25 research outputs found

    Long-term effects of a modified, low-protein infant formula on growth and body composition:Follow-up of a randomized, double-blind, equivalence trial

    Get PDF
    Background & aim: High protein intake in early life is associated with an increased risk of childhood obesity. Feeding a modified lower-protein (mLP) infant formula (1.7 g protein/100 kcal) until the age of 6 months is safe and supports adequate growth. The aim of the present study is to assess longer-term anthropometry with BMI at 1 and 2 years as primary outcome parameter and body composition in children fed mLP formula. Methods: Healthy term-born infants received mLP or control formula (CTRL) (2.1 g protein/100 kcal) until 6 months of age in a double-blinded RCT. A breast-fed (BF) group served as a reference. Anthropometry data were obtained at 1 and 2 years of age. At the age of 2 years, body composition was measured with air-displacement plethysmography. Groups were compared using linear mixed model analysis. Results: At 1 and 2 years of age, anthropometry, including BMI, and body composition did not differ between the formula groups (n = 74 mLP; n = 69 CTRL). Compared to the BF group (n = 51), both formula-fed groups had higher z scores for weight for age, length for age, waist circumference for age, and mid-upper arm circumference for age at 1 year of age, but not at 2 years of age (except for z score of weight for age in the mLP group). In comparison to the BF group, only the mLP group had higher fat mass, fat-free mass, and fat mass index. However, % body fat did not differ between feeding groups. Conclusions: In this follow-up study, no significant differences in anthropometry or body composition were observed until 2 years of age between infants fed mLP and CTRL formula, despite the significantly lower protein intake in the mLP group during the intervention period. The observed differences in growth and body composition between the mLP group and the BF reference group makes it necessary to execute new trials evaluating infant formulas with improved protein quality together with further reductions in protein content. Clinical Trial Registry: This trial was registered in the Dutch Trial Register (Study ID number NTR4829, trial number NL4677). https://www.trialregister.nl/trial/4677

    Perspective:Moving Toward Desirable Linoleic Acid Content in Infant Formula

    Get PDF
    Infant formula should provide the appropriate nutrients and adequate energy to facilitate healthy infant growth and development. If conclusive data on quantitative nutrient requirements are not available, the composition of human milk (HM) can provide some initial guidance on the infant formula composition. This paper provides a narrative review of the current knowledge, unresolved questions, and future research needs in the area of HM fatty acid (FA) composition, with a particular focus on exploring appropriate intake levels of the essential FA linoleic acid (LA) in infant formula. The paper highlights a clear gap in clinical evidence as to the impact of LA levels in HM or formula on infant outcomes, such as growth, development, and long-term health. The available preclinical information suggests potential disadvantages of high LA intake in the early postnatal period. We recommend performing well-designed clinical intervention trials to create clarity on optimal levels of LA to achieve positive impacts on both short-term growth and development and long-term functional health outcomes

    Early-Life Metabolic and Hormonal Markers in Blood and Growth until Age 2 Years:Results from a Randomized Controlled Trial in Healthy Infants Fed a Modified Low-Protein Infant Formula

    Get PDF
    Background: High protein intake in early life is associated with an increased risk of childhood obesity. Dietary protein intake may be a key mechanistic modulator through alterations in endocrine and metabolic responses. Objective: We aimed to determine the impact of different protein intake of infants on blood metabolic and hormonal markers at the age of four months. We further aimed to investigate the association between these markers and anthropometric parameters and body composition until the age of two years. Design: Term infants received a modified low-protein formula (mLP) (1.7 g protein/100 kcal) or a specifically designed control formula (CTRL) (2.1 g protein/100 kcal) until 6 months of age in a double blinded RCT. The outcomes were compared with a breast-fed (BF) group. Glucose, insulin, leptin, IGF-1, IGF-BP1, -BP2, and -BP3 levels were measured at the age of 4 months. Anthropometric parameters and body composition were assessed until the age of 2 years. Groups were compared using linear regression analysis. Results: No significant differences were observed in any of the blood parameters between the formula groups (n = 53 mLP; n = 44 CTRL) despite a significant difference in protein intake. Insulin and HOMA-IR were higher in both formula groups compared to the BF group (n = 36) (p < 0.001). IGF-BP1 was lower in both formula groups compared to the BF group (p < 0.01). We found a lower IGF-BP2 level in the CTRL group compared to the BF group (p < 0.01) and a higher IGF-BP3 level in the mLP group compared to the BF group (p = 0.03). There were no significant differences in glucose, leptin, and IGF-1 between the three feeding groups. We found specific associations of all early-life metabolic and hormonal blood parameters with long-term growth and body composition except for IGF-1. Conclusions: Reducing protein intake by 20% did not result in a different metabolic profile in formula-fed infants at 4 months of age. Formula-fed infants had a lower insulin sensitivity compared to breast-fed infants. We found associations between all metabolic and hormonal markers (except for IGF-1) determined at age 4 months and growth and body composition up to two years of age

    A modified low-protein infant formula supports adequate growth in healthy, term infants:a randomized, double-blind, equivalence trial

    Get PDF
    Background: A high protein intake in early life is associated with a risk of obesity later in life. The essential amino acid requirements of formula-fed infants have been reassessed recently, enabling a reduction in total protein content and thus in protein intake. Objectives: We aimed to assess the safety of an infant formula with a modified amino acid profile and a modified low-protein (mLP) content in healthy term-born infants. Outcomes were compared with a specifically designed control (CTRL) infant formula. Methods: In this double-blind, randomized controlled equivalence trial, infants received either mLP (1.7 g protein/100 kcal; n = 90) or CTRL formula (2.1 g protein/100 kcal; n = 88) from enrollment (age ≤ 45 d) to 6 mo of age. A breastfed group served as a reference (n = 67). Anthropometry and body composition were determined at baseline, 17 wk (including safety blood parameters), and 6 mo of age. The primary outcome was daily weight gain from enrollment up until the age of 17 wk (at an equivalence margin of ±3.0 g/d). Results: Weight gain from baseline (mean ± SD age: 31 ± 9 d) up to the age of 17 wk was equivalent between the mLP and CTRL formula groups (27.9 and 28.8 g/d, respectively; difference:-0.86 g/d; 90% CI:-2.36, 0.63 g/d). No differences in other growth parameters, body composition, or in adverse events were observed. Urea was significantly lower in the mLP formula group than in the CTRL formula group (-0.74 mmol/L; 95% CI:-0.97,-0.51 mmol/L; P < 0.001). Growth rates, fat mass, fat-free mass, and several essential amino acids were significantly higher in both formula groups than in the breastfed reference group. Conclusions: Feeding an infant formula with a modified amino acid profile and a lower protein content from an average age of 1 mo until the age of 6 mo is safe and supports an adequate growth, similar to that of infants consuming CTRL formula. This trial was registered at www.trialregister.nl as Trial NL4677

    Relationship of parental characteristics and feeding practices to overweight in infants and young children in Beijing, China

    Get PDF
    Background: Childhood obesity has become a major public health problem in many countries. To explore the risk factors of overweight in infants and young children might be helpful in developing an early overweight intervention strategy. Objective: To assess the prevalence of overweight and the relationship of parental characteristics and feeding practices to overweight in infants and young children in Beijing, China. Design: Data on weight and length/height were collected on 4654 children aged 1–35 months in twelve communities in Beijing from a cross-sectional study. Overweight was defined as weight-for-length/height $2SD above the median of the WHO reference. Two hundred and fifteen families with overweight children and 215 families with normal-weight children were interviewed using a questionnaire to obtain feeding practices. Results: The overall prevalence of overweight was 4?7%. Both parental overweight and low parental education were significantly higher among overweight than normal-weight children. The total energy intake was significantly higher in overweight than in normal-weight children at 12–35 months of age. Compared with normal-weight children, significantly fewer overweight children were breastfed for at least 4 months. Overweight children were also more likely to have been introduced to infant formula and semi-solid foods during the first 4 months. Conclusion: Early prevention strategies should include feeding practices identified as putting children at risk of obesity. These include early cessation of breast-feeding and premature introduction of other foods

    Relationship of parental characteristics and feeding practices to overweight in infants and young children in Beijing, China

    No full text
    <p>Overweight parents with low education were more likely to have overweight children (under 3 years old) in Beijing study. Breastfeeding for at least 4 months was protective, especially when formula and solid foods were not given at the same time. </p
    corecore