDF
    The new immunosuppressive agent FK 506 was used as primary immunotherapy in conjunction with low-dose steroids and azathioprine in 72 patients subsequent to orthotopic cardiac transplantation. Overall patient survival at a mean follow-up of 360 days was 92%. The number of episodes of cardiac rejection (grade 3A or greater) within 90 days of transplantation was 0.95 per patient. The actuarial freedom from rejection at 90 days was 41%. Achievement of this level of immunosuppression is comparable with that of cyclosporine-based triple-drug therapy with OKT3 immunoprophylaxis. Thirty percent of patients were tapered off all steroids, and the average steroid dose in the group who received steroids was 8.6 mg of prednisone per day. The incidence of infection reflected the diminished necessity for steroids: seven major infections (10%) and 11 minor infections (16%). Renal dysfunction occurred during the perioperative period in most patients in this trial. However, the incidence of hypertension was 54% compared with 70% during the cyclosporine era. Ten adults underwent successful rescue therapy with FK 506 after cardiac rejection refractory to conventional immunotherapy. Side effects of FK 506 were notably few, and the results of the trial are encouraging for the future of the cardiac transplant recipient. © 1992

    Perioperative donor bone marrow infusion augments chimerism in heart and lung transplant recipients

    Get PDF
    Background.: We and others have demonstrated that a low level of donor cell chimerism was present for years after transplantation in tissues and peripheral blood of heart and lung recipients; it was associated, in the latter, with a lower incidence of chronic rejection. To augment this phenomenon, we initiated a trial combining simultaneous infusion of donor bone marrow with heart or lung allotransplantation. Methods.: Between September 1993 and January 1995, 15 nonconditioned patients received either heart (n = 10) or lung (n = 5) allografts concurrently with an infusion of unmodified donor bone marrow (3.0 × 108 cells/kg), and were maintained on an immunosuppressive regimen consisting of tacrolimus and steroids. Results.: There was no complication associated with the infusion of donor bone marrow. Chimerism was detectable in 73% of bone marrow-augmented patients up to the last sample tested. Of the 5 control recipients who did not receive bone marrow infusion, only 1 had detectable chimerism by flow on postoperative day 15, which dwindled to an undetectable level by postoperative day 36. None of the patients had evidence of donor-specific immune modulation by mixed lymphocyte reaction. Conclusions.: The combined infusion of donor bone marrow and heart or lung transplantation, without preconditioning of the recipient, is safe and is associated with an augmentation of donor cell chimerism. © 1995 The Society of Thoracic Surgeons

    Clinical outcomes and healthcare expenditures in the real world with left ventricular assist devices - The CLEAR-LVAD study

    Get PDF
    BACKGROUND: Several distinctly engineered left ventricular assist devices (LVADs) are in clinical use. However, contemporaneous real world comparisons have not been conducted, and clinical trials were not powered to evaluate differential survival outcomes across devices. OBJECTIVES: Determine real world survival outcomes and healthcare expenditures for commercially available durable LVADs. METHODS: Using a retrospective observational cohort design, Medicare claims files were linked to manufacturer device registration data to identify de-novo, durable LVAD implants performed between January 2014 and December 2018, with follow-up through December 2019. Survival outcomes were compared using a Cox proportional hazards model stratified by LVAD type and validated using propensity score matching. Healthcare resource utilization was analyzed across device types by using nonparametric bootstrap analysis methodology. Primary outcome was survival at 1-year and total Part A Medicare payments. RESULTS: A total of 4,195 de-novo LVAD implants were identified in fee-for-service Medicare beneficiaries (821 HeartMate 3; 1,840 HeartMate II; and 1,534 Other-VADs). The adjusted hazard ratio for mortality at 1-year (confirmed in a propensity score matched analysis) for the HeartMate 3 vs HeartMate II was 0.64 (95% CI; 0.52-0.79, p\u3c 0.001) and for the HeartMate 3 vs Other-VADs was 0.51 (95% CI; 0.42-0.63, p \u3c 0.001). The HeartMate 3 cohort experienced fewer hospitalizations per patient-year vs Other-VADs (respectively, 2.8 vs 3.2 EPPY hospitalizations, p \u3c 0.01) and 6.1 fewer hospital days on average (respectively, 25.2 vs 31.3 days, p \u3c 0.01). The difference in Medicare expenditures, conditional on survival, for HeartMate 3 vs HeartMate II was -10,722,p3˘c0.001(17.410,722, p \u3c 0.001 (17.4% reduction) and for HeartMate 3 vs Other-VADs was -17,947, p \u3c 0.001 (26.1% reduction). CONCLUSIONS: In this analysis of a large, real world, United States. administrative dataset of durable LVADs, we observed that the HeartMate 3 had superior survival, reduced healthcare resource use, and lower healthcare expenditure compared to other contemporary commercially available LVADs

    Interpreting neurologic outcomes in a changing trial design landscape: An analysis of HeartWare left ventricular assist device using a hybrid intention to treat population

    Get PDF
    Randomized controlled trials can provide optimal clinical evidence to assess the benefits of new devices, and it is these data that often shape device usage in real-world practice. However, individual clinical trial results sometimes appear discordant for the same device, and alternative devices are sometimes not employed in similar patient populations. To make sound evidence-based decisions, clinicians routinely rely on cross-trial comparisons from different trials of similar but not identical patient populations to assess competing technology when head-to-head randomized comparisons are unavailable

    Effects of donor bone marrow infusion in clinical lung transplantation

    Get PDF
    Background. We have demonstrated that donor cell chimerism is associated with a lower incidence of obliterative bronchiolitis (OB) in lung recipients, and that donor chimerism is augmented by the infusion of donor bone marrow (BM). We herein report the intermediate results of a trial combining the infusion of donor BM and lung transplantation. Methods. Clinical and in vitro data of 26 lung recipients receiving concurrent infusion of donor bone marrow (3.0 to 6.0 x 108 cells/kg) were compared with those of 13 patients receiving lung transplant alone. Results. Patient survival and freedom from acute rejection were similar between groups. Of the patients whose graft survived greater than 4 months, 5% (1 of 22) of BM and 33% (4 of 12) of control patients, developed histologic evidence of OB (p = 0.04). A higher proportion (but not statistically significant) of BM recipients (7 of 10, 70%) exhibited donor-specific hyporeactivity by mixed lymphocyte reaction assays as compared with the controls (2 of 7, 28%). Conclusions. Infusion of donor BM at the time of lung transplantation is safe, and is associated with recipients' immune modulation and a lower rate of obliterative bronchiolitis. (C) 2000 by The Society of Thoracic Surgeons

    The Long-Baseline Neutrino Experiment: Exploring Fundamental Symmetries of the Universe

    Get PDF
    The preponderance of matter over antimatter in the early Universe, the dynamics of the supernova bursts that produced the heavy elements necessary for life and whether protons eventually decay --- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our Universe, its current state and its eventual fate. The Long-Baseline Neutrino Experiment (LBNE) represents an extensively developed plan for a world-class experiment dedicated to addressing these questions. LBNE is conceived around three central components: (1) a new, high-intensity neutrino source generated from a megawatt-class proton accelerator at Fermi National Accelerator Laboratory, (2) a near neutrino detector just downstream of the source, and (3) a massive liquid argon time-projection chamber deployed as a far detector deep underground at the Sanford Underground Research Facility. This facility, located at the site of the former Homestake Mine in Lead, South Dakota, is approximately 1,300 km from the neutrino source at Fermilab -- a distance (baseline) that delivers optimal sensitivity to neutrino charge-parity symmetry violation and mass ordering effects. This ambitious yet cost-effective design incorporates scalability and flexibility and can accommodate a variety of upgrades and contributions. With its exceptional combination of experimental configuration, technical capabilities, and potential for transformative discoveries, LBNE promises to be a vital facility for the field of particle physics worldwide, providing physicists from around the globe with opportunities to collaborate in a twenty to thirty year program of exciting science. In this document we provide a comprehensive overview of LBNE's scientific objectives, its place in the landscape of neutrino physics worldwide, the technologies it will incorporate and the capabilities it will possess.Comment: Major update of previous version. This is the reference document for LBNE science program and current status. Chapters 1, 3, and 9 provide a comprehensive overview of LBNE's scientific objectives, its place in the landscape of neutrino physics worldwide, the technologies it will incorporate and the capabilities it will possess. 288 pages, 116 figure

    Search for the Standard Model Higgs Boson with the OPAL Detector at LEP

    Full text link
    This paper summarises the search for the Standard Model Higgs boson in e+e- collisions at centre-of-mass energies up to 209 GeV performed by the OPAL Collaboration at LEP. The consistency of the data with the background hypothesis and various Higgs boson mass hypotheses is examined. No indication of a signal is found in the data and a lower bound of 112.7GeV/C^2 is obtained on the mass of the Standard Model Higgs boson at the 95% CL.Comment: 51 pages, 21 figure

    Measurement of the Hadronic Photon Structure Function F_2^gamma at LEP2

    Get PDF
    The hadronic structure function of the photon F_2^gamma is measured as a function of Bjorken x and of the factorisation scale Q^2 using data taken by the OPAL detector at LEP. Previous OPAL measurements of the x dependence of F_2^gamma are extended to an average Q^2 of 767 GeV^2. The Q^2 evolution of F_2^gamma is studied for average Q^2 between 11.9 and 1051 GeV^2. As predicted by QCD, the data show positive scaling violations in F_2^gamma. Several parameterisations of F_2^gamma are in agreement with the measurements whereas the quark-parton model prediction fails to describe the data.Comment: 4 pages, 2 figures, to appear in the proceedings of Photon 2001, Ascona, Switzerlan
    corecore