271 research outputs found

    "True" as Ambiguous

    Get PDF
    In this paper, I argue (a) that the predicate “true” is ambiguously used to express a deflationary and a substantial concept of truth and (b) that the two concepts are systematically related in that substantial truths are deflationary truths of a certain kind. Claim (a) allows one to accept the main insights of deflationism but still take seriously, and participate in, the traditional debate about the nature of truth. Claim (b) is a contribution to that debate. The overall position is not new and it has previously been defended by supervaluationists about vagueness. However, the position is here motivated in a new, independent way, and an explanation is offered why some uses of “true” do not seem to require disambiguation

    Emergent endovascular treatment options for thoracoabdominal aortic aneurysm

    Get PDF
    For a long time, parallel grafting, physician-modified endografts, and, more recently, in situ fenestration were the only go-to endovascular options for ruptured thoracoabdominal aortic aneurysm, offered mixed results, and depended mainly on the operator's and center's experience. As custom-made devices have become an established endovascular treatment option for elective thoracoabdominal aortic aneurysm, they are not a viable option in the emergency setting, as endograft production can take up to 4 months. The development of off-the-shelf (OTS) multibranched devices with a standardized configuration has allowed the treatment of ruptured thoracoabdominal aortic aneurysm with emergent branched endovascular procedures. The Zenith t-Branch device (Cook Medical) was the first readily available graft outside the United States to receive the CE mark (in 2012) and is currently the most studied device for those indications. A new device, the E-nside thoracoabdominal branch endoprosthesis OTS multibranched endograft (Artivion), has been made commercially available, and the GORE EXCLUDER thoracoabdominal branch endoprosthesis OTS multibranched endograft (W. L. Gore and Associates) is expected to be released in 2023. Due to the lack of guidelines on ruptured thoracoabdominal aortic aneurysm, this review summarizes the available treatment options (ie, parallel grafts, physician-modified endografts, in situ fenestrations, and OTS multibranched devices), compares the indications and contraindications, and points out the evidence gaps that should be filled in the next decade

    Early Experience With a Novel Dissection-Specific Stent-Graft to Prevent Distal Stent-Graft-Induced New Entry Tears After Thoracic Endovascular Repair of Chronic Type B Aortic Dissections

    Get PDF
    Background: The aim was to report short and mid-term outcomes of a novel, investigational, dissection-specific stent-graft (DSSG), specifically designed to address the features of chronic type B aortic dissection (CTBAD) and reduce the risk of distal stent-graft-induced new entry tears (dSINE). Materials and Methods: A retrospective single center cohort study of all patients undergoing TEVAR with the DSSG for CTBAD from January 1, 2017 to January 31, 2020. The DSSG, which is a modified stent-graft based on the Cook Zenith Alpha Thoracic platform, has no proximal barbs, and a customized longer body length with substantial taper. The second and third distal Z-stents are sited internally to avoid any contact of the metal skeleton with the dissection membrane and have reduced radial force, while the most distal stent was removed creating a distal 30 mm unsupported Dacron graft. Results: Sixteen patients (13 males, 3 females) with a median age of 66 years (range 31–79 years) underwent elective TEVAR of CTBAD using the DSSG. Six patients (38%) had an underlying connective tissue disorder. The median tapering was 10 mm (range 4 mm–21 mm) and median length 270 mm (range 210–380 mm). Technical success was achieved in all but one case (96%). One patient died within 30 days, due to retrograde type A dissection with cardiac tamponade. The 30-day rate of stroke, spinal cord ischemia, and re-interventions was 0%. After median imaging follow-up time of 17 months (range 1–31 months), one patient developed a dSINE 4 months after the index procedure. After median survival follow-up of 23 months (range 2–35 months), one late death occurred due to traumatic brain injury, while no aortic-related death occurred during follow-up. Complete false lumen (FL) thrombosis was achieved in 9 patients while the remaining 6 showed partial FL thrombosis. No instances of diameter increase at the level oftreated aortic segment were noted with serial measurements showing either stable (n = 7) or decreased (n = 8) maximal transverse diameter. Conclusions: Use of a novel DSSG with low radial force for TEVAR in the setting of CTBAD is safe and feasible. This early real-world experience shows promising mid-term effectiveness with low rates of dSINE or unplanned re-interventions and satisfactory aortic remodeling during follow-up. Longer follow-up is needed, however, before any firm conclusions can be drawn

    The new educational project Televascular Games during the Coronavirus Disease 2019 pandemic

    Get PDF
    Objective: To report methodology and first-year results of a new educational project called Televascular Games,” which took place during coronavirus disease 2019 pandemic. Methods: Complex aneurysmal aortic disease was discussed during a 2-hour competition webinar, according to three modalities. (1) Planning case competition (PCC): Two to four preoperative computed tomography angiography (CTA) scans of an already performed selected case were submitted for the competition. CTA scans were uploaded anonymously, without any reference to the center or the surgeon who performed the case. The competitor had to prepare a presentation of how he or she would have diagnosed, sized, planned, treated, and followed up the case, of the medical therapy and of the bail-out maneuvers. (2) Challenging case competition (CCC): The competitor elaborates a presentation of an already treated case concerning an aortic topic and discusses sizing, planning, treatment, possible bail-out maneuvers and obtained results. For the CCC and PCC, the competitors with the best score were preselected to present and discuss their plan during the webinars. (3) Quiz competition: Two to six CTA scans of already performed selected aortic cases were submitted for the competition. A quiz with multiple choice questions was answered by the competitors. The top four competitors were selected for the webinars and then they discussed the cases during the webinar. Finally, at the end of the case discussion, the effective case resolution and follow-up were shown. A final winner was voted via televoting, based on six preestablished criteria. The project was endorsed by different national and international societies. Results: Between October 2020 and December 2021, there were 12 Italian and 1 international webinars with 1695 participants overall (mean, 130; range, 86-177). Competitors were 54 years of age (mean, 27 years; range, 22-38 years). Two editions were CCCs, two quiz competitions, and nine PCCs. The reliability of the interobserver sizing of competitors was κ = 0.43 and κ = 0.62 for the proximal and distal sealing measurements respectively and very good (κ = 0.88-0.95) in the evaluation of orientation of the vessels, presence of angulations, calcifications, and thrombus. The sizing discrepancy resulted in a significant variability of the planning (κ = 0.45). The project ranked 9.6 on a 10-point rating scale by all the participants and competitors. Conclusions: The formula of gaming and collegial discussion of aortic cases herein reported has proved valid and attractive during coronavirus disease 2019 pandemic period. The variability of the results on sizing and planning suggested to confer with a second opinion, especially for less experienced surgeons

    Shadow-mask evaporation through monolayer-modified nanostencils

    Get PDF
    Gradual clogging of the apertures of nanostencils used as miniature shadow masks in metal evaporations can be reduced by coating the stencil with self-assembled monolayers (SAM). This is quantified by the dimensions (height and volume) of gold features obtained by nanostencil evaporation as measured by scanning electron microscopy (SEM) and atomic force microscopy (AFM). An increase in material deposition through the apertures by more than 100% can be achieved with SAM-coated stencils, which increases their lifetime

    Reply to Lasersohn, MacFarlane, and Richard

    Full text link

    Custom Made Candy Plug for Distal False Lumen Occlusion in Aortic Dissection: International Experience

    Get PDF
    Objective: To evaluate early and midterm outcomes of the Candy Plug (CP) technique for distal false lumen (FL) occlusion in thoracic endovascular aortic repair for aortic dissection (AD) in a more real world cohort of patients from an international multicentre registry. Methods: A multicentre retrospective study was conducted of all consecutive patients from the contributing centres with subacute and chronic AD treated with the CP technique from October 2013 to April 2020 at 18 centres. Results: A custom made CP was used in 155 patients (92 males, mean age 62 ± 11 years). Fourteen (9%) presented with ruptured false lumen aneurysms. Technical success was achieved in all patients (100%). Clinical success was achieved in 138 patients (89%). The median hospital stay was 7 days (1 – 77). The 30 day mortality rate was 3% (n = 5). Stroke occurred in four patients (3%). Spinal cord ischaemia occurred in three patients (2%). The 30 day computed tomography angiogram (CTA) confirmed successful CP placement at the intended level in all patients. Early complete FL occlusion was achieved in 120 patients (77%). Early (30 day) CP related re-intervention was required in four patients (3%). The early (30 day) stent graft related re-intervention rate was 8% (n = 12). Follow up CTA was available in 142 patients (92%), with a median follow up of 23 months (6 – 87). Aneurysmal regression was achieved in 68 of 142 patients (47%); the aneurysm diameter remained stable in 69 of 142 patients (49%) and increased in five of 142 patients (4%). A higher rate of early FL occlusion was detected in the largest volume centre patients (50 [88%] vs. 70 [71%] from other centres; p = .019). No other differences in outcome were identified regarding volume of cases or learning curve. Conclusion: This international CP technique experience confirmed its feasibility and low mortality and morbidity rates. Aortic remodelling and false lumen thrombosis rates were high and support the concept of distal FL occlusion in AD using the CP technique

    Outcomes of “Anterior Versus Posterior Divisional Branches of the Hypogastric Artery as Distal Landing Zone for Iliac Branch Devices”: The International Multicentric R3OYAL Registry

    Get PDF
    Objective: The aim of this multicentric registry was to assess the outcomes of “anteRior versus posteRior divisional bRanches Of the hYpogastric artery as distAl landing zone for iLiac branch devices (R3OYAL).” Methods: The main exposure of interest for the purpose of this study was the internal iliac artery (IIA) divisional branch (anterior vs posterior) that was used as distal landing zone. Early endpoints included technical success and adverse events. Late endpoints included survival, primary/secondary IIA patency, and IIA branch instability. Results: A total of 171 patients were included in the study, of which 50 received bilateral implantation of iliac branch devices (IBDs). This resulted in a total of 221 incorporated IIAs included in the final analysis, of which 40 were anterior divisional branches and 181 were posterior divisional branches. Technical success was high in both groups (anterior division: 98% vs posterior division: 100%, P =.18). Occurrence of any adverse event was noted in 14% of patients in both groups (P = 1.0). The overall rate of freedom from the composite IBD branch instability did not show significant differences between patients receiving distal landing in the anterior or posterior division of the IIA at 3 years (79% vs 87%, log-rank test =.215). The 3-year estimates of IBD patency were significantly lower in patients who received distal landing in the anterior divisional branch than those who received distal landing in the posterior divisional branch (primary patency: 81% vs 96%, log-rank test =.009; secondary patency: 81% vs 97%, log-rank test <.001). Conclusions: The use of the anterior or posterior divisional branches of the IIA as distal landing zone for IBD implantation shows comparable profiles in terms of immediate technical success, perioperative safety, and side-branch instability up to 3 years. However, IBD patency at 3 years was higher when the distal landing zone was achieved within the posterior divisional branch of the IIA. Clinical Impact: The results from this large multicentric registry confirm that use of the anterior or posterior divisional branches of the internal iliac artery (IIA) as distal landing zone for implantation of iliac branch devices (IBD) shows comparable profiles of safety and feasibility, thereby allowing to extend the indications for endovascular repair of aorto-iliac aneurysms to cases with unsuitable anatomy within the IIA main trunk. Although mid-term rates of device durability and branch instability seem to be similar, the rates of primary and secondary IBD patency at three years was favored when the distal landing zone was achieved in the posterior divisional branch of the IIA

    Multicentre International Registry of Open Surgical Versus Percutaneous Upper Extremity Access During Endovascular Aortic Procedures

    Get PDF
    Objective: To investigate access failure (AF) and stroke rates of aortic procedures performed with upper extremity access (UEA), and compare results of open surgical vs. percutaneous UEA techniques with closure devices. Methods: A physician initiated, multicentre, ambispective, observational registry (SUPERAXA - NCT04589962) was carried out of patients undergoing aortic procedures requiring UEA, including transcatheter aortic valve replacement, aortic arch, and thoraco-abdominal aortic endovascular repair, pararenal parallel grafts, renovisceral and iliac vessel repair. Only vascular procedures performed with an open surgical or percutaneous (with a suture mediated vessel closure device) UEA were analysed. Risk factors and endpoints were classified according to the Society for Vascular Surgery and VARC-3 (Valve Academic Research Consortium) reporting standards. A logistic regression model was used to identify AF and stroke risk predictors, and propensity matching was employed to compare the UEA closure techniques. Results: Sixteen centres registered 1 098 patients (806 men [73.4%]; median age 74 years, interquartile range 69 – 79 years) undergoing vascular procedures using open surgical (76%) or percutaneous (24%) UEA. Overall AF and stroke rates were 6.8% and 3.0%, respectively. Independent predictors of AF by multivariable analysis included pacemaker ipsilateral to the access (odds ratio [OR] 3.8, 95% confidence interval [CI] 1.2 – 12.1; p =.026), branched and fenestrated procedure (OR 3.4, 95% CI 1.2 – 9.6; p =.019) and introducer internal diameter ≥ 14 F (OR 6.6, 95% CI 2.1 – 20.7; p =.001). Stroke was associated with female sex (OR 3.4, 95% CI 1.3 – 9.0; p =.013), vessel diameter > 7 mm (OR 3.9, 95% CI 1.1 – 13.8; p =.037), and aortic arch procedure (OR 7.3, 95% CI 1.7 – 31.1; p =.007). After 1:1 propensity matching, there was no difference between open surgical and percutaneous cohorts. However, a statistically significantly higher number of adjunctive endovascular procedures was recorded in the percutaneous cohort (p <.001). Conclusion: AF and stroke rates during complex aortic procedures employing UEA are non-negligible. Therefore, selective use of UEA is warranted. Percutaneous access with vessel closure devices is associated with similar complication rates, but more adjunctive endovascular procedures are required to avoid surgical exposure
    • …
    corecore