126 research outputs found

    Changes in spherical aberration after lens refilling with a silicone oil

    Get PDF
    PURPOSE. It may be possible to restore accommodation to presbyopic human eyes by refilling the lens capsular bag with a soft polymer. In the present study, optical changes were measured that occurred in a pig eye model after the refilling of the capsular bag. METHODS. The optical power and spherical aberration in 10 isolated pig lenses were measured under different conditions. They were first determined by using a scanning laser raytracing technique over an effective pupil size of 6 mm. Second, the contours of the anterior and posterior lens surface were photographed, and a mathematical ray-tracing was performed by using a polynomial fit through the digitized surface contours, to determine optical power and spherical aberration. Third. the lenses were refilled with a silicone oil until their preoperative lens thickness was reached, and scanning laser ray-tracing, contour photography, and mathematical ray-tracing were repeated. Comparisons between the measurements were made to determine how the change from a gradient refractive index to a homogeneous refractive index influenced spherical aberration. The influence of the change in lens contour on spherical aberration after lens refilling was also studied. RESULTS. The natural lenses had a higher lens power than the refilled lenses (49.9 +/- 1.5 D vs. 36.8 +/- 1.5 D; P <0.001). Moreover, there was a change in sign from negative spherical aberration before lens refilling (-3.6 D) to positive spherical aberration after lens refilling (7.9 D; P <0.001). The comparison between scanning laser ray-tracing of the natural lens and mathematical ray-tracing of the photographed surface contours of the natural lens to determine the effect of refractive index substitution (i.e., replacement of a gradient refractive index by a homogeneous refractive index) showed a significant change in spherical aberration from -3.6 +/- 2.0 to 11.0 +/- 2.1 D (P <0.001). The change in lens contour did not result in a significant change in spherical aberration (P = 0.08) before and after lens refilling with an equal refractive index. CONCLUSIONS. The lower lens power of refilled pig lenses compared to natural lenses was due to the lower refractive index of the refill material. Refilling pig lenses with the silicone oil used in this study resulted in an increase in spherical aberration. This increase was mainly caused by the change from a gradient refractive index to a homogeneous refractive index. The change in lens curvature after lens refilling did not result in an increase in spherical aberration. The influence of lens refilling on spherical aberration of human lenses must be determined in similar experiments in human eyes

    Polymer refilling of presbyopic human lenses in vitro restores the ability to undergo accommodative changes

    Get PDF
    PURPOSE. Because presbyopia is thought to be accompanied by increased lens sclerosis this study was conducted to investigate whether refilling the capsule of the presbyopic human lens with a soft polymer would restore the ability of the lens to undergo accommodative changes. METHODS. Accommodative forces were applied to natural and refilled lenses by circumferential stretching through the ciliary body and zonular complex. Nine natural lenses and 10 refilled lenses from donors ranging in age from 17 to 60 years were studied. Two refill polymers with a different Young's modulus were used. The lens power was measured by a scanning laser ray-tracing technique, and lens diameter and lens thickness were measured simultaneously while the tension on the zonules was increased stepwise by outward pull on the ciliary body. RESULTS. In the natural lenses the older lenses were not able to undergo power changes with stretching of the ciliary body, whereas in the refilled lenses, all lenses showed power changes comparable to young, natural lenses. The refilled human lenses had a higher lens power than the age-matched natural lenses. The Young's modulus of the polymers influenced the lens power change when measured with the ciliary body diameter increased by 4 Him. CONCLUSIONS. Refilling presbyopic lenses with a soft polymer enabled restoration of lens power changes with mechanical stretching. Because sclerosis of the lens is an important factor in human presbyopia, refilling the lens during lens surgery for cataract could enable restoration of clear vision and accommodation in human presbyopia

    The Radio Variability of the Gravitational Lens PMN J1838-3427

    Full text link
    We present the results of a radio variability study of the gravitational lens PMN J1838-3427. Our motivation was to determine the Hubble constant by measuring the time delay between variations of the two quasar images. We monitored the system for 4 months (approximately 5 times longer than the expected delay) using the Australia Telescope Compact Array at 9 GHz. Although both images were variable on a time scale of a few days, no correlated intrinsic variability could be identified, and therefore no time delay could be measured. Notably, the fractional variation of the fainter image (8%) was greater than that of the brighter image (4%), whereas lensed images of a point source would have the same fractional variation. This effect can be explained, at least in part, as the refractive scintillation of both images due to the turbulent interstellar medium of the Galaxy.Comment: To appear in AJ (8 pages, including 4 figures

    The Course of Quality of Life and Its Predictors in Nursing Home Residents With Young-Onset Dementia

    Get PDF
    OBJECTIVE: To explore the course of quality of life (QoL) and possible resident-related predictors associated with this course in institutionalized people with young-onset dementia (YOD). DESIGN: An observational longitudinal study. SETTING AND PARTICIPANTS: A total of 278 residents with YOD were recruited from 13 YOD special care units in the Netherlands. METHODS: Secondary analyses were conducted with longitudinal data from the Behavior and Evolution in Young-ONset Dementia (BEYOND)-II study. QoL was assessed with proxy ratings, using the Quality of Life in Dementia (QUALIDEM) questionnaire at 4 assessment points over 18 months. Predictors included age, gender, dementia subtype, length of stay, dementia severity, neuropsychiatric symptoms, and psychotropic drug use at baseline. Multilevel modeling was used to adjust for the correlation of measurements within residents and clustering of residents within nursing homes. RESULTS: The total QUALIDEM score (range: 0-111) decreased over 18 months with a small change of 0.65 (95% confidence interval -1.27, -0.04) points per 6 months. An increase in several domains of QoL regarding care relationship, positive self-image, and feeling at home was seen over time, whereas a decline was observed in the subscales positive affect, social relations, and having something to do. Residents with higher levels of QoL and more advanced dementia at baseline showed a more progressive decline in QoL over time. Sensitivity analyses indicated a more progressive decline in QoL for residents who died during the follow-up. CONCLUSION AND IMPLICATIONS: This study shows that although overall QoL in nursing home residents with YOD was relatively stable over 18 months, there were multidirectional changes in the QoL subscales that could be clinically relevant. Higher levels of QoL and more advanced stages of dementia at baseline predicted a more progressive decline in QoL over time. More longitudinal studies are needed to verify factors influencing QoL in YOD

    Single-cell isoform RNA sequencing characterizes isoforms in thousands of cerebellar cells

    Get PDF
    Full-length RNA sequencing (RNA-Seq) has been applied to bulk tissue, cell lines and sorted cells to characterize transcriptomes1–11, but applying this technology to single cells has proven to be difficult, with less than ten single-cell transcriptomes having been analyzed thus far12,13. Although single splicing events have been described for ≤200 single cells with statistical confidence14,15, full-length mRNA analyses for hundreds of cells have not been reported. Single-cell short-read 3′ sequencing enables the identification of cellular subtypes16–21, but full-length mRNA isoforms for these cell types cannot be profiled. We developed a method that starts with bulk tissue and identifies single-cell types and their full-length RNA isoforms without fluorescence-activated cell sorting. Using single-cell isoform RNA-Seq (ScISOr-Seq), we identified RNA isoforms in neurons, astrocytes, microglia, and cell subtypes such as Purkinje and Granule cells, and cell-type-specific combination patterns of distant splice sites6–9,22,23. We used ScISOr-Seq to improve genome annotation in mouse Gencode version 10 by determining the cell-type-specific expression of 18,173 known and 16,872 novel isoforms

    Accommodative lens refilling in rhesus monkeys

    Get PDF
    PURPOSE. Accommodation can be restored to presbyopic human eyes by refilling the capsular bag with a soft polymer. This study was conducted to test whether accommodation, measurable as changes in optical refraction, can be restored with a newly developed refilling polymer in a rhesus monkey model. A specific intra-and postoperative treatment protocol was used to minimize postoperative inflammation and to delay capsular opacification. METHODS. Nine adolescent rhesus monkeys underwent refilling of the lens capsular bag with a polymer. In the first four monkeys (group A) the surgical procedure was followed by two weekly subconjunctival injections of corticosteroids. In a second group of five monkeys (group B) a treatment intended to delay the development of capsular opacification was applied during the surgery, and, in the postoperative period, eye drops and two subconjunctival injections of corticosteroids were applied. Accommodation was stimulated with carbachol iontophoresis or pilocarpine and was measured with a Hartinger refractometer at regular times during a follow-up period of 37 weeks in five monkeys. In one monkey, lens thickness changes were measured with A-scan ultrasound. RESULTS. In group A, refraction measurement was possible in one monkey. In the three other animals in group A, postoperative inflammation and capsular opacification prevented refraction measurements. In group B, the maximum accommodative amplitude of the surgically treated eyes was 6.3 D. In three monkeys the accommodative amplitude decreased to almost 0 D after 37 weeks. In the two other monkeys, the accommodative amplitude remained stable at +/- 4 D during the follow-up period. In group B, capsular opacification developed in the postoperative period, but refraction measurements could still be performed during the whole follow-up period of 37 weeks. CONCLUSIONS. A certain level of accommodation can be restored after lens refilling in adolescent rhesus monkeys. During the follow-up period refraction measurements were possible in all five monkeys that underwent the treatment designed to prevent inflammation and capsular opacification

    Mapping Cosmic Dawn and Reionization: Challenges and Synergies

    Get PDF
    Cosmic dawn and the Epoch of Reionization (EoR) are among the least explored observational eras in cosmology: a time at which the first galaxies and supermassive black holes formed and reionized the cold, neutral Universe of the post-recombination era. With current instruments, only a handful of the brightest galaxies and quasars from that time are detectable as individual objects, due to their extreme distances. Fortunately, a multitude of multi-wavelength intensity mapping measurements, ranging from the redshifted 21 cm background in the radio to the unresolved X-ray background, contain a plethora of synergistic information about this elusive era. The coming decade will likely see direct detections of inhomogenous reionization with CMB and 21 cm observations, and a slew of other probes covering overlapping areas and complementary physical processes will provide crucial additional information and cross-validation. To maximize scientific discovery and return on investment, coordinated survey planning and joint data analysis should be a high priority, closely coupled to computational models and theoretical predictions.Comment: 5 pages, 1 figure, submitted to the Astro2020 Decadal Survey Science White Paper cal

    7.1 T MRI to Assess the Anterior Segment of the Eye

    Get PDF
    PURPOSE. Visualization of the anterior segment and biometric evaluation of the entire crystalline lens pose significant challenges for imaging techniques because of tissue-induced distortion artifacts. The present study was conducted to demonstrate the advantages of high-resolution magnetic resonance imaging (micro-MRI) for visualizing the anterior segment. METHODS. High-resolution MR ocular images were acquired on an ultra-high-field MR unit using a two-channel coil with four coil elements and T(2)-weighted turbo spin echo sequences ex vivo in pig, rabbit, monkey, and human donor eyes and in vivo in rabbits. Tissue heating, reproducibility, and signal-to-noise ratio were investigated in vivo. Monkey eye lens thickness (LT) was also measured using A-scan ultrasonography (US). RESULTS. Anterior segment details of phakic eyes were obtained ex vivo (pig, rabbit, monkey, and human donor eyes) with pixel matrix size 512 x 512 (in-plane resolution 80 x 80 mu m) and in vivo (rabbit eyes) with pixel matrix size 320 x 320 (in-plane resolution 125 x 125 mu m). Complete quantification of lens dimensions as they correlate with the sulcus-sulcus and angle-angle plane can be performed. In LT determinations in monkey eyes, no significant difference was detected between micro-MRI and A-scan US (P > 0.05, Mann-Whitney U test). Biometric analysis of one pseudophakic monkey eye confirmed the absence of relevant distortion artifacts. CONCLUSIONS. Micro-MRI allows ex vivo and in vivo visualization and quantification of the spatial arrangement of the anterior eye segment. Imaging of the retroiridian region, including the entire crystalline lens, overcomes a number of major limitations in the quantitative evaluation of the anterior segment. (Invest Ophthalmol Vis Sci. 2010; 51: 6575-6581) DOI:10.1167/iovs.09-486
    • …
    corecore