525 research outputs found

    Photographs of coronal streamers from a rocket on 9 May 1967

    Get PDF
    Analysis of coronal streamers photographed by white light coronagraphs flown on Aerobee 150 vehicl

    Improved effective mobility extraction in MOSFETs

    Get PDF
    The standard method of extracting carrier effective mobility from electrical measurements on MOSFETs is reviewed and the assumptions implicit in this method are discussed. A novel technique is suggested that corrects for the difference in drain bias during IV and CV measurements. It is further shown that the lateral field and diffusion corrections, which are both commonly neglected, in fact cancel. The effectiveness of the proposed technique is demonstrated by application to data measured on a quasi-planar SOI finFET at 300 K and 4 K

    A Review of the Dose Justification of Phase 3 Trials to Regulatory Authorities for Drugs Intended for the Treatment of Type 2 Diabetes in Europe

    Get PDF
    Aims: Cardiovascular outcome trials with anti-diabetic drugs suggest that additional cardiovascular benefit can be achieved independent of improving glycaemic control. Nonetheless, dose selection of anti-diabetic drugs is typically based solely on glycaemic effects. We evaluated whether off-target drug effects are currently considered for dose justification to regulatory agencies. Methods: In the European Union, anti-diabetic drugs are registered by the European Medicines Agency. We extracted available information regarding dose selection from public assessment reports and marketing application dossiers. Descriptive statistics were used to summarise the extracted information. Results: In total, 14 drugs of three drug classes were included; sodium-glucose co-transporter-2 inhibitors (n = 4), dipeptidyl peptidase-4 inhibitors (n = 4) and glucagon-like peptide-1 receptor agonists (n = 6). For these drugs, 21 dose-finding trials were submitted including results of multiple off-target effects, of which body weight (n = 18) and low-density lipoprotein cholesterol (n = 14) were most frequently reported. Dose-response curves for off-target effects appeared to be different compared to the glycaemic dose-response curve. Glycated hemoglobin (100%) and fasting plasma glucose (42.9%), were used most frequently for the dose justification, but generally off-target effects (<25%) were not. Conclusions: Dose justification to regulatory authorities was mainly based on glycaemic effects. The dose-response relationship for the off-target effects did not necessarily follow the dose-response relationship of the on-target effects suggesting that selection of the optimal anti-diabetic dose could benefit from including off-target effects in the dose selection process as well

    Considerable interlaboratory variation in PD-L1 positivity in a nationwide cohort of non-small cell lung cancer patients

    Get PDF
    Objectives: Immunohistochemical expression of programmed death-ligand 1 (PD-L1) is used as a predictive biomarker for prescription of immunotherapy to non-small cell lung cancer (NSCLC) patients. Accurate assessment of PD-L1 expression is therefore crucial. In this study, the extent of interlaboratory variation in PD-L1 positivity in the Netherlands was assessed, using real-world clinical pathology data. Materials and Methods: Data on all NSCLC patients in the Netherlands with a mention of PD-L1 testing in their pathology report from July 2017 to December 2018 were extracted from PALGA, the nationwide network and registry of histo- and cytopathology in the Netherlands. PD-L1 positivity rates were determined for each laboratory that performed PD-L1 testing, with separate analyses for histological and cytological material. Two cutoffs (1% and 50%) were used to determine PD-L1 positivity. Differences between laboratories were assessed using funnel plots with 95% confidence limits around the overall mean. Results: 6,354 patients from 30 laboratories were included in the analysis of histology data. At the 1% cutoff, maximum interlaboratory variation was 39.1% (32.7%-71.8%) and ten laboratories (33.3%) differed significantly from the mean. Using the 50% cutoff, four laboratories (13.3%) differed significantly from the mean and maximum variation was 23.1% (17.2%-40.3%). In the analysis of cytology data, 1,868 patients from 23 laboratories were included. Eight laboratories (34.8%) differed significantly from the mean in the analyses of both cutoffs. Maximum variation was 41.2% (32.2%-73.4%) and 29.2% (14.7%-43.9%) using the 1% and 50% cutoffs, respectively. Conclusion: Considerable interlaboratory variation in PD-L1 positivity was observed. Variation was largest using the 1% cutoff. At the 50% cutoff, analysis of cytology data demonstrated a higher degree of variation than the analysis of histology data

    Exposure and response analysis of aleglitazar on cardiovascular risk markers and safety outcomes:An analysis of the AleCardio trial

    Get PDF
    Aims The AleCardio trial aimed to characterize the efficacy and safety of peroxisome proliferator-activated receptor-alpha gamma agonist aleglitazar in patients with type 2 diabetes mellitus and acute coronary syndrome. The trial terminated early because of futility and safety signals. We evaluated whether the safety signals could be attributed to increased exposure to aleglitazar. Materials and Methods The AleCardio trial enrolled 7226 patients to receive aleglitazar 150 mu g or matching placebo on top of standard care. A population pharmacokinetic analysis was conducted in a pharmacokinetic substudy to identify covariates that explained interindividual variability in exposure. Subsequently, the effect of these covariates on surrogate and clinical outcomes was assessed in the full patient population. Results Concomitant administration of clopidogrel was identified as a covariate that influenced the apparent clearance of aleglitazar. Patients using clopidogrel had a mean predicted area under the plasma-concentration-time curve (AUC(0-24)) of 174.7 ng h/mL (SD: +/- 112.9 ng h/mL) versus 142.2 ng h/mL (SD: +/- 92.6 ng h/mL) in patients without clopidogrel. The effect of aleglitazar compared with placebo on HbA1c, haemoglobin, serum creatinine and adiponectin was modified by concomitant clopidogrel use (P for interaction 0.007, 0.002
    corecore