130 research outputs found

    Flame spread over thin hollow cylindrical fuels in microgravity

    Full text link
    This work presents experimental study on opposed flow flame spread over thin hollow cylindrical cellulosic fuel of diameters varying from 10 mm to 49 mm in microgravity environment. To understand the effect of flow and geometry on flame spread, experiments are conducted in low convective opposed flow conditions ranging from 10 cm/s to 30 cm/s for both hollow cylindrical and planar fuels at oxygen concentration of 21% and 1 atm pressure. In the microgravity environment the flame length and the flame spread rate are seen to increase with increase in hollow cylindrical fuel diameter over the flow range studied here. The flame spread rate exhibited a non-monotonic trend with flow speed, for flow of large diameter whereas a monotonic increasing trend is noted for small diameters. The flame spread rate over hollow cylindrical fuel is noted to be higher or at most equal compared to planar fuels over the matrix of experiments conducted in this study. A simplified analysis is carried out to arrive at an expression for flame spread rate over thin hollow cylindrical fuels. The analysis shows that the radiation heat transfer from the hot char to the inner surface of hollow virgin fuel dictates flame spread rate trend with fuel diameter of the hollow cylindrical fuels. Higher overall equivalence ratio in the inner section of the hollow fuels is responsible for higher char length in hollow fuels and also influence the flame spread rate for smaller fuel diameters.Comment: 40 pages, 14 figure

    Altered balance of inhibitory and active Fc gamma receptors in murine autoimmune glomerulonephritis

    Get PDF
    Mag is an MRL-derived glomerulonephritis susceptibility locus that includes the Fcgr2b and Fcgr3 genes encoding the inhibitory Fc gamma receptor IIB (FcγRIIB) and active FcγRIII, respectively. We measured changes in gene balance in three B6.MRLc1 congenic mouse strains containing the 82-86, 92–100 and 100 cM regions of the MRL chromosome 1. We found that only the strain that has 92-100 (which includes Fcgr loci) developed glomerulonephritis. These congenic mice had splenomegaly, elevated blood urea nitrogen, anti-dsDNA antibodies and higher urinary albumin excretion compared to the parental strain C57BL/6(B6). Prior to the development of glomerulonephritis, large CD3- (T cell) and B220- (B cell) positive areas were identified in the spleens of B6.MRLc1(92–100) mice. Both Fc receptors were found in mesangial and dendritic cells; important sites of immune-complex clearance and antigen presentation. The FcγRIII-positive areas were more prominent in the congenic strain. Fcgr2b mRNA was lower in the B6.MRLc1(92–100) kidney and spleen than in those organs of the B6 mice while Fcgr3 expression and the Fcgr3 to Fcgr2b mRNA ratio was higher in the congenic strain kidneys, spleen and thymus than in those of the B6 prior to and at an early stage of glomerulonephritis. We conclude that the imbalance of inhibitory and active Fc gamma receptors influences the pathogenesis of glomerulonephritis

    JOA Back Pain Evaluation Questionnaire: initial report

    Get PDF
    AbstractBackgroundThere is no widely accepted objective evaluation for lumbar spine disorders. New outcome measures should be patient-oriented and should measure symptoms and self-reported functional status in multiple dimensions. The aim of this study was to identify items to be included in the disease-specific quality of life (QOL) questionnaire for the assessments of patients with lumbar spine disorders.MethodsThe draft of the QOL questionnaire that consisted of a total of 60 items, including 24 items derived from the Japanese version of the Roland Morris Disability Questionnaire (RDQ) and 36 items derived from the Japanese version of Short Form 36 (SF-36), were administered to patients and controls. After obtaining written informed consent, the following data were collected from the patient group (n = 328) and the control group (n = 213): (1) background characteristics, including age, diagnosis, Japanese Orthopaedic Association (JOA) score, and finger to floor distance; (2) responses to the questionnaire; (3) the identification rate by discrimination analysis to select the candidates for adoption and by adopting explanatory variables. The items to be excluded were determined by examining the explanatory variables, which were selected after the discrimination analysis, by setting the candidate to-be-excluded items as an objective variable.ResultsBased on the distribution of the responses, two items, RDQ-15 and RDQ-19, were excluded. From the results of the correlation coefficient calculation for each question in the patient group, 33 items were excluded and 27 candidate items were adopted. Based on the adoption explanatory variable used in the discrimination analysis, 25 of the 27 candidate items for adoption were accepted.ConclusionsThis study identified the 25 specific questionnaire items that should be included in the questionnaire to evaluate QOL of patients with various lumbar spine disorders

    Japanese Orthopaedic Association Cervical Myelopathy Evaluation Questionnaire (JOACMEQ): Part 2. Endorsement of the alternative item

    Get PDF
    AbstractBackgroundA new self-administered questionnaire as an outcome measure for patients with cervical myelopathy was drawn up in Part 1 (Japanese Orthopaedic Association Cervical Myelopathy Evaluation Questionnaire, JOACMEQ). Because a question with regard to driving a car (C-41) was not suitable for this patient group, the authors composed an alternative question related to neck motion (C-41-2). The purposes of the present study were to perform a secondary survey on patients with cervical myelopathy and to statistically analyze the responses to validate the JOACMEQ, and also to determine if it was possible to convert item C-41 to the alternative question.MethodsA member of the Subcommittee on Low Back Pain and Cervical Myelopathy Evaluation from each hospital administered the questionnaire to more than 50 patients with cervical myelopathy in each hospital. The questionnaire consisted of 25 questions, 24 of which were extracted in the primary survey. The authors statistically examined whether it was possible to convert question C-41 to C-41-2.ResultsThree hundred and sixty-eight patients with cervical myelopathy were enrolled in the present study. No questions elicited no answer or “I am not sure” in more than 5% of patients except question C-41. There were no questions that the patients answered with difficulty. There was no tendency that was concentrated on one option as an answer to questions. There was a high correlation between questions C-41 and C-41-2. Spearman’s correlation coefficient and κ value showed that there was high coincidence between the two questions C-41 and C-41-2. It is possible to convert the question C-41 to the alternative question C41-2.ConclusionThe questionnaire has sufficient reliability for clinical use. It is possible that the JOACMEQ will prevail and become a global standard to evaluate outcomes in patients with cervical myelopathy

    Status Report of Neutral Kaon photo-production study using Neutral Kaon Spectrometer 2 (NKS2) at LNS-Tohoku(I. Nuclear Physics)

    Get PDF
    The approach described in this paper uses an array of Field Programmable Gate Array (FPGA) devices to implement a fault tolerant hardware system that can be compared to the running of fault tolerant software on a traditional processor. Fault tolerance is achieved is achieved by using FPGA with on the fly partial programmability feature. Major considerations while mapping to the FPGA includes the size of the area to be mapped and communication issues related to their communication. Area size selection is compared to the page size selection in Operating System Design. Communication issues between modules are compared to the software engineering paradigms dealing with module coupling, fan-in, fan-out and cohesiveness. Finally, the overhead associated with the downloading of the reconfiguration files is discussed

    Japanese Orthopaedic Association Back Pain Evaluation Questionnaire. Part 3. Validity study and establishment of the measurement scale: Subcommittee on Low Back Pain and Cervical Myelopathy Evaluation of the Clinical Outcome Committee of the Japanese Orthopaedic Association, Japan

    Get PDF
    AbstractBackgroundThe Japanese Orthopaedic Association decided to revise the JOA score for low back pain and to develop a new outcome measure. In February 2002, the first survey was performed with a preliminary questionnaire consisting of 60 evaluation items. Based on findings of that survey, 25 items were selected for a draft of the JOA Back Pain Evaluation Questionnaire (JOABPEQ). The second survey was performed to confirm the reliability of the draft questionnaire. This article further evaluates the validity of this questionnaire and establishes a measurement scale.MethodsThe subjects of this study consisted of 355 patients with low back disorders of any type (201 men, 154 women; mean age 50.7 years). Each patient was asked to fill in a self-administered questionnaire. Superficial validity was checked in terms of the completion rate for filling out the entire questionnaire. Factor analysis was then performed to evaluate the validity of the questionnaire and establish a measurement scale.ResultsAs a result of the factor analysis, 25 items were categorized into five factors. The factors were named based on the commonality of the items: social function, mental health, lumbar function, walking ability, and low back pain. To establish a measurement scale for each factor, we determined the coefficient for each item so the difference between the maximum factor scores and minimum factor scores was approximately 100. We adjusted the formula so the maximum for each factor score was 100 and the minimum was 0.ConclusionsWe confirmed the validity of the JOA Back Pain Evaluation Questionnaire and est ablished a measurement scale

    Structural basis for channel conduction in the pump-like channelrhodopsin ChRmine

    Get PDF
    新規光駆動型イオンチャネルの構造解明と高性能分子ツールの創出 --神経科学に光を当てる--. 京都大学プレスリリース. 2022-02-03.ChRmine, a recently discovered pump-like cation-conducting channelrhodopsin, exhibits puzzling properties (large photocurrents, red-shifted spectrum, and extreme light sensitivity) that have created new opportunities in optogenetics. ChRmine and its homologs function as ion channels but, by primary sequence, more closely resemble ion pump rhodopsins; mechanisms for passive channel conduction in this family have remained mysterious. Here, we present the 2.0 Å resolution cryo-EM structure of ChRmine, revealing architectural features atypical for channelrhodopsins: trimeric assembly, a short transmembrane-helix 3, a twisting extracellular-loop 1, large vestibules within the monomer, and an opening at the trimer interface. We applied this structure to design three proteins (rsChRmine and hsChRmine, conferring further red-shifted and high-speed properties, respectively, and frChRmine, combining faster and more red-shifted performance) suitable for fundamental neuroscience opportunities. These results illuminate the conduction and gating of pump-like channelrhodopsins and point the way toward further structure-guided creation of channelrhodopsins for applications across biology

    Japanese Orthopaedic Association Cervical Myelopathy Evaluation Questionnaire (JOACMEQ): part 4. Establishment of equations for severity scores: Subcommittee on low back pain and cervical myelopathy, evaluation of the clinical outcome committee of the Japanese Orthopaedic Association

    Get PDF
    AbstractBackgroundThe project to develop a new Japanese Orthopaedic Association (JOA) score rating system for low back disorders, the JOA Back Pain Evaluation Questionnaire (JOABPEQ), is currently in progress. Part 1 of the study selected 25 “candidate” items for use on the JOABPEQ. The purpose of this current Part 2 of the study was to verify the reliability of the questionnaire.MethodsA total of 161 patients with low-back disorders of any type participated in the study. Each patient was interviewed twice at an interval of 2 weeks using the same questionnaire. The reliability of the questionnaire was evaluated by determining the extension of the kappa and weighted kappa coefficients.ResultsBoth kappa and weighted kappa were more than 0.50 for all but one item, which was 0.48. The lower 95% confidence interval exceeded 0.4 in all but two items, which was 0.39. This implied that the test-retest reliability of JOABPEQ was acceptable as a measure of outcome.ConclusionsThe tentative questionnaire of the JOABPEQ with 25 items was confirmed to be reliable enough to describe the quality of life of patients who suffer low back disorders
    corecore